Call us at 1-888-826-6342
FTB-201 turbine meters have male flared-end fittings for easy connections and features a mating 2-wire connector with optional integrally mounted signal conditioners
Product Number | Category | Media type | Flow Range | Accuracy | Output Signal | Max Operating Pressure | Max Process Temperature | Wetted Materials | Process Connection Type | Process Connection Size | Display |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Liquid
|
0.35 to 3.5 GPM
|
±0.5%
|
Sinusoidal Wave
|
5,000 psi
|
232 °C (450 °F)
|
304 SS, 17-4 SS, 440C SS
|
AN 37° Flare Male
|
1/2"
|
No Display
|
|
Meter
|
Liquid
|
0.75 to 7.5 GPM
|
±0.5%
|
Sinusoidal Wave
|
5,000 psi
|
232 °C (450 °F)
|
304 SS, 17-4 SS, 440C SS
|
AN 37° Flare Male
|
1/2"
|
No Display
|
|
Meter
|
Liquid
|
1.25 to 9.5 GPM
|
±0.5%
|
Sinusoidal Wave
|
5,000 psi
|
232 °C (450 °F)
|
304 SS, 17-4 SS, 440C SS
|
AN 37° Flare Male
|
1/2"
|
No Display
|
|
Meter
|
Liquid
|
1.75 to 16 GPM
|
±0.5%
|
Sinusoidal Wave
|
5,000 psi
|
232 °C (450 °F)
|
304 SS, 17-4 SS, 440C SS
|
AN 37° Flare Male
|
5/8"
|
No Display
|
|
Meter
|
Liquid
|
2.5 to 29 GPM
|
±0.5%
|
Sinusoidal Wave
|
5,000 psi
|
232 °C (450 °F)
|
304 SS, 17-4 SS, 440C SS
|
AN 37° Flare Male
|
3/4"
|
No Display
|
This high accuracy Gas Turbine system measures the volumetric flow of gas through a pipeline. Gas flowing through the meter turns the turbine rotor.
Product Number | Category | Media type | Flow Range | Accuracy | Output Signal | Max Operating Pressure | Max Process Temperature | Wetted Materials | Process Connection Type | Process Connection Size | Display | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter & Signal Conditioner
|
Air or Natural Gas
|
0.13 to 1.6 ACFM
|
±1%
|
Amplified Square Wave, 1 to 5V, 4 to 20 mA
|
6,000 psi
|
149 °C (300 °F)
|
316L SS, 17-4 SS
|
NPT Male
|
1/2"
|
No Display
|
ATEX Approval For Enclosure
|
|
Meter & Signal Conditioner
|
Air or Natural Gas
|
0.35 to 3.5 ACFM
|
±1%
|
Amplified Square Wave, 1 to 5V, 4 to 20 mA
|
6,000 psi
|
149 °C (300 °F)
|
316L SS, 17-4 SS
|
NPT Male
|
1/2"
|
No Display
|
ATEX Approval For Enclosure
|
|
Meter & Signal Conditioner
|
Air or Natural Gas
|
0.27 to 2.3 ACFM
|
±1%
|
Amplified Square Wave, 1 to 5V, 4 to 20 mA
|
6,000 psi
|
149 °C (300 °F)
|
316L SS, 17-4 SS
|
NPT Male
|
1/2"
|
No Display
|
ATEX Approval For Enclosure
|
|
Meter & Signal Conditioner
|
Air or Natural Gas
|
0.6 to 5 ACFM
|
±1%
|
Amplified Square Wave, 1 to 5V, 4 to 20 mA
|
6,000 psi
|
149 °C (300 °F)
|
316L SS, 17-4 SS
|
NPT Male
|
1/2"
|
No Display
|
ATEX Approval For Enclosure
|
|
Meter & Signal Conditioner
|
Air or Natural Gas
|
0.45 to 4.4 ACFM
|
±1%
|
Amplified Square Wave, 1 to 5V, 4 to 20 mA
|
4,400 psi
|
149 °C (300 °F)
|
316L SS, 17-4 SS
|
NPT Male
|
3/4"
|
No Display
|
ATEX Approval For Enclosure
|
The FTB-630 Series turbine meters are dry-register mechanical totalizers that offer accurate, economical reading of high flows with low pressure loss.
Product Number | Category | Media type | Flow Range | Accuracy | Output Signal | Max Operating Pressure | Max Process Temperature | Wetted Materials | Process Connection Type | Process Connection Size | Display |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Liquid
|
16 to 132 GPM
|
±2%
|
Not Applicable
|
200 psi
|
40 °C (105 °F)
|
Cast Iron, ABS, Alnico, Tungstun Steal, Ruby
|
ANSI Flange
|
2"
|
Mechanical Counter
|
|
Meter
|
Liquid
|
24 to 352 GPM
|
±2%
|
Not Applicable
|
200 psi
|
40 °C (105 °F)
|
Cast Iron, ABS, Alnico, Tungstun Steal, Ruby
|
ANSI Flange
|
3"
|
Mechanical Counter
|
|
Meter
|
Liquid
|
40 to 528 GPM
|
±2%
|
Not Applicable
|
200 psi
|
40 °C (105 °F)
|
Cast Iron, ABS, Alnico, Tungstun Steal, Ruby
|
ANSI Flange
|
4"
|
Mechanical Counter
|
|
Meter
|
Liquid
|
80 to 1,320 GPM
|
±2%
|
Not Applicable
|
200 psi
|
40 °C (105 °F)
|
Cast Iron, ABS, Alnico, Tungstun Steal, Ruby
|
ANSI Flange
|
6"
|
Mechanical Counter
|
|
Meter
|
Liquid
|
140 to 2,200 GPM
|
±2%
|
Not Applicable
|
200 psi
|
40 °C (105 °F)
|
Cast Iron, ABS, Alnico, Tungstun Steal, Ruby
|
ANSI Flange
|
8"
|
Mechanical Counter
|
Product Number | Media type | Flow Range | Accuracy | Output Signal | Max Operating Pressure | Max Process Temperature | Wetted Materials | Process Connection Type | Process Connection Size |
---|---|---|---|---|---|---|---|---|---|
|
Liquid
|
0.08 to 0.4 GPM (0.3 to 1.5 LPM)
|
±1%
|
Amplified Square Wave
|
5,000 psi
|
85 °C (185 °F)
|
300 Series SS, Carbide, Nickel
|
NPT Male
|
1/2"
|
|
Liquid
|
0.3 to 3 GPM (1.1 to 11 LPM)
|
±1%
|
Amplified Square Wave
|
5,000 psi
|
85 °C (185 °F)
|
300 Series SS, Carbide, Nickel
|
NPT Male
|
1/2"
|
|
Liquid
|
0.9 to 9 GPM (3.4 to 34 LPM)
|
±1%
|
Amplified Square Wave
|
5,000 psi
|
85 °C (185 °F)
|
300 Series SS, Carbide, Nickel
|
NPT Male
|
1/2"
|
|
Liquid
|
1.6 to 16 GPM (6 to 60 LPM)
|
±1%
|
Amplified Square Wave
|
5,000 psi
|
85 °C (185 °F)
|
300 Series SS, Carbide, Nickel
|
NPT Male
|
1/2"
|
|
Liquid
|
1.6 to 16 GPM (6 to 60 LPM)
|
±1%
|
Amplified Square Wave
|
5,000 psi
|
85 °C (185 °F)
|
300 Series SS, Carbide, Nickel
|
NPT Male
|
1"
|
The FP-5060 Series micro-flow sensors are constructed of polyphenylene sulfide and have high material strength for clean process liquids, regardless of fluid color.
Product Number | Category | Media type | Flow Range | Accuracy | Output Signal | Max Operating Pressure | Max Process Temperature | Wetted Materials | Process Connection Type | Process Connection Size | Display |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Liquid
|
0.11 to 2.6 LPM
|
±1%
|
NPN
|
80 psi
|
80 °C (176 °F)
|
Polypropylene Sulfide, FKM
|
NPT Male
|
1/4"
|
No Display
|
|
Meter
|
Liquid
|
0.11 to 2.6 LPM
|
±1%
|
NPN
|
80 psi
|
80 °C (176 °F)
|
Polypropylene Sulfide, FKM
|
ISO 7/1-R
|
1/4"
|
No Display
|
G-Series Sanitary Turbine Flow Meters are volumetric flow measurement devices. The moving fluid is used to turn a rotor who's speed is proportional to the fluid velocity or flowrate.
Product Number | Media type | Flow Range | Accuracy | Output Signal | Max Process Temperature | Wetted Materials | Process Connection Type | Process Connection Size | Features |
---|---|---|---|---|---|---|---|---|---|
|
Liquid
|
6.7 to 67 GPM (25 to 252 L/min)
|
±0.5%
|
Choose Magnetic Pickup from Accessories
|
107°C (225°F)
|
316 SS, CD4MCu SS, PEEK
|
Tri-Clamp
|
1-1/2"
|
K-Factor 896 PPG (237 PPL)
|
|
Liquid
|
17 to 177 GPM (67 to 670 L/min)
|
±0.5%
|
Choose Magnetic Pickup from Accessories
|
107°C (225°F)
|
316 SS, CD4MCu SS, PEEK
|
Tri-Clamp
|
1-1/2"
|
K-Factor 340 PPG (90 PPL)
|
|
Liquid
|
33 to 330 GPM (125 to 1250 L/min)
|
±0.5%
|
Choose Magnetic Pickup from Accessories
|
107°C (225°F)
|
316 SS, CD4MCu SS, PEEK
|
Tri-Clamp
|
2"
|
K-Factor 181 PPG (48 PPL)
|
FTB790 Series turbine meters with microprocessor-based electronics offers a durable, compact, high-precision fluid measurement device, with total and rate indication.
Product Number | Media type | Flow Range | Accuracy | Output Signal | Max Operating Pressure | Max Process Temperature | Wetted Materials | Process Connection Type | Process Connection Size | Display | Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Liquid
|
1 to 10 GPM (3.8 to 38 L/min
|
±2%
|
Not Applicable
|
1500 psi
|
54 °C (129 °F)
|
316 SS, Ceramic, Tungsten Carbide, PVDF
|
NPT Female
|
1/2"
|
LCD
|
FM Approved
|
|
Liquid
|
2 to 20 GPM (7.6 to 76 L/min)
|
±1.5%
|
Not Applicable
|
1500 psi
|
54 °C (129 °F)
|
316 SS, Ceramic, Tungsten Carbide, PVDF
|
NPT Female
|
3/4"
|
LCD
|
FM Approved
|
|
Liquid
|
5 to 50 GPM (19 to 190 L/min)
|
±1.5%
|
Not Applicable
|
1500 psi
|
54 °C (129 °F)
|
316 SS, Ceramic, Tungsten Carbide, PVDF
|
NPT Female
|
1"
|
LCD
|
FM Approved
|
|
Liquid
|
10 to 100 GPM (38 to 380 L/min)
|
±1%
|
Not Applicable
|
1500 psi
|
54 °C (129 °F)
|
316 SS, Ceramic, Tungsten Carbide, PVDF
|
NPT Female
|
1-1/2"
|
LCD
|
FM Approved
|
|
Liquid
|
20 to 200 GPM (76 to 760 L/min)
|
±1%
|
Not Applicable
|
1500 psi
|
54 °C (129 °F)
|
316 SS, Ceramic, Tungsten Carbide, PVDF
|
NPT Female
|
2"
|
LCD
|
FM Approved
|
The FTB2000 Hall-effect turbine is ideal for applications involving low flow liquid monitoring. The low cost makes it an ideal replacement dispensing timer systems.
Product Number | Category | Media type | Flow Range | Accuracy | Output Signal | Max Operating Pressure | Max Process Temperature | Wetted Materials | Process Connection Type | Process Connection Size | Display | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Liquid
|
0.5 to 5 LPM
|
±3%
|
Amplified Square Wave
|
200 psi
|
100 °C (212 °F)
|
Nylon, PTFE, Graphite
|
NPT Male
|
3/8"
|
No Display
|
Not Applicable
|
|
Meter
|
Liquid
|
0.5 to 7.5 LPM
|
±3%
|
Amplified Square Wave
|
200 psi
|
100 °C (212 °F)
|
Nylon, PTFE, Graphite
|
NPT Male
|
3/8"
|
No Display
|
Not Applicable
|