text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

1 or 2 Channel, 12" (305mm) Circular Chart Recorder with Programmable Inputs

Item# CT8100

1 or 2 Channel, 12 1 or 2 Channel, 12" (305mm) Circular Chart Recorder with Programmable Inputs
The CT8000 Series Circular Chart Recorder/Controller measures, displays and controls up to two process variables. Choose from a variety of programmable inputs. All recorder, control and alarm functions are easily configured via front key pad with self-prompting displays. Two user configurable alarm settings are provided for each pen. Optional control capability as well as RS-485 and NEMA-4X are available. Control outputs include SSR driver, 4 to 20 mA, or relays. In addition, the 4-20 mA option can be used for retransmitting the process value.
CT8100
  • 305 mm (12") Chart
  • 1- or 2-Pen Versions
  • Programmable Inputs, Thermocouple, RTD, dc Current or Voltage
  • Control Outputs
  • 4-Digit 14 mm (0.56") Display Per Pen
Number of Pens
Chart Rotation Time
Number of Channels
Number of Alarm Relays
Features
See All Options
Quantity Price each
1-4 $1,785.00
5-9 $1,695.75
10-24 $1,660.05
25-49 $1,588.65
50-99 $1,552.95
100+ $1,517.25

In stock

Lead Time ( If not in Stock): 5 weeks

Product Specs

  • Accuracy Value ±0.1% to 20 mA span reference accuracy
  • Alarm Notes Alarms work normally in “HI” and “LO” conditions
  • Alarm Security Alarm setpoint changes can be prohibited
  • Alarm Type Recorder: Process high or low. Controllers: Process
  • Analog Voltage Input Ranges 0 to 25 mV
  • Battery Backup 5 years minimum life
  • Chart Accuracy ±0.5% of rotation time
  • Chart Drive Stepper motor
  • Chart Rotation Accuracy ±0.5% of rotation time
  • Enclosure Material Gasketed cover
  • Display Area Height 14 mm
  • Form Factor Panel or wall
  • Hybrid Display Yes
  • Maximum Ambient Temperature 55 {C} (131 {F})
  • Maximum Ambient Humidity 90% RH Non-Condensing
  • Maximum Storage Temperature 65 {C} (149 {F})
  • Minimum Ambient Temperature 0 {C} (32 {F})
  • Minimum Ambient Humidity 10% RH
  • Minimum Storage Temperature -40 {C}
  • Number of Conduit Openings 4 openings standard
  • Power 25 VA max
  • Recorder Type Circular
  • Relay Type SPDT
  • Resolution 0.5% of chart span reference accuracy
  • RTD Types Supported 100 Ω Platinum

The CT8000 Series Circular Chart Recorder/Controller measures, displays and controls up to two process variables. Choose from a variety of programmable inputs. All recorder, control and alarm functions are easily configured via front key pad with self-prompting displays. Two user configurable alarm settings are provided for each pen. Optional control capability as well as RS-485 and NEMA-4X are available. Control outputs include SSR driver, 4 to 20 mA, or relays. In addition, the 4-20 mA option can be used for retransmitting the process value.

  • CE Icon CE

en-US
en
Save Configuration