1 Channel High Accuracy 0.1% Type K, J, T Thermocouple Meter
Single J/K/T Input Thermocouple Thermometer
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-4 | $110.18 |
5-9 | $104.67 |
10-24 | $102.47 |
25-49 | $98.06 |
50-99 | $95.86 |
100+ | $93.65 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
- Auto Power-Off with Disable Feature (15 Minutes)
- Single Thermocouple Input
- Large LCD Screen
- Data Hold Function Freeze Readings on Display.
- Maximum/Minimum Record for Each Power on Cycle
- ºC or ºF Select Function
- Low Battery Indicator

Edit Options
View all modelsNot all combinations are valid. Options compatible with previous selections will be in bold.
*Highlighted options are not compatible. Please select a different combination.
Category
Input Type
Minimum Temperature Measurement
Maximum Temperature Measurement
Input Connection Type
Display Type
Accuracy Value
Resolution
Supply Power
Number of Channels
Features
Product Specs
Description
The HH-25U handheld thermocouple thermometers feature Type K, J, T thermocouple inputs and are available in single input models. The HH-25U is a single-input model that has an auto range resolution of 0.1 or 1°. are °C/°F switchable, and maximum/Minimum reading/display hold functions and low battery indicator. Offered at an economical price.Specifications
Input: Single K/J/T
Temperature Range K: -200 to 1370ºC (-328 to 2498ºF)
Resolution (K): 0.1ºC (0.1ºF), over 1000ºC 1ºC/1ºF
Accuracy (K): ±(0.1% rdg + 0.5°C) for -50 to 1370°C others ±(0.1% rdg + 2°C)
Temperature Range J: -80 to 760ºC (-112 to 1400ºF)
Accuracy (J): ±1% of rdg + 1ºC/2ºF
Temperature Range T: -80 to 400ºC (-112 to 752ºF)
Accuracy (T): ±1% of rdg + 1% 200 to 400ºC, others ±0.4% rdg + 0.6 ºC/1.2ºF
Temperature Coefficient: 0.1 times the applicable accuracy specification per °C from 0 to 18°C and 28 to 50°C (32 to 64°F and 82 to 122°F)
Function: Max/Min. hold
Power: 9V battery
Dimensions: 159 L x 55 W x 38 D mm (6.25 x 2.16 x 1.49")
Weight: 170 g (6 oz)
Operating Temperature: -10 to 50ºC (14 to 122ºF)
My unit is stuck at 1400 reading. Is this a common issue that can be fixed?
Thank you for your inquiry. Keep in mind, that Temperature Range J is -80 to 760ºC (-112 to 1400ºF)
Date published: 2020-10-01
What kind of thermocouple does it come with?
The HH25U does not come with a Thermocouple so you can search the 5SC or 5SRTC series for wire probes with the appropriate connector.
Date published: 2020-03-13
where are the other specs on this unit? Accuracy per TC type, measurement rate, etc.
Thank you for your question.
Specifications for this unit are below:
Input: Single K/J/T
Temperature Range K:
-200 to 1370ºC (-328 to 2498ºF)
Resolution (K): 0.1ºC (0.1ºF), over 1000ºC 1ºC/1ºF
Accuracy (K): ±(0.1% rdg + 0.5°C) for -50 to 1370°C; others ±(0.1% rdg + 2°C)
Temperature Range J: -80 to 760ºC
(-112 to 1400ºF)
Accuracy (J): ±1% of rdg + 1ºC/2ºF
Temperature Range T: -80 to 400ºC (-112 to 752ºF)
Accuracy (T): ±1% of rdg + 1%
200 to 400ºC, others ±0.4% rdg
+ 0.6 ºC/1.2ºF
Temperature Coefficient: 0.1 times the applicable accuracy specification per °C from 0 to 18°C and
28 to 50°C (32 to 64°F and
82 to 122°F)
Function: Max/Min. hold
Power: 9V battery
Dimensions: 159 L x 55 W x 38 D mm
(6.25 x 2.16 x 1.49")
Weight: 170 g (6 oz)
Operating Temperature:
-10 to 50ºC (14 to 122ºF)
Date published: 2019-07-03