Cart  |  Contact  |  Help  | 
US and Canada1-888-826-6342
International1-203-359-1660

Portable Temperature/Humidity Data Loggers with Display

OM-70 Series

Portable Temperature and Humidity  Data Loggers with Display | OM-70 Series

$150.00 OM-71

OM-70 Series is rated 4.2 out of 5 by 5.
  • y_2017, m_12, d_12, h_24
  • bvseo_bulk, prod_bvrr, vn_bulk_2.0.3
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_5
  • loc_en_US, sid_OM-70_SERIES, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, net_sdk, 3.1.1.0
  • CLOUD, getAggregateRating, 30ms
  • REVIEWS, PRODUCT
1 year warranty RoHS
  • Compact, Light Weight, Easy-to-Use
  • User Selectable Stop on Memory Full or Memory Rollover for Continuous Recording
  • PC Delayed Start or Pushbutton Recording Control
  • Read Recorded Data on Logger Display
  • Displays Alarm Icon for High/Low Alarm Conditions
  • Nonvolatile EEPROM Memory Retains Data Even if Battery Fails
  • USB Interface for Fast Data Transfer
  • Includes Free Software
Relative Humidity Measurement Instruments - View related products

Description

The OM-70 Series of portable temperature and temperature/humidity data loggers are easy-to use, versatile devices which can be used for a wide range of logging applications including coolers, freezers, greenhouses, museums, laboratories, shipping containers, warehouses, environmental monitoring and food storage.

These data loggers are capable of sampling as fast as once per second or as slow as every 18 hours. Models OM-71 and OM-72 can store a total of 43,344 temperature measurements in memory. Model OM-73 can store a total of 43,344 measurement points for temperature only or 21,672 points of temperature, humidity and dew point. The model OM-74 thermocouple data logger can store 32,638 temperature samples. Easy-to-use Windows software is included with each data logger.

The software is a full-featured program that allows you to set up all data logger functions including sampling rate, logging duration, start mode, logging mode, and high and low temperature alarm values. Once data has been logged, the program then allows you to download data from the logger, plot the data and export the data to an ASCII text or Excel file format for further analysis.

Software Features Include:
• Data summary to read statistics and alarm information in a simplified report format.
• Data listing for tabular view of detailed dates, times and values of recorded data.
• Graph function displays data in clear graphical format.
• Zoom magnifies data with powerful zoom and autoscale functions.
• Autoscale function fits data to the screen or allows user to manually enter their own values.
• Graphical Cursor displays exact data of any point in the graphical display.
• Export data in text or Excel format.
• Print graph or text data with print preview and setup options.
• Logger configuration allows easy set up and launch of data loggers with immediate or delayed start, preferred sample rate, alarm setup, and custom ID.
• Password protected calibration function automatically stores with parameters in device or restores factory defaults. A calibration Window is provided in the software to simplify the calibration procedure.
• Status windows display unique ID of logger, battery voltage, memory used, sample rate, duration, alarm condition and logging status.
• Menu Bar along the top of the screen provides one click access to software functions.

Specifications
OM-71, OM-72, OM-73
Ambient Temperature Measurement Range
(Models OM-71, OM-73):
-20 to 70°C (-4 to 160°F)
External Sensor Temperature Measurement Range
(Model OM-72):
-40 to 70°C (-40 to 160°F)
Storage Temperature: -40 to 77°C (-40 to 170°F)
Temperature Accuracy: ±0.5°C (±1°F), from -17 to 50°C (1 to 122°F)
Temperature Resolution: 0.1°C (0.05°F)
Relative Humidity Range
(Model OM-73):
0 to 99% RH non-condensing
Relative Humidity Accuracy
(Model OM-73):
±2% RH from 10 to 90% RH @ 25°C (77°F)
Relative Humidity Resolution
(Model OM-73):
0.05% RH

OM-74
Display Temperature Resolution:
0.1°C (0.2°F) up to 199.9 °C or °F,
1°C (1°F) above 200 °C or °F
Logged Temperature Resolution: 0.1°C (0.2°F)
Thermocouple Impedance: 50 ? max for specified accuracy
Cold Junction Temperature Accuracy: ± 0.3°C (±0.5°F)
Operating Temperature: -18 to 55°C (0 to 131°F)
Storage Temperature:-30 to 80°C (-20 to 175°F)

GENERAL
Sample Rate:
1 second to 18 hours user selectable
Alarm Settings: Over/under alarm with visual indication
LCD Display: Displays temperature, date, time,
alarm condition recording status and battery condition
Time Accuracy: ±100 ppm @ 24°C (75°F)
Measurement Capacity: OM-71, OM-72, OM-73:
Non-volatile memory; 43,344 samples
for temperature only, or 21,672 samples for temperature,
humidity and dew point (Model OM-73); OM-74; 32,638 temperature samples
Recording Control: Start on button press, immediate after setup,
or at a user specified date and time
Recording Mode: Stop on memory full,
or continuous recording with memory rollover
Minimum System Requirements: 8MB of RAM, 2MB of disk space,
800 x 600 resolution, 1 free USB port
Software Compatibility: Windows XP/Vista/7 and 8 (32-bit and 64-bit)
Interface: USB 2.0
Power: OM-71, OM-72, OM-73: 3 V CR2032 lithium battery (included);
OM-74; 3 AAA batteries (alkaline or lithium)
Battery Life: 3 years (average)
Dimensions:
OM-71, OM-72, OM-73: 6 H x 5.7 W x 1.3 cm D (2.36 x 2.24 x 0.51")
OM-74: 5.7 H x 5.5 W x 3.0 cm D (2.25 x 2.15 x 1.2")
Weight:
OM-71, OM-72, OM-73:
91 g (3.2 oz)
OM-74: 62 g (2.2 oz)
Place Order(Specify Model Number)

What Other People Bought: When you see this icon, click on it to expand a list of products that other people have bought when they purchased this model.

Star

Most Popular Models!

Part Number/ Desc.
Qty
RoHS
Description
Click to expand/minimize a list of what others bought with theOM-71
Customers also bought
OM-71 Star
$150.00
15 In Stock
RoHS compliancy undetermined
Temperature data logger with display
Click to expand/minimize a list of what others bought with theOM-72
Customers also bought
OM-72 Star
$160.00
4 In Stock
RoHS compliancy undetermined
Temperature data logger with display and remote temperature sensor
Click to expand/minimize a list of what others bought with theOM-73
Customers also bought
OM-73 Star
$180.00
More Than 25 In Stock
RoHS compliancy undetermined
Temperature/humidity data logger with display
Click to expand/minimize a list of what others bought with theOM-74
Customers also bought
OM-74 Star
$195.00
More Than 25 In Stock
RoHS compliancy undetermined
Thermocouple data logger with display
  
OM-71-NIST Star
$475.00
Available In 13 Weeks
RoHS compliancy undetermined
Temperature data logger with display and NIST calibration certificate
  
OM-72-NIST Star
$485.00
Available In 13 Weeks
RoHS compliancy undetermined
Temperature data logger with display and remote temperature sensor and NIST calibration certificate
  
OM-73-CAL-3-HU Star
$320.00
Available In 3 Weeks
RoHS compliancy undetermined
NIST traceable calibration certificate for OM-73
  
OM-74-NIST Star
$475.00
Available In 13 Weeks
RoHS compliancy undetermined
Thermocouple data logger with display and NIST calibration certificate
Click to expand/minimize a list of what others bought with theOM-40-BATT-6
Customers also bought
OM-40-BATT-6 Star
Consult Sales  
 
RoHS compliancy undetermined
Replacement 3V lithium battery (box of 6), for OM-71, OM-72 and OM-73
  
CR-2032 Star
$3.10
More Than 25 In Stock
RoHS compliant
Replacement 3V lithium battery for OM-71, OM-72 and OM-73
All amounts shown in USD
Note: Comes complete with Windows software, operator’s manual on CD, USB interface cable and battery.
Ordering Example: (1) OM-72 Temperature data logger with display and remote temperature sensor, $160.00
Rated 4 out of 5 by from Solid Logger (for the most part) I have bought roughly 10 of these over the past 8 years. We use them for monitoring the temperature and humidity of a control room for Concrete testing. For the most part these are solid units. I have had a couple that had the screens go out on them after 5 years or so and the plastic gets discolored when exposed to sunlight. One had the temperature go out and it only lets you calibrate it slightly from the original settings. That said these generally work great with those few exceptions. The program for the PC is easy to use and understand. I will continue to purchase these as needed.
Date published: 2016-03-11
Rated 4 out of 5 by from Good for general monitoring We really like the OM-70 series for monitoring temperature and humidity during our testing. They work well and the software is easy to use. The only issue we have is that they will not stay in calibration in the lower 10 degrees C of the published range and there is no adjustment to correct this. We calibrate them to 10 C above the published low range and they work well there.
Date published: 2017-11-16
Rated 4 out of 5 by from Reliable instrument Have one of this working for more than 4 years in a curing room in the middle of the Mojave desert. No problem at all.
Date published: 2017-09-01
Rated 5 out of 5 by from Temperature data logger We have bought these before. They have lasted many years in extreme environments. Only had to change the battery on one unit once.
Date published: 2017-04-12
Rated 4 out of 5 by from Working as described, trying software with WINE We have been using this to monitor the RH in a glove box. It has been working well for that, 0.1% RH is about 25 ppm H2O in our environment. If you don't need single digit ppm H2O measurements, then this is an inexpensive way to monitor a glovebox. The software runs under WINE (Crossover) in Ubuntu 14.04 GNU/Linux. However, it cannot see the datalogger on the USB port. Web searches suggest that you need to set up a link from the appropriate usb port in /dev to the appropriate COM port the dosdevices directory of the WINE bottle in which the datalogger software is running. It should work that way, but I haven't gotten around to testing it. It turns out we don't need the datalogger function very often, we mainly use it for real-time information. The main improvement I would like to see is documentation of the communication protocol so I can talk to the datalogger directly in a GNU/Linux operating system without using WINE.
Date published: 2016-06-03
  • y_2017, m_12, d_12, h_24
  • bvseo_bulk, prod_bvrr, vn_bulk_2.0.3
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_5
  • loc_en_US, sid_OM-70_SERIES, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, net_sdk, 3.1.1.0
  • CLOUD, getReviews, 3ms
  • REVIEWS, PRODUCT