Call us at 1-888-826-6342
The FLK2000 Series has a maximum temperature rating of 140°F (60°C) and a maximum pressure rating of 125 psi and are the ideal choice for medical and laboratory applications.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Air
|
5 to 50 LPM
|
Not Applicable
|
±4%
|
NPT Female
|
1/8"
|
Acrylic, Brass, SS, Silicone rubber
|
125 psi
|
60°C (140°F)
|
Direct Read
|
No
|
|
Meter
|
Air
|
0.2 to 2 SCFH
|
Not Applicable
|
±4%
|
NPT Female
|
1/8"
|
Acrylic, Brass, SS, Silicone rubber
|
125 psi
|
60°C (140°F)
|
Direct Read
|
Yes
|
|
Meter
|
Air
|
0.2 to 3 SCFH
|
Not Applicable
|
±4%
|
NPT Female
|
1/8"
|
Acrylic, Brass, SS, Silicone rubber
|
125 psi
|
60°C (140°F)
|
Direct Read
|
Yes
|
|
Meter
|
Air
|
0.85 to 8.5 SCFH
|
Not Applicable
|
±4%
|
NPT Female
|
1/8"
|
Acrylic, Brass, SS, Silicone rubber
|
125 psi
|
60°C (140°F)
|
Direct Read
|
Yes
|
|
Meter
|
Air
|
2.5 to 25 SCFH
|
Not Applicable
|
±4%
|
NPT Female
|
1/8"
|
Acrylic, Brass, SS, Silicone rubber
|
125 psi
|
60°C (140°F)
|
Direct Read
|
Yes
|
The FLD is suitable for metering carrier gases in chromatography, indicating and controlling gases in manufacturing processes, and liquid and gas measurement in laboratories.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Air
|
7.5 to 75 mL/Min
|
Not Applicable
|
±5%
|
NPT Female
|
1/8"
|
Aluminium, Glass, Buna, Carboloy
|
200 psi
|
121 °C (250 °F)
|
Direct Read
|
Yes
|
Panel Mount, 150 mm
|
|
Meter
|
Air
|
0.22 to 2.2 SCFH
|
Not Applicable
|
±5%
|
NPT Female
|
1/8"
|
Aluminium, Glass, Buna, Carboloy
|
200 psi
|
121 °C (250 °F)
|
Direct Read
|
Yes
|
Panel Mount, 65 mm
|
|
Meter
|
Air
|
0.6 to 6 SCFH
|
Not Applicable
|
±5%
|
NPT Female
|
1/8"
|
Aluminium, Glass, Buna
|
200 psi
|
121 °C (250 °F)
|
Direct Read
|
Yes
|
Panel Mount, 65 mm
|
|
Meter
|
Air
|
15 to 150 SCFH
|
Not Applicable
|
±5%
|
NPT Female
|
1/8"
|
Aluminium, Glass, Buna, Carboloy
|
200 psi
|
121 °C (250 °F)
|
Direct Read
|
Yes
|
Panel Mount, 65 mm
|
|
Meter
|
Air
|
0.06 to 0.6 SCFM
|
Not Applicable
|
±5%
|
NPT Female
|
1/8"
|
Aluminium, Glass, Buna, Carboloy
|
200 psi
|
121 °C (250 °F)
|
Direct Read
|
Yes
|
Panel Mount, 65 mm
|
The FL-2000 Series offers a wide variety of precision flow meters for use in medical, industrial, chemical, and laboratory applications at an economical price.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Air
|
0.04 to 0.5 LPM
|
Not Applicable
|
±5%
|
NPT Female
|
1/8"
|
Acrylic, Buna, Brass
|
100 psi
|
65 °C (150 °F)
|
Direct Read
|
Yes
|
Panel Mount
|
|
Meter
|
Air
|
0.1 to 1 SCFH
|
Not Applicable
|
±5%
|
NPT Female
|
1/8"
|
Acrylic, Buna, Brass
|
100 psi
|
65 °C (150 °F)
|
Direct Read
|
Yes
|
Panel Mount
|
|
Meter
|
Air
|
0.2 to 2 SCFH
|
Not Applicable
|
±5%
|
NPT Female
|
1/8"
|
Acrylic, Buna, Brass
|
100 psi
|
65 °C (150 °F)
|
Direct Read
|
Yes
|
Panel Mount
|
|
Meter
|
Air
|
0.4 to 5 SCFH
|
Not Applicable
|
±5%
|
NPT Female
|
1/8"
|
Acrylic, Buna, Brass
|
100 psi
|
65 °C (150 °F)
|
Direct Read
|
Yes
|
Panel Mount
|
|
Meter
|
Air
|
1 to 10 SCFH
|
Not Applicable
|
±5%
|
NPT Female
|
1/8"
|
Acrylic, Buna, Brass
|
100 psi
|
65 °C (150 °F)
|
Direct Read
|
Yes
|
Panel Mount
|
FL7000 flow meters are precisely machined from solid acrylic blocks. They are available in 50, 75, 100, 127, and 250 mm scale lengths with accuracies between 2 and 6%.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Water
|
Not Applicable
|
0.1 to 1 GPM
|
±6%
|
NPT Female
|
1/2"
|
316 SS, Acrylic, EPR
|
125 psi
|
54 °C (130 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
Not Applicable
|
0.7 to 7 GPH
|
±6%
|
NPT Female
|
1/4"
|
316 SS, Acrylic, Brass, EPR
|
125 psi
|
54 °C (130 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
Not Applicable
|
1.2 to 12 GPH
|
±6%
|
NPT Female
|
1/4"
|
316 SS, Acrylic, Brass, EPR
|
125 psi
|
54 °C (130 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
Not Applicable
|
2 to 20 GPH
|
±6%
|
NPT Female
|
1/4"
|
316 SS, Acrylic, Brass, EPR
|
125 psi
|
54 °C (130 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
Not Applicable
|
5 to 50 GPH
|
±6%
|
NPT Female
|
1/4"
|
316 SS, Acrylic, Brass, EPR
|
125 psi
|
54 °C (130 °F)
|
Direct Read
|
No
|
The FL-3000 and FL-3100 flowmeters are designed for applications which involve corrosive or ultra-pure fluids. The meters are equipped with built-in PTFE needle valves.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Air, Water
|
1188.7 to 11,887 SCCM
|
31.5 to 315 SCCM
|
±2%
|
NPT Female
|
1/8"
|
PTFE, KEL-F, Glass, Sapphire, Perflurorodastomer
|
100 psi
|
65 °C (150 °F)
|
0 to 150
|
Yes
|
Panel Mount
|
|
Meter
|
Air, Water
|
0.83 to 8.3 SCCM
|
0.0251 to 0.251 SCCM
|
±5%
|
NPT Female
|
1/8"
|
PTFE, KEL-F, Glass, Sapphire, Perflurorodastomer
|
100 psi
|
65 °C (150 °F)
|
0 to 65
|
Yes
|
Panel Mount
|
|
Meter
|
Air, Water
|
29.9 to 299 SCCM
|
0.47 to 4.7 SCCM
|
±2%
|
NPT Female
|
1/8"
|
PTFE, KEL-F, Glass, Sapphire, Perflurorodastomer
|
100 psi
|
65 °C (150 °F)
|
0 to 150
|
Yes
|
Panel Mount
|
|
Meter
|
Air, Water
|
15.9 to 159 SCCM
|
0.3 to 3 SCCM
|
±2%
|
NPT Female
|
1/8"
|
PTFE, KEL-F, Glass, Sapphire, Perflurorodastomer
|
100 psi
|
65 °C (150 °F)
|
0 to 65
|
Yes
|
Panel Mount
|
|
Meter
|
Air, Water
|
7.23 to 72.3 SCCM
|
0.098 to 0.98 SCCM
|
±2%
|
NPT Female
|
1/8"
|
PTFE, KEL-F, Glass, Sapphire, Perflurorodastomer
|
100 psi
|
65 °C (150 °F)
|
0 to 65
|
Yes
|
Panel Mount
|
OMEGA's multi-pressure pneumatic flowmeters feature ananodized aluminum body design and easy installation. For air/compressed gas applications at pressures up to 1000 psig.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Air
|
60 to 600 SCFM
|
null
|
±2%
|
NPT Female
|
1 1/4"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic
|
1,000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
|
Meter
|
Air
|
10 to 100 SCFM
|
null
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic
|
1,000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
|
Meter
|
Air
|
15 to 150 SCFM
|
null
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic
|
1,000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
|
Meter
|
Air
|
3 to 25 SCFM
|
null
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic
|
1,000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
|
Meter
|
Air
|
5 to 50 SCFM
|
null
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic
|
1,000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
FL4000 OEM-style acrylic flow meters are machined from solid acrylic blocks for superb durability. The rear ports extend through the panel for easy hookup.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Water
|
Not Applicable
|
6 to 60 GPH
|
±6%
|
NPT Female
|
1/4"
|
316 SS, Acrylic, Brass, EPR
|
125 psi
|
54 °C (130 °F)
|
Direct Read
|
No
|
Panel Mount
|
|
Meter
|
Water
|
Not Applicable
|
0.7 to 7 GPH
|
±6%
|
NPT Female
|
1/4"
|
316 SS, Acrylic, Brass, EPR
|
125 psi
|
54 °C (130 °F)
|
Direct Read
|
No
|
Panel Mount
|
|
Meter
|
Water
|
Not Applicable
|
1.2 to 12 GPH
|
±6%
|
NPT Female
|
1/4"
|
316 SS, Acrylic, Brass, EPR
|
125 psi
|
54 °C (130 °F)
|
Direct Read
|
No
|
Panel Mount
|
|
Meter
|
Water
|
Not Applicable
|
2.2 to 22 GPH
|
±6%
|
NPT Female
|
1/4"
|
316 SS, Acrylic, Brass, EPR
|
125 psi
|
54 °C (130 °F)
|
Direct Read
|
No
|
Panel Mount
|
|
Meter
|
Water
|
Not Applicable
|
4.4 to 44 GPH
|
±6%
|
NPT Female
|
1/4"
|
316 SS, Acrylic, Brass, EPR
|
125 psi
|
54 °C (130 °F)
|
Direct Read
|
No
|
Panel Mount
|
OMEGA's FL2AA Series multi-tube flow meters are convenient for applications where up to four streams of liquids or gases are to be metered in individual channels.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Air, Water
|
Refer to Product Specs
|
Refer to Product Specs
|
±2%
|
NPT Female
|
1/8"
|
Aluminium, Buna, Glass
|
200 psi
|
121 °C (250 °F)
|
0 to 150
|
Yes
|
Max Air flow 45,227 ml/min, 6,621 ml/min
|
|
Meter
|
Air, Water
|
Refer to Product Specs
|
Refer to Product Specs
|
±2%
|
NPT Female
|
1/8"
|
Aluminium, Buna, Glass
|
200 psi
|
121 °C (250 °F)
|
0 to 150
|
Yes
|
Max Air flow 374 ml/min, 374 ml/min, 374 ml/min
|
|
Meter
|
Air, Water
|
Refer to Product Specs
|
Refer to Product Specs
|
±2%
|
NPT Female
|
1/8"
|
Aluminium, Buna, Glass
|
200 psi
|
121 °C (250 °F)
|
0 to 150
|
Yes
|
Max Air flow 2,423 ml/min, 2,423 ml/min, 2,423 ml/min
|
|
Meter
|
Air, Water
|
Refer to Product Specs
|
Refer to Product Specs
|
±2%
|
NPT Female
|
1/8"
|
316 SS, Glass, FKM
|
200 psi
|
121 °C (250 °F)
|
0 to 150
|
Yes
|
Max Air flow 110 ml/min, 374 ml/min, 1,093 ml/min
|
|
Meter
|
Air, Water
|
Refer to Product Specs
|
Refer to Product Specs
|
±2%
|
NPT Female
|
1/8"
|
Aluminium, Buna, Glass
|
200 psi
|
121 °C (250 °F)
|
0 to 150
|
Yes
|
Max Air flow 2,423 ml/min, 1,682 ml/min, 814 ml/min
|
The FL-500 Series in-line flow meters feature rugged construction, easy installation and direct reading flow rates for water and air at atmospheric and 90 psi pressures.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Air, Water
|
5 to 50 SCFM
|
0.5 to 5 GPM
|
±5%
|
NPT Female
|
1"
|
316 SS, PVC, FKM
|
100 psi
|
65 °C (150 °F)
|
Direct Read
|
No
|
Water Maximum Pressure 200 psi
|
|
Meter
|
Air, Water
|
15 to 90 SCFM
|
1 to 10 GPM
|
±5%
|
NPT Female
|
1"
|
316 SS, PVC, FKM
|
100 psi
|
65 °C (150 °F)
|
Direct Read
|
No
|
Water Maximum Pressure 200 psi
|
|
Meter
|
Air, Water
|
15 to 135 SCFM
|
1.5 to 15 GPM
|
±5%
|
NPT Female
|
1"
|
316 SS, PVC, FKM
|
100 psi
|
65 °C (150 °F)
|
Direct Read
|
No
|
Water Maximum Pressure 200 psi
|
|
Meter
|
Air, Water
|
30 to 300 SCFM
|
3 to 30 GPM
|
±5%
|
NPT Female
|
1 1/2"
|
316 SS, PVC, FKM
|
100 psi
|
65 °C (150 °F)
|
Direct Read
|
No
|
Water Maximum Pressure 200 psi
|
|
Meter
|
Air, Water
|
40 to 400 SCFM
|
4 to 40 GPM
|
±5%
|
NPT Female
|
1 1/2"
|
316 SS, PVC, FKM
|
100 psi
|
65 °C (150 °F)
|
Direct Read
|
No
|
Water Maximum Pressure 200 psi
|
The FLMG flow meters feature rugged construction and direct-reading flow rates of air. The units are calibrated at 100 psi pressure, idea for most compressed air applications.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Air
|
3 to 12 SCFM
|
null
|
±4%
|
NPT Female
|
1/4"
|
Aluminum, Buna, PTFE, SS
|
600 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Not Applicable
|
|
Meter
|
Air
|
6 to 50 SCFM
|
null
|
±4%
|
NPT Female
|
1"
|
Aluminum, Buna, PTFE, SS
|
600 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Not Applicable
|
|
Meter
|
Air
|
6 to 50 SCFM
|
null
|
±4%
|
NPT Female
|
1"
|
Brass, Buna, PTFE, SS
|
600 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Not Applicable
|
|
Meter
|
Air
|
6 to 50 SCFM
|
null
|
±4%
|
NPT Female
|
1"
|
304 SS, FKM, PTFE
|
1,000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Not Applicable
|
|
Meter
|
Air
|
10 to 100 SCFM
|
null
|
±4%
|
NPT Female
|
1"
|
Aluminum, Buna, PTFE, SS
|
600 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Not Applicable
|
The FLC Series is the economical way to monitor municipal water flows, verify pump outlets and monitor fluid conditions. Piston design allows for installation in any position
Product Number | Category | Media Type | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Water
|
3 to 30 GPM
|
±5%
|
NPT Female
|
1"
|
Brass, Polycarbonate, SS, Polysulfone, Buna
|
325 psi
|
93 °C (200 °F)
|
Direct Read
|
No
|
|
Meter
|
Hydraulic Oil
|
0.5 to 5 GPM
|
±5%
|
NPT Female
|
1/2"
|
Polysulfone, SS, Buna
|
325 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
|
Meter
|
Hydraulic Oil
|
1 to 10 GPM
|
±5%
|
NPT Female
|
1/2"
|
Polysulfone, SS, Buna
|
325 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
|
Meter
|
Hydraulic Oil
|
1 to 10 GPM
|
±5%
|
NPT Female
|
3/4"
|
Polysulfone, SS, Buna
|
325 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
|
Meter
|
Hydraulic Oil
|
1.5 to 15 GPM
|
±5%
|
NPT Female
|
3/4"
|
Polysulfone, SS, Buna
|
325 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
The FL-8000A Series of general purpose flowmeters is designed to provide economical, accurate flow rate indication for oil and water and can be mounted in any position.
Product Number | Category | Media Type | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Water
|
10 to 100 GPM
|
±2%
|
NPT Female
|
1 1/4"
|
Brass, 302 SS, Polyphenylene Sulfide, Ceramic, FKM
|
3,500 psi
|
204 °C (400 °F)
|
Direct Read
|
No
|
|
Meter
|
Oil
|
3 to 30 GPM
|
±2%
|
NPT Female
|
1 1/4"
|
Aluminum, 302 SS, Polyphenylene sulfide,Ceramic, FKM
|
3,500 psi
|
204 °C (400 °F)
|
Direct Read
|
No
|
|
Meter
|
Oil
|
5 to 50 GPM
|
±2%
|
NPT Female
|
1 1/4"
|
Aluminum, 302 SS, Polyphenylene sulfide,Ceramic, FKM
|
3,500 psi
|
204 °C (400 °F)
|
Direct Read
|
No
|
|
Meter
|
Oil
|
10 to 75 GPM
|
±2%
|
NPT Female
|
1 1/4"
|
Aluminum, 302 SS, Polyphenylene sulfide,Ceramic, FKM
|
3,500 psi
|
204 °C (400 °F)
|
Direct Read
|
No
|
|
Meter
|
Oil
|
10 to 100 GPM
|
±2%
|
NPT Female
|
1 1/4"
|
Aluminum, 302 SS, Polyphenylene sulfide,Ceramic, FKM
|
3,500 psi
|
204 °C (400 °F)
|
Direct Read
|
No
|
The FL1GP-8GP Series are used to blend two or three gases in homogeneous infinitely variable concentrations directly at the end use point.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Air, Water
|
Refer to Product Specs
|
Refer to Product Specs
|
±2%
|
NPT Female
|
1/8"
|
Aluminium, Buna, Glass
|
200 psi
|
121 °C (250 °F)
|
0 to 150
|
Yes
|
Max Air Flow 23,752 ml/min, 19 ml/min
|
|
Meter
|
Air, Water
|
Refer to Product Specs
|
Refer to Product Specs
|
±2%
|
NPT Female
|
1/8"
|
Aluminium, Buna, Glass
|
200 psi
|
121 °C (250 °F)
|
0 to 150
|
Yes
|
Max Air flow 374 ml/min, 110 ml/min
|
|
Meter
|
Air, Water
|
Refer to Product Specs
|
Refer to Product Specs
|
±2%
|
NPT Female
|
1/8"
|
Aluminium, Buna, Glass
|
200 psi
|
121 °C (250 °F)
|
0 to 150
|
Yes
|
Max Air flow 19 ml/min, 19 ml/min
|
|
Meter
|
Air, Water
|
Refer to Product Specs
|
Refer to Product Specs
|
±2%
|
NPT Female
|
1/8"
|
Aluminium, Buna, Glass
|
200 psi
|
121 °C (250 °F)
|
0 to 150
|
Yes
|
Max Air Flow 49 ml/min, 49 ml/min
|
|
Meter
|
Air, Water
|
Refer to Product Specs
|
Refer to Product Specs
|
±2%
|
NPT Female
|
1/8"
|
Aluminium, Buna, Glass
|
200 psi
|
121 °C (250 °F)
|
0 to 150
|
Yes
|
Max Air Flow 19 ml/min, 2,313 ml/min
|
OMEGA's in-line flowmeters offer high accuracy flow rate indication for oil, water or air and the ability to either control the flowrate or alarm on high or low flowrates.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Air
|
25 to 250 SCFM
|
Not Applicable
|
±2%
|
NPT Female
|
3/4"
|
Aluminum, T302 SS, Ceramic
|
1,000 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
1 Limit Switch
|
|
Meter
|
Oil
|
Not Applicable
|
0.1 to 1 GPM
|
±2%
|
NPT Female
|
1/2"
|
Aluminum, T302 SS, Ceramic
|
3,500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
1 Limit Switch
|
|
Meter
|
Oil
|
Not Applicable
|
0.2 to 2 GPM
|
±2%
|
NPT Female
|
1/2"
|
Aluminum, T302 SS, Ceramic
|
3,500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
1 Limit Switch
|
|
Meter
|
Water
|
Not Applicable
|
0.5 to 5 GPM
|
±2%
|
NPT Female
|
1/2"
|
Brass, T302 SS, Ceramic
|
3,500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
1 Limit Switch
|
|
Meter
|
Water
|
Not Applicable
|
1 to 15 GPM
|
±2%
|
NPT Female
|
1/2"
|
Brass, T302 SS, Ceramic
|
3,500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
1 Limit Switch
|
The FL-6000A Series of general purpose flowmeters is designed to provide economical, accurate flow rate indication for oil and water and can be mounted in any position.
Product Number | Category | Media Type | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Oil
|
0.2 to 2 GPM
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic, FKM
|
3,500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Dual Scale GPM/LPM
|
|
Meter
|
Oil
|
0.5 to 5 GPM
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic, FKM
|
3,500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Dual Scale GPM/LPM
|
|
Meter
|
Oil
|
1 to 10 GPM
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic, FKM
|
3,500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Dual Scale GPM/LPM
|
|
Meter
|
Oil
|
1.5 to 15 GPM
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Aluminum, Polyphenylene Sulfide, Ceramic, FKM
|
3,500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Dual Scale GPM/LPM
|
|
Meter
|
Water
|
0.2 to 2 GPM
|
±2%
|
NPT Female
|
1/2"
|
302 SS, Brass, Polyphenylene Sulfide, Ceramic, FKM
|
3,500 psi
|
116 °C (240 °F)
|
Direct Read
|
No
|
Dual Scale GPM/LPM
|
FLD1000/FLD2000 are designed with unique rotatable scales of dual air-water direct reading graduations showing SCFM and SLPM (air), as well as GPM and LPM (water) markings.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Air, Water
|
1 to 10 SCFM
|
0.2 to 2 GPM
|
±5%
|
NPT Female
|
3/8"
|
316 SS, Glass, FKM
|
150 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
Panel Mount
|
|
Meter
|
Air, Water
|
0.5 to 5 SCFM
|
0.12 to 1.2 GPM
|
±5%
|
NPT Female
|
3/8"
|
316 SS, Glass, FKM
|
150 psi
|
121 °C (250 °F)
|
Direct Read
|
Yes
|
In-Line
|
|
Meter
|
Air, Water
|
1 to 10 SCFM
|
0.2 to 2 GPM
|
±5%
|
NPT Female
|
3/8"
|
316 SS, Glass, FKM
|
150 psi
|
121 °C (250 °F)
|
Direct Read
|
Yes
|
In-Line
|
|
Meter
|
Air, Water
|
1.5 to 15 SCFM
|
0.3 to 3 GPM
|
±5%
|
NPT Female
|
3/8"
|
316 SS, Glass, FKM
|
150 psi
|
121 °C (250 °F)
|
Direct Read
|
Yes
|
In-Line
|
|
Meter
|
Air, Water
|
2 to 20 SCFM
|
0.4 to 4 GPM
|
±5%
|
NPT Female
|
3/8"
|
316 SS, Glass, FKM
|
150 psi
|
121 °C (250 °F)
|
Direct Read
|
Yes
|
In-Line
|
The OMEGA's FL-9000 EZ-View flowmeters provide accurate, in-line indication of oil or water flow rates at an economical cost and can be mounted with no straight pipe runs
Product Number | Category | Media Type | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Water
|
0.5 to 4 GPM
|
±5%
|
NPT Female
|
1"
|
T300 SS, Polysulfone
|
325 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
1 to 7 GPM
|
±5%
|
NPT Female
|
1"
|
T300 SS, Polysulfone
|
325 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
1 to 10 GPM
|
±5%
|
NPT Female
|
1"
|
T300 SS, Polysulfone
|
325 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
1 to 16 GPM
|
±5%
|
NPT Female
|
1"
|
T300 SS, Polysulfone
|
325 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
|
Meter
|
Water
|
3 to 18 GPM
|
±5%
|
NPT Female
|
1"
|
T300 SS, Polysulfone
|
325 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
The FL-9000 Series flowmeter are rugged, low-cost direct reading industrial class flowmeters that are simple to install. They can be mounted in any position
Product Number | Category | Media Type | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Water
|
10 to 100 GPM
|
±5%
|
NPT Female
|
2"
|
Polysulfone, T300 SS, Buna, Brass
|
325 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
Limit Switch Sold Separately
|
|
Meter
|
Oil
|
2 to 25 GPM
|
±5%
|
NPT Female
|
1 1/2"
|
Polysulfone, T300 SS, Buna, Brass
|
325 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
Limit Switch Sold Separately
|
|
Meter
|
Oil
|
5 to 50 GPM
|
±5%
|
NPT Female
|
1 1/2"
|
Polysulfone, T300 SS, Buna, Brass
|
325 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
Limit Switch Sold Separately
|
|
Meter
|
Oil
|
7 to 75 GPM
|
±5%
|
NPT Female
|
1 1/2"
|
Polysulfone, T300 SS, Buna, Brass
|
325 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
Limit Switch Sold Separately
|
|
Meter
|
Oil
|
10 to 100 GPM
|
±5%
|
NPT Female
|
1 1/2"
|
Polysulfone, T300 SS, Buna, Brass
|
325 psi
|
121 °C (250 °F)
|
Direct Read
|
No
|
Limit Switch Sold Separately
|
The OMEGA's precision variable-area flow meters for air, water, and gases have up to ±2% of full scale accuracy. (Models ending in "07" or "45" have ±5% FS accuracy).
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Air, Water
|
37.4 to 374 SCCM
|
0.55 to 5.5 SCCM
|
±2%
|
NPT Female
|
1/8"
|
Aluminum, Glass, Polyacetal
|
200 psi
|
121 °C (250 °F)
|
0 to 150
|
Yes
|
8 Turn Resolution Valve
|
|
Meter
|
Air, Water
|
3.299 to 32.99 SCCM
|
0.062 to 0.62 SCCM
|
±5%
|
NPT Female
|
1/8"
|
Aluminum, Glass, Polyacetal, Carboloy
|
200 psi
|
121 °C (250 °F)
|
0 to 65
|
Yes
|
8 Turn Resolution Valve
|
|
Meter
|
Air, Water
|
0.577 to 5.77 SCCM
|
0.007 to 0.07 SCCM
|
±5%
|
NPT Female
|
1/8"
|
Aluminum, Glass, Polyacetal
|
200 psi
|
121 °C (250 °F)
|
0 to 65
|
Yes
|
8 Turn Resolution Valve
|
|
Meter
|
Air, Water
|
2.008 to 20.08 SCCM
|
81.8 to 818 SCCM
|
±2%
|
NPT Female
|
1/8"
|
Aluminum, Glass, Polyacetal, Carboloy
|
200 psi
|
121 °C (250 °F)
|
0 to 65
|
Yes
|
8 Turn Resolution Valve
|
|
Meter
|
Air, Water
|
20.2 to 202 SCCM
|
0.264 to 2.64 SCCM
|
±2%
|
NPT Female
|
1/8"
|
Aluminum, Glass, Polyacetal
|
200 psi
|
121 °C (250 °F)
|
0 to 65
|
Yes
|
8 Turn Resolution Valve
|
Rugged In-Line Flow Sensors Available in 1/2", 3/4", and 1-1/4" sizes are protected in a sturdy cast aluminum enclosure, and are easy to install and mount in any position.
Product Number | Category | Media Type | Gas Flow Range | Liquid Flow Range | Accuracy | Process Connection Type | Process Connection Size | Wetted Materials | Max Operating Pressure | Max Process Temperature | Scale | Valve Included |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
Water
|
Not Applicable
|
0.5 to 5 GPM
|
±2%
|
NPT Female
|
1/2"
|
Aluminum, T302 SS, Carbon Steel, Silicone, PPS, Ceramic, FKM
|
3,500 psi
|
116 °C (240 °F)
|
Digital
|
No
|
|
Meter
|
Oil
|
Not Applicable
|
0.2 to 2 GPM
|
±2%
|
NPT Female
|
1/2"
|
Brass, T302 SS, Carbon Steel, Silicone, PPS, Ceramic, FKM
|
3,500 psi
|
116 °C (240 °F)
|
Digital
|
No
|
|
Meter
|
Oil
|
Not Applicable
|
0.5 to 5 GPM
|
±2%
|
NPT Female
|
1/2"
|
Brass, T302 SS, Carbon Steel, Silicone, PPS, Ceramic, FKM
|
3,500 psi
|
116 °C (240 °F)
|
Digital
|
No
|
|
Meter
|
Oil
|
Not Applicable
|
1 to 15 GPM
|
±2%
|
NPT Female
|
1/2"
|
Brass, T302 SS, Carbon Steel, Silicone, PPS, Ceramic, FKM
|
3,500 psi
|
116 °C (240 °F)
|
Digital
|
No
|
|
Meter
|
Water
|
Not Applicable
|
0.2 to 2 GPM
|
±2%
|
NPT Female
|
1/2"
|
Aluminum, T302 SS, Carbon Steel, Silicone, PPS, Ceramic, FKM
|
3,500 psi
|
116 °C (240 °F)
|
Digital
|
No
|