The FL-6000A Series of general purpose flowmeters is designed to provide economical, accurate flow rate indication for oil and water and can be mounted in any position.
Product Number | Category | Media Type | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Water
|
1.5 to 15 GPM
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Brass, Polyphenylene Sulfide, Ceramic, FKM
|
3500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Dual Scale GPM/LPM
|
|
Meter
|
Oil
|
0.2 to 2 GPM
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic, FKM
|
3500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Dual Scale GPM/LPM
|
|
Meter
|
Oil
|
0.5 to 5 GPM
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic, FKM
|
3500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Dual Scale GPM/LPM
|
|
Meter
|
Oil
|
1 to 10 GPM
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic, FKM
|
3500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Dual Scale GPM/LPM
|
|
Meter
|
Oil
|
1.5 to 15 GPM
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic, FKM
|
3500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Dual Scale GPM/LPM
|
FL7000 flow meters are precisely machined from solid acrylic blocks. They are available in 50, 75, 100, 127, and 250 mm scale lengths with accuracies between 2 and 6%.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Air
|
0.4 to 4 SCFM
|
Not Applicable
|
±6%
|
NPT Female
|
1/4"
|
316 SS, Acrylic, Brass, EPR
|
100 psi
|
38 °C (100 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
Not Applicable
|
0.7 to 7 GPH
|
±6%
|
NPT Female
|
1/4"
|
316 SS, Acrylic, Brass, EPR
|
125 psi
|
54 °C (130 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
Not Applicable
|
1.2 to 12 GPH
|
±6%
|
NPT Female
|
1/4"
|
316 SS, Acrylic, Brass, EPR
|
125 psi
|
54 °C (130 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
Not Applicable
|
2 to 20 GPH
|
±6%
|
NPT Female
|
1/4"
|
316 SS, Acrylic, Brass, EPR
|
125 psi
|
54 °C (130 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
Not Applicable
|
5 to 50 GPH
|
±6%
|
NPT Female
|
1/4"
|
316 SS, Acrylic, Brass, EPR
|
125 psi
|
54 °C (130 °F)
|
Direct Read
|
No
|
The FLMG flow meters feature rugged construction and direct-reading flow rates of air. The units are calibrated at 100 psi pressure, idea for most compressed air applications.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Air
|
6 to 50 SCFM
|
null
|
±4%
|
NPT Female
|
1"
|
Aluminum, Buna, PTFE, SS
|
600 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Not Applicable
|
|
Meter
|
Air
|
6 to 50 SCFM
|
null
|
±4%
|
NPT Female
|
1"
|
Brass, Buna, PTFE, SS
|
600 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Not Applicable
|
|
Meter
|
Air
|
6 to 50 SCFM
|
null
|
±4%
|
NPT Female
|
1"
|
304 SS, FKM, PTFE
|
1,000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Not Applicable
|
|
Meter
|
Air
|
10 to 100 SCFM
|
null
|
±4%
|
NPT Female
|
1"
|
Aluminum, Buna, PTFE, SS
|
600 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Not Applicable
|
|
Meter
|
Air
|
10 to 100 SCFM
|
null
|
±4%
|
NPT Female
|
1"
|
Brass, Buna, PTFE, SS
|
600 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Not Applicable
|
The FL-7000A Series of General purpose flowmeters is designed to provide accurate flowrate indication for oil and water. These flowmeters can be mounted in any position.
Product Number | Category | Media Type | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Oil
|
0.2 to 2 GPM
|
±2%
|
NPT Female
|
3/4"
|
Aluminum, 302 SS, Polyphenylene Sulfide, Ceramic, FKM
|
3500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
|
Meter
|
Oil
|
0.5 to 5 GPM
|
±2%
|
NPT Female
|
3/4"
|
Aluminum, 302 SS, Polyphenylene Sulfide, Ceramic, FKM
|
3500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
|
Meter
|
Oil
|
1 to 10 GPM
|
±2%
|
NPT Female
|
3/4"
|
Aluminum, 302 SS, Polyphenylene Sulfide, Ceramic, FKM
|
3500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
|
Meter
|
Oil
|
2 to 20 GPM
|
±2%
|
NPT Female
|
3/4"
|
Aluminum, 302 SS, Polyphenylene Sulfide, Ceramic, FKM
|
3500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
|
Meter
|
Oil
|
3 to 30 GPM
|
±2%
|
NPT Female
|
3/4"
|
Aluminum, 302 SS, Polyphenylene Sulfide, Ceramic, FKM
|
3500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
The FLMW and FLMH flowmeters can be installed in the fluid line without flow straighteners. The spring-and-piston type assembly protects them against changes in viscosity.
Product Number | Category | Media Type | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Oil
|
0.2 to 2 GPM
|
±2%
|
NPT Female
|
1"
|
Aluminum, SS, Buna, EPR, FKM, Perfluoroelastomer, PTFE-Coated Alnico
|
3500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Not Applicable
|
|
Meter
|
Oil
|
0.2 to 2 GPM
|
±2%
|
NPT Female
|
1"
|
Brass, SS, Buna, EPR, FKM, Perfluoroelastomer, PTFE-Coated Alnico
|
3500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Not Applicable
|
|
Meter
|
Oil
|
0.2 to 2 GPM
|
±2%
|
NPT Female
|
1"
|
304 SS, Buna, EPR, FKM, Perfluoroelastomer, PTFE-Coated Alnico
|
6000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Not Applicable
|
|
Meter
|
Oil
|
0.5 to 5 GPM
|
±2%
|
NPT Female
|
1"
|
Aluminum, SS, Buna, EPR, FKM, Perfluoroelastomer, PTFE-Coated Alnico
|
3500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Not Applicable
|
|
Meter
|
Oil
|
0.5 to 5 GPM
|
±2%
|
NPT Female
|
1"
|
Brass, SS, Buna, EPR, FKM, Perfluoroelastomer, PTFE-Coated Alnico
|
3500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Not Applicable
|
Flow Meters for air and water applications. Accuracy: ±3% of full scale Repeatability: ±1% Wetted Parts:316 SS, borosilicate glass, EPR O-Rings Max. Temperature: 200°F
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Water
|
Not Applicable
|
0.074 to 0.74 GPM
|
±3%
|
NPT Female
|
1/2"
|
316 SS, Glass, EPR
|
250 psi
|
93 °C (200 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
Not Applicable
|
0.2 to 2 GPM
|
±3%
|
NPT Female
|
1/2"
|
316 SS, Glass, EPR
|
250 psi
|
93 °C (200 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
Not Applicable
|
0.5 to 5 GPM
|
±3%
|
NPT Female
|
1"
|
316 SS, Glass, EPR
|
200 psi
|
93 °C (200 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
Not Applicable
|
2.6 to 26 GPM
|
±3%
|
NPT Female
|
1"
|
316 SS, Glass, EPR
|
200 psi
|
93 °C (200 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
Not Applicable
|
6.1 to 61 GPM
|
±3%
|
NPT Female
|
2"
|
316 SS, Glass, EPR
|
125 psi
|
93 °C (200 °F)
|
Direct Read
|
No
|
OMEGA's multi-pressure pneumatic flowmeters feature ananodized aluminum body design and easy installation. For air/compressed gas applications at pressures up to 1000 psig.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Air
|
10 to 100 SCFM
|
null
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic
|
1,000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
|
Meter
|
Air
|
15 to 150 SCFM
|
null
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic
|
1,000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
|
Meter
|
Air
|
3 to 25 SCFM
|
null
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic
|
1,000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
|
Meter
|
Air
|
5 to 50 SCFM
|
null
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic
|
1,000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
|
Meter
|
Air
|
15 to 150 SCFM
|
null
|
±2%
|
NPT Female
|
3/4"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic
|
1,000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Made of PTFE, PFA, and PCTFE, the Model FL-10 liquid flow meter is excellent for high-purity flow applications or with corrosive liquids. Available with or without a valve.
Product Number | Category | Media Type | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Water
|
12.5 to 125 mL/min
|
±5%
|
NPT Female
|
1/4"
|
PTFE, PCTFE
|
100 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
25 to 250 mL/min
|
±5%
|
NPT Female
|
1/4"
|
PTFE, PCTFE
|
100 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
40 to 400 mL/min
|
±5%
|
NPT Female
|
1/4"
|
PTFE, PCTFE
|
100 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
50 to 500 mL/min
|
±5%
|
NPT Female
|
1/4"
|
PTFE, PCTFE
|
100 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
100 to 1,000 mL/min
|
±5%
|
NPT Female
|
1/4"
|
PTFE, PCTFE
|
100 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
FLD1000/FLD2000 are designed with unique rotatable scales of dual air-water direct reading graduations showing SCFM and SLPM (air), as well as GPM and LPM (water) markings.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Air, Water
|
0.5 to 5 SCFM
|
0.12 to 1.2 GPM
|
±5%
|
NPT Female
|
3/8"
|
316 SS, Glass, FKM
|
150 psi
|
121 °C (250 °F)
|
Direct Read
|
Yes
|
In-Line
|
|
Meter
|
Air, Water
|
1 to 10 SCFM
|
0.2 to 2 GPM
|
±5%
|
NPT Female
|
3/8"
|
316 SS, Glass, FKM
|
150 psi
|
121 °C (250 °F)
|
Direct Read
|
Yes
|
In-Line
|
|
Meter
|
Air, Water
|
1.5 to 15 SCFM
|
0.3 to 3 GPM
|
±5%
|
NPT Female
|
3/8"
|
316 SS, Glass, FKM
|
150 psi
|
121 °C (250 °F)
|
Direct Read
|
Yes
|
In-Line
|
|
Meter
|
Air, Water
|
2 to 20 SCFM
|
0.4 to 4 GPM
|
±5%
|
NPT Female
|
3/8"
|
316 SS, Glass, FKM
|
150 psi
|
121 °C (250 °F)
|
Direct Read
|
Yes
|
In-Line
|
|
Meter
|
Air, Water
|
3 to 30 SCFM
|
0.5 to 5 GPM
|
±5%
|
NPT Female
|
3/8"
|
316 SS, Glass, FKM
|
150 psi
|
121 °C (250 °F)
|
Direct Read
|
Yes
|
In-Line
|
The Omega FL900 series are heavy duty flowmeter with SS enclosures, unique float stop design allowing internals to be reomoved and replaced without disturbing the tube.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Water
|
Not Applicable
|
0.064 to 0.64 GPM
|
±2%
|
NPT Female
|
1/2"
|
316L SS, Glass, Polycarbonate, EPR
|
300 psi
|
93 °C (200 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
Not Applicable
|
0.226 to 2.26 GPM
|
±2%
|
NPT Female
|
1/2"
|
316L SS, Glass, Polycarbonate, EPR
|
300 psi
|
93 °C (200 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
Not Applicable
|
0.52 to 5.2 GPM
|
±2%
|
NPT Female
|
1"
|
316L SS, Glass, Polycarbonate, EPR
|
250 psi
|
93 °C (200 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
Not Applicable
|
1.26 to 12.6 GPM
|
±2%
|
NPT Female
|
1"
|
316L SS, Glass, Polycarbonate, EPR
|
250 psi
|
93 °C (200 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
Not Applicable
|
3.45 to 34.5 GPM
|
±2%
|
NPT Female
|
1"
|
316L SS, Glass, Polycarbonate, EPR
|
250 psi
|
93 °C (200 °F)
|
Direct Read
|
No
|
The FL1GP-8GP Series are used to blend two or three gases in homogeneous infinitely variable concentrations directly at the end use point.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Air, Water
|
Refer to Product Specs
|
Refer to Product Specs
|
±2%
|
NPT Female
|
1/8"
|
Aluminium, Buna, Glass
|
200 psi
|
121 °C (250 °F)
|
0 to 150
|
Yes
|
Max Air Flow 49 ml/min, 49 ml/min
|
|
Meter
|
Air, Water
|
Refer to Product Specs
|
Refer to Product Specs
|
±2%
|
NPT Female
|
1/8"
|
316 SS, Glass, FKM
|
200 psi
|
121 °C (250 °F)
|
0 to 150
|
Yes
|
Max Air Flow 3,922 ml/min, 3,922ml/min
|
|
Meter
|
Air, Water
|
Refer to Product Specs
|
Refer to Product Specs
|
±2%
|
NPT Female
|
1/8"
|
316 SS, Glass, FKM
|
200 psi
|
121 °C (250 °F)
|
0 to 150
|
Yes
|
Max Air Flow 23,742 ml/min, 23,742 ml/min
|
|
Meter
|
Air, Water
|
Refer to Product Specs
|
Refer to Product Specs
|
±2%
|
NPT Female
|
1/8"
|
316 SS, Glass, FKM
|
200 psi
|
121 °C (250 °F)
|
0 to 150
|
Yes
|
Max Air Flow 444 ml/min, 444 ml/min
|
|
Meter
|
Air, Water
|
Refer to Product Specs
|
Refer to Product Specs
|
±2%
|
NPT Female
|
1/8"
|
316 SS, Glass, FKM
|
200 psi
|
121 °C (250 °F)
|
0 to 150
|
Yes
|
Max Air Flow 93 ml/min, 8,678 ml/min
|
The FL-500WW Series provides flowrate indication for 1 to 5% dilute aqueous chemical solutions used in the treatment of water and wastewater
Product Number | Category | Media Type | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Water
|
0.5 to 5 GPM
|
±5%
|
NPT Female
|
1"
|
PVC, Titanium
|
200 psi
|
65 °C (150 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
1 to 10 GPM
|
±5%
|
NPT Female
|
1"
|
PVC, Titanium
|
200 psi
|
65 °C (150 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
1.5 to 15 GPM
|
±5%
|
NPT Female
|
1"
|
PVC, Titanium
|
200 psi
|
65 °C (150 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
2 to 20 GPM
|
±5%
|
NPT Female
|
1 1/2"
|
PVC, Titanium
|
200 psi
|
65 °C (150 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
3 to 30 GPM
|
±5%
|
NPT Female
|
1 1/2"
|
PVC, Titanium
|
200 psi
|
65 °C (150 °F)
|
Direct Read
|
No
|
Mini-Master® Flowmeter is suitable for both gas and liquid applications with advanced features at a low cost. Compact flowmeter ideal for measuring small volume air.
Product Number | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Air
|
0.1 to 1 SCFH
|
Not Applicable
|
±10%
|
Compression Fittings
|
1/4"
|
Styrene acrylonitrile, SS, black glass, nylon, Polyurethane
|
50 psi
|
None
|
1-1/2"
|
No
|
None
|
|
Air
|
0.2 to 2 SCFH
|
Not Applicable
|
±10%
|
Compression Fittings
|
1/4"
|
Styrene acrylonitrile, SS, black glass, nylon, Polyurethane
|
50 psi
|
None
|
1-1/2"
|
No
|
None
|
|
Air
|
1 to 10 SCFH
|
Not Applicable
|
±10%
|
Compression Fittings
|
1/4"
|
Styrene acrylonitrile, SS, black glass, nylon, Polyurethane
|
50 psi
|
None
|
1-1/2"
|
No
|
None
|
|
Air
|
5 to 50 SCFH
|
Not Applicable
|
±10%
|
Compression Fittings
|
1/4"
|
Styrene acrylonitrile, SS, black glass, nylon, Polyurethane
|
50 psi
|
None
|
1-1/2"
|
No
|
None
|
|
Air
|
10 to 100 SCFH
|
Not Applicable
|
±10%
|
Compression Fittings
|
1/4"
|
Styrene acrylonitrile, SS, black glass, nylon, Polyurethane
|
50 psi
|
None
|
1-1/2"
|
No
|
None
|
This rugged direct-reading flowmeter monitors air flow rates to determine optimum performance, flow regulator settings, or pneumatic system performance.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Air
|
10 to 100 SCFM
|
null
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic
|
1,000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
|
Meter
|
Air
|
15 to 150 SCFM
|
null
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic
|
1,000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
|
Meter
|
Air
|
5 to 50 SCFM
|
null
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic
|
1,000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
|
Meter
|
Air
|
25 to 250 SCFM
|
null
|
±2%
|
NPT Female
|
3/4"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic
|
1,000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
|
Meter
|
Air
|
5 to 50 SCFM
|
null
|
±2%
|
NPT Female
|
3/4"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic
|
1,000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
The FL-W7100 Series uses a basic variable-area flowmeter design: a float and tapered tube. As a result, these meters have longer, linear scales and good pointer stability.
Product Number | Category | Media Type | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Water
|
3.3 to 33 GPH
|
±3%
|
NPT Female
|
1/2"
|
316 SS, FKM
|
1,500 psi
|
199 °C (350 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
0.11 to 1.1 GPM
|
±3%
|
NPT Female
|
1/2"
|
316 SS, FKM
|
1,500 psi
|
199 °C (350 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
0.2 to 2 GPM
|
±3%
|
NPT Female
|
1/2"
|
316 SS, FKM
|
1,500 psi
|
199 °C (350 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
0.4 to 4 GPM
|
±3%
|
NPT Female
|
1/2"
|
316 SS, FKM
|
1,500 psi
|
199 °C (350 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
0.6 to 6 GPM
|
±3%
|
NPT Female
|
1/2"
|
316 SS, FKM
|
1,500 psi
|
199 °C (350 °F)
|
Direct Read
|
No
|
The Mini-Master flowmeters are suitable for both gas and liquid applications with advanced features at a low cost.
Product Number | Media Type | Accuracy | Max Operating Pressure | Max Process Temperature | Process Connection Type | Process Connection Size | Wetted Materials | Gas Flow Range | Liquid Flow Range | Scale | Valve Included | Scale Length |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Compatible gases and liquids
|
±4% FS
|
100 psi (6.9 bar) with compression fitting. 50 psi (3.4 bar) with tubing clamp
|
130°F (54°C)
|
male NPT
|
5/16"
|
Body Nylon 12 O-rings Buna-N (optional materials available) Float Black glass, K monel, stainless steel, tungsten carbide
|
0.2-1.2 SCFH AIR
|
None
|
1-10 SCFH AIR
|
No
|
3" (76.2 mm)
|
|
Compatible gases and liquids
|
±4% FS
|
101 psi (6.9 bar) with compression fitting. 50 psi (3.4 bar) with tubing clamp
|
130°F (54°C)
|
male NPT
|
5/16"
|
Body Nylon 12 O-rings Buna-N (optional materials available) Float Black glass, K monel, stainless steel, tungsten carbide
|
0.5-2.5 SCFH AIR
|
None
|
2-20 SCFH AIR
|
No
|
3" (76.2 mm)
|
|
Compatible gases and liquids
|
±4% FS
|
102 psi (6.9 bar) with compression fitting. 50 psi (3.4 bar) with tubing clamp
|
130°F (54°C)
|
male NPT
|
5/16"
|
Body Nylon 12 O-rings Buna-N (optional materials available) Float Black glass, K monel, stainless steel, tungsten carbide
|
0.5-5 SCFH AIR
|
None
|
5-50 SCFH AIR
|
No
|
3" (76.2 mm)
|
|
Compatible gases and liquids
|
±4% FS
|
103 psi (6.9 bar) with compression fitting. 50 psi (3.4 bar) with tubing clamp
|
130°F (54°C)
|
male NPT
|
5/16"
|
Body Nylon 12 O-rings Buna-N (optional materials available) Float Black glass, K monel, stainless steel, tungsten carbide
|
1-10 SCFH AIR
|
None
|
10-100 SCFH AIR
|
No
|
3" (76.2 mm)
|
|
Compatible gases and liquids
|
±4% FS
|
104 psi (6.9 bar) with compression fitting. 50 psi (3.4 bar) with tubing clamp
|
130°F (54°C)
|
male NPT
|
5/16"
|
Body Nylon 12 O-rings Buna-N (optional materials available) Float Black glass, K monel, stainless steel, tungsten carbide
|
2-20 SCFH AIR
|
None
|
20-200 SCFH AIR
|
No
|
3" (76.2 mm)
|
The FL-500UP is a specialized meter for monitoring the flow rate of ultra-pure water to tools, on deionized water returns, and UPW returns.
Product Number | Category | Media Type | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Water
|
0.5 to 5 GPM
|
±5%
|
NPT Female
|
1"
|
Polysulfone, Perfluoroelastomer, PVDF, 316 SS
|
150 psi
|
65 °C (150 °F)
|
Direct Read
|
No
|
Switch Kits Available
|
|
Meter
|
Water
|
1 to 10 GPM
|
±5%
|
NPT Female
|
1"
|
Polysulfone, Perfluoroelastomer, PVDF, 316 SS
|
150 psi
|
65 °C (150 °F)
|
Direct Read
|
No
|
Switch Kits Available
|
|
Meter
|
Water
|
1.5 to 15 GPM
|
±5%
|
NPT Female
|
1"
|
Polysulfone, Perfluoroelastomer, PVDF, 316 SS
|
150 psi
|
65 °C (150 °F)
|
Direct Read
|
No
|
Switch Kits Available
|
|
Meter
|
Water
|
2 to 20 GPM
|
±5%
|
NPT Female
|
1 1/2"
|
Polysulfone, Perfluoroelastomer, PVDF, 316 SS
|
150 psi
|
65 °C (150 °F)
|
Direct Read
|
No
|
Switch Kits Available
|
|
Meter
|
Water
|
3 to 30 GPM
|
±5%
|
NPT Female
|
1 1/2"
|
Polysulfone, Perfluoroelastomer, PVDF, 316 SS
|
150 psi
|
65 °C (150 °F)
|
Direct Read
|
No
|
Switch Kits Available
|
Product Number | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features | Scale Length |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Air
|
0.1-1 SCFH AIR
|
Not Applicable
|
±5%
|
NPT Female
|
1/8"
|
Acrylic, Buna, Nickle Plated Brass, Black Acetal
|
100 psi (6.9 bar)
|
65°C (150°F)
|
Direct Read
|
No
|
Panel Mount
|
2" (50.8 mm)
|
|
Air
|
0.2-2 SCFH AIR
|
Not Applicable
|
±5%
|
NPT Female
|
1/8"
|
Acrylic, Buna, Nickle Plated Brass, Black Glass
|
100 psi (6.9 bar)
|
65°C (150°F)
|
Direct Read
|
No
|
Panel Mount
|
2" (50.8 mm)
|
|
Air
|
0.6-5 SCFH AIR
|
Not Applicable
|
±5%
|
NPT Female
|
1/8"
|
Acrylic, Buna, Nickle Plated Brass, Black Glass
|
100 psi (6.9 bar)
|
65°C (150°F)
|
Direct Read
|
No
|
Panel Mount
|
2" (50.8 mm)
|
|
Air
|
1-10 SCFH AIR
|
Not Applicable
|
±5%
|
NPT Female
|
1/8"
|
Acrylic, Buna, Nickle Plated Brass, Black Glass
|
100 psi (6.9 bar)
|
65°C (150°F)
|
Direct Read
|
No
|
Panel Mount
|
2" (50.8 mm)
|
|
Air
|
2-20 SCFH AIR
|
Not Applicable
|
±5%
|
NPT Female
|
1/8"
|
Acrylic, Buna, Nickle Plated Brass, Black Glass
|
100 psi (6.9 bar)
|
65°C (150°F)
|
Direct Read
|
No
|
Panel Mount
|
2" (50.8 mm)
|
The FL-8000A Series of general purpose flowmeters is designed to provide economical, accurate flow rate indication for oil and water and can be mounted in any position.
Product Number | Category | Media Type | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Oil
|
3 to 30 GPM
|
±2%
|
NPT Female
|
1 1/4"
|
Aluminum, 302 SS, Polyphenylene sulfide,Ceramic, FKM
|
3500 psi
|
204 °C (400 °F)
|
Direct Read
|
No
|
|
Meter
|
Oil
|
5 to 50 GPM
|
±2%
|
NPT Female
|
1 1/4"
|
Aluminum, 302 SS, Polyphenylene sulfide,Ceramic, FKM
|
3500 psi
|
204 °C (400 °F)
|
Direct Read
|
No
|
|
Meter
|
Oil
|
10 to 75 GPM
|
±2%
|
NPT Female
|
1 1/4"
|
Aluminum, 302 SS, Polyphenylene sulfide,Ceramic, FKM
|
3500 psi
|
204 °C (400 °F)
|
Direct Read
|
No
|
|
Meter
|
Oil
|
10 to 100 GPM
|
±2%
|
NPT Female
|
1 1/4"
|
Aluminum, 302 SS, Polyphenylene sulfide,Ceramic, FKM
|
3500 psi
|
204 °C (400 °F)
|
Direct Read
|
No
|
|
Meter
|
Oil
|
10 to 150 GPM
|
±2%
|
NPT Female
|
1 1/4"
|
Aluminum, 302 SS, Polyphenylene sulfide,Ceramic, FKM
|
3500 psi
|
204 °C (400 °F)
|
Direct Read
|
No
|
In-Line Flow Monitors are ideal for direct measurement for a range of compatible gases, oil, or water based liquids. Applications include pulp and paper and heating loop flow.
Product Number | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Scale | Valve Included |
---|---|---|---|---|---|---|---|---|---|---|
|
Air or Non Corrosive Gases
|
2-22 SCFM
|
non applicable
|
±2%
|
NPT Female
|
1/4"
|
Aluminum, Brass, 303 SS casing
|
3500 psi
|
Direct Read
|
No
|
|
Water
|
Not Applicable
|
0.5 to 5 GPM
|
±2%
|
NPT Female
|
1/2"
|
Aluminum, Brass, 303 SS casing
|
3500 psi
|
Direct Read
|
No
|
|
Water
|
Not Applicable
|
2 to 15 GPM
|
±2%
|
NPT Female
|
3/4"
|
Aluminum, Brass, 303 SS casing
|
3500 psi
|
Direct Read
|
No
|
|
Water
|
Not Applicable
|
2 to 20 GPM
|
±2%
|
NPT Female
|
3/4"
|
Aluminum, Brass, 303 SS casing
|
3500 psi
|
Direct Read
|
No
|
|
Water
|
Not Applicable
|
5 to 35 GPM
|
±2%
|
NPT Female
|
1"
|
Aluminum, Brass, 303 SS casing
|
3500 psi
|
Direct Read
|
No
|