Cart  |  Contact  |  Help  | 
US and Canada1-888-826-6342
International1-203-359-1660

Your Source for Process Measurement & Control

25 mm (1") Dia. Compact High Performance Fixed Infrared Sensor/Transmitter

OS137A

Compact Infrared Temperature Sensor Transmitter | OS137A
New

Compact Infrared Temperature Sensor Transmitter

See All Models Below

  • bvseo_sdk, net_sdk, 3.1.1.0
  • CLOUD, getAggregateRating, 70ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
1 year warranty CE
  • 3 Temperature Ranges Available:
    OS137A-1: 0 to 100°C (32 to 212°F)
    OS137A-2: -18 to 260°C (0 to 500°F)
    OS137A-3: -18 to 538°C (0 to 1000°F)
  • Sensor and Transmitter Combined
  • Adjustable Emissivity
  • Adjustable Alarm Setpoint and Output
  • Packaged in a 25 mm (1.0") OD by 127 mm (5.0") Long Stainless Steel NEMA 4 (IP65) Rated Housing
  • 10:1 Optical Field of View
  • 4 to 20 mA, 0 to 5 Vdc, 0 to 10 Vdc, 10 mV/Deg, and Type K Thermocouple Outputs Available
Infrared Temperature Measurement Instruments - View related products

Description

The Omega compact high performance industrial infrared sensor/transmitter model OS137A, provides a variety of features and options packaged in a small stainless steel housing. The standard features are adjustable emissivity, 10 to 1 optical field of view, adjustable alarm set point and voltage output to drive external relays, and 6 pre-selected analog outputs that can easily be interfaced to all meters, controllers, data loggers, recorders, computer boards, and PLCs. The unit comes with 2 hex nuts, 1.8 m (6') shielded cable for power and output connections, and an operator’s manual.

Specifications
Temp Range:
    OS137A-1: 0 to 100°C (32 to 212°F)
    OS137A-2: -18 to 260°C (0 to 500°F)
    OS137A-3: -18 to 538°C (0 to 1000°F)
Accuracy: 1.5% rdg or 3.5°F (2°C) whichever is greater
Repeatability: 1% rdg or 2°F (1°C)
Field of View: 10 to 1
Spectral Response: 5.5 to 14 microns
Emissivity: 0.5 to 1.0, adjustable via a single turn pot
Response Time: 150 msec, 0 to 63% of final value
Outputs:
    -MA: 4 to 20 mA
    -V1: 0 to 5 Vdc
    -V2: 0 to 10 Vdc
    -K: K thermocouple
    -MVF: 10 mV/°F
    -MVC: 10 mV/°C
Alarm Output: Voltage, 100 mA drive
Alarm Set Point: 0 to 100 % adj, set via pot
Power: 12 to 24 Vdc @ 50 mA
Operating Temperature:     With No Cooling: 0 to 70°C
    With Water Cooling: 0 to 200°C
    With Air Cooling: 0 to 110°C
Operating Relative Humidity: Less than 95% RH, non-condensing
Housing: Stainless steel, Nema 4 (IP65)
Dimensions: 25.4 OD x 127 mm L (1 x 5")
Weight: 226 g (0.5 lb)
Laser Sighting
Wavelength (Color): 630-670 nm (red)
Operating Distance: Up to 9.1 m (30')
Max Laser Power Output: Less than 1 mW
European Classification: Class 2, EN60825-1/11.2001
FDA Classification: Class II, complies with 21 CFR 1040.10
Laser Beam Diameter: Less than 5 mm
Beam Divergence: Less than 2 mrad
Power Switch: Slide switch on the battery pack
Power Indicator: Red LED
Caution and Certification Label: Located on the head circumference
Aperture and Identification Label: Located on the head circumference
Place Order(Specify Model Number)
Part Number/ Desc.
Qty
Description
OS137A-2-K Star
$352.00
Available In 3 Weeks
 
Infrared transmitter with K thermocouple output over -18 to 260°C (0 to 500°F) range
OS137A-3-K Star
$352.00
Available In 3 Weeks
 
Infrared transmitter with K thermocouple output over -18 to 538°C (0 to 1000°F)
OS137A-1-MV-F Star
$365.00
3 In Stock
 
Infrared transmitter with 10 mV/°F output over 32 to 212°F Range
OS137A-1-MV-C Star
$365.00
Available In 3 Weeks
 
Infrared transmitter with 10 mV/°C output over 0 to 100°C Range
OS137A-1-MA Star
$365.00
Available In 3 Weeks
 
Infrared transmitter with 4 to 20 mA output over 0 to 100°C (32 to 212°F) Range
OS137A-2-MA Star
$352.00
Available In 3 Weeks
 
Infrared transmitter with 4 to 20 mA output over -18 to 260°C (0 to 500°F) range
OS137A-2-V1 Star
$352.00
Available In 3 Weeks
 
Infrared transmitter with 0 to 5 Vdc output over -18 to 260°C (0 to 500°F)
OS137A-3-V2 Star
$352.00
Available In 3 Weeks
 
Infrared transmitter with 0 to 10 Vdc output over -18 to 538°C (0 to 1000°F)
All amounts shown in USD
Note: * Insert “1” for 0 to 100°C (32 to 212°F); Insert “2” for -18 to 260°C (0 to 500°F); Insert “3” for -18 to 538°C (0 to 1000°F).
Comes complete with two mounting nuts and operator’s manual.
To order with longer power/output cable, up to 30 m (100'), add suffix “-(**)FT” to model number, and add an additional cost for each additional foot over 1.8 m (6').
** Specify length in feet.
OS137-LS laser sighting: 1 unit suitable for aligning multiple heads. Used during installation only.

Part Number Builder

Build Your Part Number Below
Option Descriptions:


(1) Temperature Range select from:
-1 for 0 to 100°C (32 to 212°F)
-2 for -18 to 260°C (0 to 500°F)
-3 for -18 to 538°C (0 to 1000°F)

(2) Output select from:
K for Type K thermocouple
MV-F for 10 mV/°F
MV-C for 10 mV/°C
MA for 4 to 20 mA
V1 for 0 to 5 Vdc
V2 for 0 to 10 Vdc
Note: All combinations may not be valid, check spec sheet for valid part numbers.

Product Manuals:

Download Miniature Non-Contact Infrared Temperature Sensor/Transmitter
Download Quick Start Guide OS137A SERIES
  • bvseo_sdk, net_sdk, 3.1.1.0
  • CLOUD, getReviews, 5ms