Sanitary, Rangeable, Pressure Transmitters with Display
-15 to 100 psi, 1.5" Tri-ClampQuantity | Price each |
---|---|
1-4 | $824.92 |
5-9 | $783.67 |
10-24 | $767.18 |
25-49 | $734.18 |
50-99 | $717.68 |
100+ | $701.18 |
Please add to cart to keep it or exit the configuration
- Pressure Transducer for Sanitary or CIP (Clean-in-Place) Applications
- Meets 3-A sanitary standards for food, beverage, dairy, and pharmaceutical applications
- IP67 316 SS enclosure protects against harsh environments
- 5 digit display for easy monitoring
- +/- 0.2% URL accuracy for precise pressure measurements
Edit Options
View all modelsNot all combinations are valid. Options compatible with previous selections will be in bold.
*Highlighted options are not compatible. Please select a different combination.
Product Specs
- Accuracy ±0.2TD% SPAN
- Electrical Connection 4 pin male M12
- Output Signal 4-20mA Two wire
- Storage Temperature -40 to 85°C (-40 to 185°F)
- Ambient Temperature Effects (-20°C to 70°C) ±(0.1+0.1TD) % SPAN
- Damping Time Selectable, 0 to 100 S
- Environmental Rating IP67
- Housing Material 316 SS
- Isolating Diaphragm 316L SS
- Load Resistance <(U-10.5)/0.021
- Long Term Stability +/- 0.1% URL / year
- Media Temperature -40 to 120°C (-40 to 250°F)
- Media Fluids and gasses compatible with 316 SS and FKM
- Mounting Position Effects Apply to any position. Install error less than 0.06 psi can be corrected by PV=0 reset.
- Operating Temperature -10 to 110°C (14 to 230°F)
- Power Consumption 500mW(20.8mA output @ 24VDC)
- Power Supply Effects ± 0.005TD% SPAN/V (Zero and Span)
- Process Connection/Material Tri-Clamp
- Sensor Fill Fluid Dipropylene Glycol (Carrylate/Caprate)
- Sensor Response Time 200 mS
- Sensor Seal O-ring, FKM
- Supply Voltage 10.5 to 55VDC
- Transmission Distance < 1000m
- Vibration Effects GB/T 1827.3/IEC61298-3 tests,20g (5-2000HZ, max<±3mm) <0.1% URL
- Weight 1.14 lbs
Omega’s PX3005K02 is a compact, rangeable, digital sanitary pressure transmitter that is ideal for monitoring pressures in food and pharmaceutical industries where a flush diaphragm design is required. The rugged 316 stainless-steel enclosure is IP67 rated making it suitable for washdown environments. A 5-digit backlit LCD allows for full precision representation of process variable. This hygienic design is certified through 3-A sanitary standards and the best choice for process automation and tank level applications where consistent reliable pressure management are essential.
Range Limits | |||||||||
Nominal Value | Minimum Span | Upper (URL) | Lower (URL) | Over Range Limit | |||||
kPa | PSI | kPa | PSI | kPa | PSI | kPa | PSI | kPa | PSI |
20 | 3 | 10 | 1.5 | 20 | 3 | -20 | -3 | 30 | 4.5 |
35 | 5 | 20 | 3 | 35 | 5 | -35 | -5 | 52.5 | 7.5 |
100 | 15 | 35 | 5 | 100 | 15 | VAC | VAC | 150 | 22 |
200 | 30 | 100 | 15 | 200 | 30 | VAC | VAC | 300 | 45 |
700 | 100 | 200 | 30 | 700 | 100 | VAC | VAC | 1050 | 150 |
MPa | PSI | MPa | PSI | MPa | PSI | MPa | PSI | MPa | PSI |
1 | 150 | 0.5 | 75 | 1 | 150 | VAC | VAC | 1.5 | 220 |
1.7 | 250 | 1 | 150 | 1.7 | 250 | VAC | VAC | 2.55 | 370 |
3.5 | 500 | 1.7 | 250 | 3.5 | 500 | VAC | VAC | 5.25 | 750 |