Solid-State Relays for Intrinsic Safety up to 5A max.
Solid-State Relays for Intrinsic Safety
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-4 | $278.17 |
5-9 | $264.26 |
10-24 | $258.70 |
25-49 | $247.57 |
50-99 | $242.01 |
100+ | $236.44 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
- Rapid, Arc-Free Response for Positive, Non-Mechanical Operation
- Solid-State Reliability to Insure Consistent Performance
- Low-Power Switching where a Few Milliamps of Current Control High-Power Loads
- Completely Encapsulated Construction Impervious to Dust, Moisture or Foreign Material
- Standardized, Modular Housings for Easier Installation
- Exceptionally Long, Trouble-Free Service Life
- Latching and Non-Latching Models
SBG25873A Model Options
View all modelsEdit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.
*Highlighted options are not compatible. Please select a different combination.
AC Line Voltage
Nominal Load Current
Features
Control Signal Type
Solid-State Relay:
Less than 100 microamps at 14 Vdc actuates the unit to control ac loads to 5 amps at 120 Vac. Resistive (up to 400,000 ohms) or short-circuiting sensors operate the unit. 115 Vac and 230 Vac models.
Latching Solid-State Relay:
Momentary actuation, “start-stop” or differential control switching for resistive loads to 0.3 amps, 115 Vac model. OMEGA™ solid-state relays for intrinsic safety allow non-voltage producing switches mounted in the hazardous area to safely control higher power ac loads in the nonhazardous area. Typical applications include flow, level and pressure switches which may be inputs to an alarm or control system.
![]()
Note 1: For typical wiring diagrams, see next page.
Note 2: All ac voltage and current specifications are RMS values unless otherwise stated.
Note 3: Housing material is Polysulfone.
Less than 100 microamps at 14 Vdc actuates the unit to control ac loads to 5 amps at 120 Vac. Resistive (up to 400,000 ohms) or short-circuiting sensors operate the unit. 115 Vac and 230 Vac models.
Latching Solid-State Relay:
Momentary actuation, “start-stop” or differential control switching for resistive loads to 0.3 amps, 115 Vac model. OMEGA™ solid-state relays for intrinsic safety allow non-voltage producing switches mounted in the hazardous area to safely control higher power ac loads in the nonhazardous area. Typical applications include flow, level and pressure switches which may be inputs to an alarm or control system.
Model No. | Description | Line & Load Voltage Range | Load Current Max | Turn-On Sensitivity (Typical) | Turn-Off Sensitivity (Typical) | Voltage Loss | Operating Temperature Range | Output Leakage Current Max. | Switching Operation |
SBG22445A | SSR for Intrinsic Safety | 95 to 135 Vac | 5A | <=400 K Ω | 1 meg. Ω | 2 Vac | 0° to +120°F | 6 mA @ 120 Vac | SPST N.O. |
SBG25872A | 100 to 135 Vac | 6 mA @ 120 Vac | SPST N.C. | ||||||
SBG25873A | 200 to 250 Vac | 12 mA @ 250 Vac | SPST N.O. | ||||||
SBG41705A | Latching SSR for Intrinsic Safety | 105 to 125 Vac | 0.3 A Steady State | <=25 K Ω | 1 meg. Ω | 2 Vac | +32° to +°120°F | 3 mA @ 120 Vac | SPST N.O. |
Note 2: All ac voltage and current specifications are RMS values unless otherwise stated.
Note 3: Housing material is Polysulfone.