Call us at 1-888-826-6342
Battery powered with ABS/Polycarbonate enclosure, two SPDT relays optional and programmable functions. Includes a fixed or spring loaded probe.
Product Number | Category | Input Type | Minimum Temperature Measurement | Maximum Temperature Measurement | Input Connection Type | Display Type | Accuracy Value | Resolution | Supply Power |
---|---|---|---|---|---|---|---|---|---|
|
Digital Thermometers
|
100 Ω RTD
|
-50°C (-58°F)
|
200°C (392°F)
|
1/2" NPT Male Thread
|
Digital
|
Class B per IEC60751
|
0.1
|
2 AA Batteries
|
|
Digital Thermometers
|
100 Ω RTD
|
-50°C (-58°F)
|
200°C (392°F)
|
1/2" NPT Male Thread
|
Digital
|
Class B per IEC60751
|
0.1
|
2 AA Batteries
|
|
Digital Thermometers
|
100 Ω RTD
|
-50°C (-58°F)
|
200°C (392°F)
|
1/2" NPT Male Thread
|
Digital
|
Class B per IEC60751
|
0.1
|
8 to 24 VAC or 9 to 32 VDC
|
|
Digital Thermometers
|
100 Ω RTD
|
-50°C (-58°F)
|
200°C (392°F)
|
1/2" NPT Male Thread
|
Digital
|
Class B per IEC60751
|
0.1
|
8 to 24 VAC or 9 to 32 VDC
|
|
Digital Thermometers
|
100 Ω RTD
|
-50°C (-58°F)
|
200°C (392°F)
|
1/2" NPT Male Thread
|
Digital
|
Class B per IEC60751
|
0.1
|
2 AA Batteries
|
Loop powered 4-20 milliamp output transmitter with ABS/Polycarbonate enclosure and two on-display alarms. Includes fixed or spring loaded RTD probe.
Product Number | Category | Input Type | Minimum Temperature Measurement | Maximum Temperature Measurement | Input Connection Type | Display Type | Accuracy Value | Resolution | Supply Power | |
---|---|---|---|---|---|---|---|---|---|---|
|
Digital Thermometers
|
100 Ω RTD
|
-50°C (-58°F)
|
200°C (392°F)
|
1/2" NPT Male Thread
|
Digital
|
Class B per IEC60751
|
0.1
|
8 to 32 Vdc
|
|
|
Digital Thermometers
|
100 Ω RTD
|
-50°C (-58°F)
|
200°C (392°F)
|
1/2" NPT Male Thread
|
Digital
|
Class B per IEC60751
|
0.1
|
8 to 32 Vdc
|
|
|
Digital Thermometers
|
100 Ω RTD
|
-50°C (-58°F)
|
200°C (392°F)
|
1/2" NPT Male Thread
|
Digital
|
Class B per IEC60751
|
0.1
|
8 to 32 Vdc
|
|
|
Digital Thermometers
|
100 Ω RTD
|
-50°C (-58°F)
|
200°C (392°F)
|
1/2" NPT Male Thread
|
Digital
|
Class B per IEC60751
|
0.1
|
8 to 32 Vdc
|
|
|
Not Applicable
|
Not Applicable
|
Not Applicable
|
Not Applicable
|
Not Applicable
|
Not Applicable
|
1 NPT
|
Not Applicable
|
Not Applicable
|
70 in Long Thermowell
|
Wall mount this high accuracy thermistor thermometer in wetted environments. 0.1 resolution and easy to read LCD screen make this thermometer an essential tool.
Product Number | Minimum Temperature Measurement | Maximum Temperature Measurement | Connection Type | Accuracy Value | Resolution | Battery Type | Measurement Type | Probe Size Cable Length | Weight |
---|---|---|---|---|---|---|---|---|---|
|
0°C (32°F)
|
50°C (122°F)
|
Locking Mini Phone Plug
|
±1°C (±1.6°F)
|
0.1°C (0.1°F)
|
Alkaline
|
Temperature
|
1500 mm (59 in)
|
200 g (7.1 oz)
|
Connect a PT100 RTD 3 wire probe to this thermometer and clearly read the large backlit digital display. Output your readings via 4 to 20mA, 0 to 5 or 5 to 10 Vdc.
Product Number | Sensor Type | Minimum Temperature Measurement | Maximum Temperature Measurement | Connection Type | Display Type | Accuracy Value | Resolution | Stem Length | Dial Diameter | Battery Type | Measurement Type | Connection Gender | Retransmission/Analog Output | Communications Protocol | Features | Weight |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Pt100 RTD
|
-51°C (-60°F)
|
538°C (1000°F)
|
Internal terminal block connection
|
LCD with selectable backlight
|
±0.2°C (±0.3°F) or ±0.1% of reading
|
0.1°C (0.1°F)
|
Not Applicable
|
Not Applicable
|
Lithium
|
Temperature
|
Not Applicable
|
User selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA Requires external 12 to 24 Vdc power supply for operation
|
USB
|
Standard
|
0.72 Kg (1.59 lb)
|
|
Pt100 RTD
|
-51°C (-60°F)
|
538°C (1000°F)
|
Internal terminal block connection
|
LCD with selectable backlight
|
±0.2°C (±0.3°F) or ±0.1% of reading
|
0.1°C (0.1°F)
|
Not Applicable
|
Not Applicable
|
Lithium
|
Temperature
|
Not Applicable
|
User selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA Requires external 12 to 24 Vdc power supply for operation
|
USB
|
Wireless transmitter option
|
0.72 Kg (1.59 lb)
|
|
Pt100 RTD
|
-51°C (-60°F)
|
538°C (1000°F)
|
Internal terminal block connection
|
LCD with selectable backlight
|
±0.2°C (±0.3°F) or ±0.1% of reading
|
0.1°C (0.1°F)
|
Not Applicable
|
Not Applicable
|
Lithium
|
Temperature
|
Not Applicable
|
User selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA Requires external 12 to 24 Vdc power supply for operation
|
USB
|
Angle bracket option
|
0.72 Kg (1.59 lb)
|
|
Pt100 RTD
|
-51°C (-60°F)
|
538°C (1000°F)
|
M12 connection
|
LCD with selectable backlight
|
±0.2°C (±0.3°F) or ±0.1% of reading
|
0.1°C (0.1°F)
|
Not Applicable
|
Not Applicable
|
Lithium
|
Temperature
|
Female
|
User selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA Requires external 12 to 24 Vdc power supply for operation
|
USB
|
Standard
|
0.72 Kg (1.59 lb)
|
|
Pt100 RTD
|
-51°C (-60°F)
|
538°C (1000°F)
|
M12 connection
|
LCD with selectable backlight
|
±0.2°C (±0.3°F) or ±0.1% of reading
|
0.1°C (0.1°F)
|
Not Applicable
|
Not Applicable
|
Lithium
|
Temperature
|
Male
|
User selectable 0 to 5 Vdc, 0 to 10 Vdc, or 4 to 20 mA Requires external 12 to 24 Vdc power supply for operation
|
USB
|
Standard
|
0.72 Kg (1.59 lb)
|