$424.49

Item# CNI3222-AL

Volume discounts available
Volume Discount Schedule
Quantity Price each
1-9 $424.49
10-24 $403.27
25-49 $382.04
50-99 $360.82
100-499 $339.59
500+ $318.37

In Stock

Lead Time (If not in stock): 6 weeks

Product Specs

<< See all Product Models
Brand
A/D Conversion Dual Slope
Accuracy ± 0.5 °C (± 0.9 °F)
Accuracy Detail Accuracy @ 25°C: ± 0.5°C temp nominal; 0.03% rdg ± 0.03% range process and strain
Additional Features 1 Simplified Alarm Menus, Programmable 3 Color Display
Analog Current 0 to 20 mA (500 Ω maximum)
Approvals UL, C-UL, UKCA, CE per EN61010- 1:2001, F
CMRR 120 dB
Cold Junction Compensation 50 ppm/°C
Control Characteristics Control Action: Reverse (heat) or direct (cool) Rate: 0 to 399.9 s Reset: 0 to 3999 s Cycle Time: 1 to 199 s; set to 0 for on/off Gain: 0.5 to 100% of span; setpoints 1 or 2 Damping: 0000 to 0008 Soak: 00.00 to 99.59 (HH:MM), or OFF
Control Mode Alarms
Control Output SSR Relay
Current, Max 0 to 20 mA (5 Ω load)
Cutout Dimensions 22.5 x 45 mm
Data Interface None
Decimal Selection 0,001, 0,01, 0,1, None
Digital Filter Programmable
Display Size 46 mm (1.8 in)
Display Type 4 Digit LED
Display Type Note 4-digit 9-segment LED 10.2 mm (0.40"); i32, i16, i16D, i8DV 21 mm (0.83"); i8 10.2 mm (0.40") and 21 mm (0.83"); i8DH RED, GREEN, and AMBER programmable colors for process variable, setpoint and temperature units
Electrical Connection Screw Terminal
Enclosure Ratings None
Form factor 1/32 DIN
Height 25.4 mm
Impedance Input 10 MΩ for 100 mV; 1 MΩ for 1V or 10 Vdc
Input Configuration Single-ended
Input Type Thermocouple, RTD, mA, Voltage
Input Voltage 0 to 100 mV, 0 to 1 Vdc, 0 to 10 Vdc
Isolated Analog Voltage 0 to 10 Vdc (max 20 mA)
Isolation Isolation Power to Input/Output: 2300 Vac per 1 minute test For Low Voltage Power Option: 1500 Vac per 1 minute test Power to Relay/SSR Output: 2300 Vac per 1 minute test Relay/SSR to Relay/SSR Output: 2300 Vac per 1 minute test RS232/485 to Input/Output: 500 Vac per 1 minute test
Length 127 mm
Linearization Points None
Measurement Type Current, Strain, Voltage
NMRR 60 dB
Number of Control Outputs 2
Number of Inputs 1
Offset Adjustment -1999 to 9999
Output Detail 2 SSR, 0.5A;Control Output 1 and 2 Relay: 250 Vac or 30 Vdc @ 3 A (resistive load); configurable for on/off, PID and ramp and soak Output 1: SPDT, can be configured as alarm 1 output Output 2: SPDT, can be configured as alarm 2 output SSR: 20 to 265 Vac @ 0.05 to 0.5 A (resistive load); continuous DC Pulse: Non-isolated; 10 Vdc @ 20 mA Analog Output (Output 1 Only): Non-isolated, proportional 0 to 10 Vdc or 0 to 20 mA; 500 52 max Output 3 Retransmission Isolated Analog Voltage and Current Current: 10 V max @ 20 mA output Voltage: 20 mA max for 0 to 10 V output
Output Signal None
Polarity Unipolar
RTD Type 100/500/1000Ω Pt sensor; 2-, 3- or 4-wire; α=0.00385 or 0.00392
Ramp Setpoint Ramp to Setpoint: 00.00 to 99.59 (HH:MM), or OFF
Ramp and Soak None
Remote Setpoint None
Resolution 1°/0.1°; 10 µV process
Sampling Rate 3 Hz (3 updates/second)
Set Point Adjustment Menu Configurable
Span Adjustment 0.001 to 9999 counts
Step Response 0.7 sec for 99.9%
Supply Power Note 90 to 240 Vac ± 10%, 50 to 400 Hz*, 110 to 375 Vdc, equivalent voltage; Excitation Voltage Note-24 Vdc @ 25 mA (not available for low-power option)
Supply Power Type AC
Supply Voltage 90 to 240 Vac
Temperature Stability Temperature Stability: RTD: 0.04°C/°C; TC @ 25°C (77°F): 0.05°C/°C ; Cold Junction Compensation Process: 50 ppm/°C
Thermocouple Lead Resistance, Max 100 Ω
Thermocouple Type J, K, T, E, R, S, B, C, N, L (J DIN)
Tuning Autotune
Weight 127 g
Width 48 mm
See All Specs Show Less
i-Series Temperature, Process and Strain Controllers CNI3222-AL CNI3222-AL

Accessories

Microprocessor-based Controller Self container Temperature controller
$1,169.44
0 In Stock
en-US
en
Save Configuration