text.skipToContent text.skipToNavigation

1 Channel High Precision Handheld RTD with Probe Datalogger

Precision RTD Handheld Data Logger Thermometer

$375.57

Item# HH376

 This item is available for quick shipping
Volume discounts available
Volume Discount Schedule
Quantity Price each
1-4 $375.57
5-9 $356.79
10-24 $349.28
25-49 $334.26
50-99 $326.75
100+ $319.23

In stock

Lead Time ( If not in Stock): 2 weeks

Precision RTD Handheld Data Logger Thermometer HH376 HH376
  • High Accuracy with 0.01C/F Resolution
  • Large Backlit Dual LCD Display
  • MAX/MIN/HOLD Function
  • 16,000 Record Data Logger
  • USB Cable Included
  • Windows Software
  • Auto Power Off
  • User Offset Adjustable
  • Low Battery Indicator
  • Tilt Stand
  • Precision 4 Wire 100 Ω Platinum RTD Probe Included
5 Year Warranty

Edit Options

View all models

Not all combinations are valid. Options compatible with previous selections will be in bold.

*Highlighted options are not compatible. Please select a different combination.

Measurement Type
Input Type
Maximum Samples
Display
Power
Data Interface
Max Sampling Rate
Additional Feature


Product Specs

The HH376 is a high accuracy RTD thermometer plus a powerful data logger. The unit can store up to 16,000 records at programmed intervals. Windows® based software and USB interface cable are included to allow real time or recorded data to be read by a PC through the USB or RS232 port (RS232 cable is optional). HH376 is supplied with a precision 4-wire RTD probe with automatic locked push-pull connector for easy connection.

SPECIFICATIONS
Instrument
Numerical Display:
5-digit LCD
Measurement Range: -100 to 400°C (-148 to 752°F)
Resolution: 0.01°C (0.02°F)
Sensor Types: Platinum resistance temperature sensor for pt-100 4 wires, ALPHA = 0.00385

Environmental
Operating Temperature and Humidity:
0 to 50°C (32 to 122°F); 0 to 80% RH
Storage Temperature: -10 to 60°C (14 to 140°F); 0 to 80% RH; altitude up to 2000 meters
Accuracy: At (23 ±5°C)
Range Accuracy: -100 to 400°C ±(0.05% reading + 0.1°C); -148 to 752°F ±(0.05% reading + 0.2°F)
Temperature Coefficient: For ambient temperatures from 0 to 18°C and 28 to 50°C, for each °C ambient below 18°C or above 28°C add the following tolerance into the accuracy spec. 0.005% of reading + 0.01°C (0.005% of reading + 0.02°F)
Sample Rate: 2 times per second
Dimensions: 185 L x 65 W x 36 mm D (meter only)
Weight: 360 g approx.
Power Requirement: 9V battery (included)
AC Adaptor: 9 Vdc (7 to 10V max)/20 mA
min (plug diameter: 3.5 x 1.35 mm)
Battery Life: Approx. 100 hrs

Probe
Sensor Type:
Pt100 (4 wire)
Accuracy: Class A13, temperature probe
Measurement Range: -100 to 400°C (-148 to 752°F)
Sheath Diameter: 5.0 mm (0.2')
Sheath Length: 230 mm (9.05')
Cable Length: 1500 mm (59.0')

Rated 5 out of 5 by from Very accurate instrument After using numerous instruments to measure pipeline temperatures, I have finally found the device that accurately does.
Date published: 2017-11-28
Rated 5 out of 5 by from High accuracy and inexpensive Great little handheld with 2 digits of precision after the decimal. Data logging for charting responses, easy connect to computer for download of data. We use it to monitor differential temps near 100C and it’s very repeatable. Also nice is the 120V adapter so no worry about battery life. Highly recommend.
Date published: 2018-06-09
Rated 5 out of 5 by from Price quality Price Quality, Practical dan easy to use. I will give good use.
Date published: 2018-01-08
  • y_2021, m_9, d_25, h_20
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.19
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_3
  • loc_en_US, sid_HH376, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getReviews, 10ms
  • REVIEWS, PRODUCT

At (23 ±5°C) : Range Accuracy: -100 to 400°C ±(0.05% reading + 0.1°C); -148 to 752°F ±(0.05% reading + 0.2°F) Is accuracy unit and probe, or unit only?

Asked by: DavNH
Hi DavNH, Thank you for the inquiry. Accuracy is for the meter only. Probe is accuracy class A ( 0.15 C +/- 0.2 % of reading) Best regards OMEGA
Answered by: NorwalkAE
Date published: 2020-05-27

Is there an equivalent OTS connector for this device? I am looking to create my own probe and the omega connector is out of stock.

Asked by: jsapers
Omega does not sell the connector as an accessory and only the entire probe is sold separately. Omega does not have the part number to buy the connector from another source.
Answered by: Application Engineer AB
Date published: 2021-06-22
  • y_2021, m_9, d_25, h_20CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.19
  • cp_2, bvpage2n
  • co_hasquestionsanswers, tq_10
  • loc_en_US, sid_HH376, prod, sort_[SortEntry(order=NUM_ANSWERS, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 14ms
  • QUESTIONS, PRODUCT
Accessories
Precision 4 wire RTD probe (spare)
$89.50
11 In Stock
Power adaptor (115 Vac)
$19.91
44 In Stock
RS232 interface cable
$19.91
10 In Stock
Spare USB interface cable
$19.91
7 In Stock

en-US
en
Save Configuration