PST joins DwyerOmega. Read more>
The FMG470 Series is the most economical flanged electromagnetic flowmeter on the market. With electrodes designed to discourage fouling, it is available in 2" to 12" flange sizes.
Product Number | Flow Range | Velocity Range | Accuracy | Max Operating Pressure | Max Process Temperature | Wetted Materials | Media Type | Output Signal | Supply Power | Process Connection Type | Process Connection Size | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
723 GPM (46 LPS)
|
10 MPS
|
±1%
|
150 psi
|
60C (140F)
|
316 SS, Noryl, EPDM
|
Conductive Fluids
|
Current sinking pulse
|
7.2V 'D' Lithium Battery
|
ANSI Flange
|
3"
|
Must Choose one of the 4 PIN Cables From Accessories
|
|
723 GPM (46 LPS)
|
10 MPS
|
±1%
|
150 psi
|
60C (140F)
|
316 SS, Noryl, EPDM
|
Conductive Fluids
|
Current sinking pulse, 4 to 20 mA
|
9 to 36 Vdc / 60 Hz
|
ANSI Flange
|
3"
|
Must Choose one of the 8 PIN Cables From Accessories
|
|
723 GPM (46 LPS)
|
10 MPS
|
±1%
|
150 psi
|
60C (140F)
|
316 SS, Noryl, EPDM
|
Conductive Fluids
|
Current sinking pulse
|
9 to 36 Vdc / 60 Hz
|
ANSI Flange
|
3"
|
Must Choose one of the 4 PIN Cables From Accessories
|
|
1285 GPM (81 LPS)
|
10 MPS
|
±1%
|
150 psi
|
60C (140F)
|
316 SS, Polypropylene, EPDM
|
Conductive Fluids
|
Current sinking pulse
|
7.2V 'D' Lithium Battery
|
ANSI Flange
|
4"
|
Must Choose one of the 4 PIN Cables From Accessories
|
|
1285 GPM (81 LPS)
|
10 MPS
|
±1%
|
150 psi
|
60C (140F)
|
316 SS, Polypropylene, EPDM
|
Conductive Fluids
|
Current sinking pulse, 4 to 20 mA
|
9 to 36 Vdc / 60 Hz
|
ANSI Flange
|
4"
|
Must Choose one of the 8 PIN Cables From Accessories
|
Product Number | Display | Communication Type | Applicable Pipe Size |
---|---|---|---|
|
NONE
|
BACnet MS/TP or Modbus® RTU
|
4 to 36" (100 to 900 mm)
|
|
NONE
|
NONE
|
4 to 10" (100 to 250 mm)
|
|
NONE
|
NONE
|
4 to 36" (100 to 900 mm)
|
|
NONE
|
BACnet MS/TP or Modbus® RTU
|
8" (200 mm)
|
|
NONE
|
BACnet MS/TP or Modbus® RTU
|
4" (100 mm)
|
Product Number | Accuracy | Wetted Materials | Display | Service: | Range: | Temperature Limits: | Process Connection: | Pressure Limits: | Pressure Drop: | Communication Type: | Applicable Pipe Size: |
---|---|---|---|---|---|---|---|---|---|---|---|
|
High Accuracy Class 2**
|
316 SS
|
LCD
|
Clean Liquids
|
0 to 20 ft/s (0 to 6 m/s).
|
up to 250°F (121°C)
|
1" BSPT
|
up to 400 psi (27.6 bar)
|
< 0.1 psi
|
none
|
8" (200 mm)
|
|
High Accuracy Class 2**
|
316 SS
|
LCD
|
Clean Liquids
|
0 to 20 ft/s (0 to 6 m/s).
|
up to 250°F (121°C)
|
1" BSPT
|
up to 400 psi (27.6 bar)
|
< 0.1 psi
|
none
|
4" (100 mm)
|
|
High Accuracy Class 2**
|
316 SS
|
LCD
|
Clean Liquids
|
0 to 20 ft/s (0 to 6 m/s).
|
up to 250°F (121°C)
|
1" BSPT
|
up to 400 psi (27.6 bar)
|
< 0.1 psi
|
none
|
4 to 36" (100 to 900 mm)
|
|
High Accuracy Class 2**
|
316 SS
|
LCD
|
Clean Liquids
|
0 to 20 ft/s (0 to 6 m/s).
|
up to 250°F (121°C)
|
1" BSPT
|
up to 400 psi (27.6 bar)
|
< 0.1 psi
|
none
|
4 to 36" (100 to 900 mm)
|
|
High Accuracy Class 2**
|
316 SS
|
LCD
|
Clean Liquids
|
0 to 20 ft/s (0 to 6 m/s).
|
up to 250°F (121°C)
|
1" BSPT
|
up to 400 psi (27.6 bar)
|
< 0.1 psi
|
none
|
6" (150 mm)
|
The FMG-550 Series Magmeters are heavy-duty, high-performance sensors in an adjustable, insertion configuration that can be used with a ball valve for hot-tap installations.
Product Number | Category | Velocity Range | Accuracy | Max Operating Pressure | Max Process Temperature | Wetted Materials | Media Type | Output Signal | Supply Power | Display | Compatible Fittings | Pipe Size Range |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
0.15 to 33 FPS
|
±2%
|
300 psi
|
85 °C (185 °F)
|
316 SS, PVDF, FKM
|
Conductive Fluids
|
4 to 20 mA
|
21.6 to 26.4 Vdc
|
No Display
|
Standard 1 1/4" NPT Tee Adaptors, Customer Supplied
|
2 to 48"
|
|
Meter
|
0.15 to 33 FPS
|
±2%
|
300 psi
|
85 °C (185 °F)
|
316 SS, PVDF, FKM
|
Conductive Fluids
|
Amplified Square Wave
|
5 to 24 Vdc
|
No Display
|
Standard 1 1/4" NPT Tee Adaptors, Customer Supplied
|
2 to 48"
|
Picomag. The compact alternative to a mechanical flowmeter. No moving parts, simple to install, maintenance free, high performance.
Product Number | Flow Range | Accuracy | Max Operating Pressure | Max Process Temperature | Wetted Materials | Media Type | Output Signal | Supply Power | Compatible Fittings | Process Connection Type | Process Connection Size | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0.03 to 13.2 gal/min (0.1 to 50 l/min)
|
+/- 0.8%
|
232 psi (16 bar)
|
158F (70C)[1 hr @ 212F]*
|
316L SS, FKM, PEEK
|
Conductive Fluids
|
Pulse, Current, Voltage
|
18 to 30 Vdc
|
Not Required
|
NPTF
|
3/4"
|
Bluetooth, IO-Link, simultanious measurement of flow, temperature, and conductivity
|
|
0.01 to 6.6 gal/min (0.05 to 25 l/min)
|
+/- 0.8%
|
232 psi (16 bar)
|
158F (70C)[1 hr @ 212F]*
|
316L SS, FKM, PEEK
|
Conductive Fluids
|
Pulse, Current, Voltage
|
18 to 30 Vdc
|
Choose From Accessories
|
BSPP
|
1/2"
|
Bluetooth, IO-Link, Adapter set for thread options, simultanious measurement of flow, temperature, and conductivity
|
|
0.01 to 6.6 gal/min (0.05 to 25 l/min)
|
+/- 0.8%
|
232 psi (16 bar)
|
158F (70C)[1 hr @ 212F]*
|
316L SS, FKM, PEEK
|
Conductive Fluids
|
Pulse, Current, Voltage
|
18 to 30 Vdc
|
Not Required
|
NPTF
|
1/2"
|
Bluetooth, IO-Link, simultanious measurement of flow, temperature, and conductivity
|
|
0.03 to 13.2 gal/min (0.1 to 50 l/min)
|
+/- 0.8%
|
232 psi (16 bar)
|
158F (70C)[1 hr @ 212F]*
|
316L SS, FKM, PEEK
|
Conductive Fluids
|
Pulse, Current, Voltage
|
18 to 30 Vdc
|
Choose From Accessories
|
BSPP
|
3/4"
|
Bluetooth, IO-Link, Adapter set for thread options, simultanious measurement of flow, temperature, and conductivity
|
|
0.05 to 26.4 gal/min (0.2 to 100 l/min)
|
+/- 0.8%
|
232 psi (16 bar)
|
158F (70C)[1 hr @ 212F]*
|
316L SS, FKM, PEEK
|
Conductive Fluids
|
Pulse, Current, Voltage
|
18 to 30 Vdc
|
Choose From Accessories
|
BSPP
|
1"
|
Bluetooth, IO-Link, Adapter set for thread options, simultanious measurement of flow, temperature, and conductivity
|
The FMG3000 Series magmeters are insertion-style magnetic flow sensors with no moving parts. All models are constructed of corrosion-resistant materials.
Product Number | Category | Velocity Range | Accuracy | Max Operating Pressure | Max Process Temperature | Wetted Materials | Media Type | Output Signal | Supply Power | Display | Compatible Fittings | Pipe Size Range | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
0.15 to 16.4 FPS
|
±1%
|
150 psi
|
85 °C (185 °F)
|
316 SS, PP, FKM
|
Conductive Fluids
|
Amplified Square Wave
|
4.5 to 26.4 Vdc
|
No Display
|
FP-5300 Sensor Installation Fittings, User Must Select
|
1/2 to 4"
|
NEMA 4X, IP67
|
|
Meter
|
0.15 to 16.4 FPS
|
±1%
|
150 psi
|
85 °C (185 °F)
|
316 SS, PP, FKM
|
Conductive Fluids
|
4 to 20 mA
|
21.6 to 26.4 Vdc
|
No Display
|
FP-5300 Sensor Installation Fittings, User Must Select
|
1/2 to 4"
|
NEMA 4X, IP67
|
|
Meter
|
0.15 to 16.4 FPS
|
±1%
|
150 psi
|
85 °C (185 °F)
|
316 SS, PP, FKM
|
Conductive Fluids
|
Amplified Square Wave
|
4.5 to 26.4 Vdc
|
No Display
|
FP-5300 Sensor Installation Fittings, User Must Select
|
5 to 8"
|
NEMA 4X, IP67
|
|
Meter
|
0.15 to 16.4 FPS
|
±1%
|
150 psi
|
85 °C (185 °F)
|
316 SS, PP, FKM
|
Conductive Fluids
|
4 to 20 mA
|
21.6 to 26.4 Vdc
|
No Display
|
FP-5300 Sensor Installation Fittings, User Must Select
|
5 to 8"
|
NEMA 4X, IP67
|
|
Meter
|
0.15 to 16.4 FPS
|
±1%
|
150 psi
|
85 °C (185 °F)
|
316 SS, PP, FKM
|
Conductive Fluids
|
Amplified Square Wave, 5A SPDT Relay
|
4.5 to 26.4 Vdc
|
LCD
|
FP-5300 Sensor Installation Fittings, User Must Select
|
1/2 to 4"
|
NEMA 4X, IP67
|
The FMG2000 Series has been discontinued and replaced by the FMG470 Series
The FMG90B Series electro-magnetic flow sensor for conductive liquid media was developed for OEM applications and does not contain any moving parts.
Product Number | Category | Flow Range | Accuracy | Max Operating Pressure | Max Process Temperature | Wetted Materials | Media Type | Output Signal | Supply Power / Frequency | Process Connection Type | Process Connection Size | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
0.026 to .53 GPM
|
+/- 0.7%
|
145 psi @ 68F
|
140F (60C)
|
SS, PVDF, EPDM
|
Conductive Fluids
|
0.5 to 10 V
|
12 to 24 Vdc
|
NPTM
|
3/8"
|
Compact lightweight construction, No moving parts
|
|
Meter
|
0.26 to 5.3 GPM
|
+/- 0.7%
|
145 psi @ 68F
|
140F (60C)
|
SS, PVDF, EPDM
|
Conductive Fluids
|
0.5 to 10 V
|
12 to 24 Vdc
|
BSPP
|
1/2"
|
Compact lightweight construction, No moving parts
|
|
Meter
|
0.026 to .53 GPM
|
+/- 0.7%
|
145 psi @ 68F
|
140F (60C)
|
Hastelloy C, PVDF, FKM
|
Conductive Fluids
|
4 to 20 mA
|
12 to 24 Vdc
|
BSPP
|
3/8"
|
Compact lightweight construction, No moving parts
|
|
Meter
|
0.026 to .53 GPM
|
+/- 0.7%
|
145 psi @ 68F
|
140F (60C)
|
Hastelloy C, PVDF, FKM
|
Conductive Fluids
|
4 to 20 mA
|
12 to 24 Vdc
|
NPTM
|
3/8"
|
Compact lightweight construction, No moving parts
|
|
Meter
|
0.026 to .53 GPM
|
+/- 0.7%
|
145 psi @ 68F
|
140F (60C)
|
Hastelloy C, PVDF, FKM
|
Conductive Fluids
|
Amplified Square Wave
|
12 to 24 Vdc
|
BSPP
|
3/8"
|
Compact lightweight construction, No moving parts
|
The complete lack of moving parts of this insertion flow sensor is the source of its reliability. Brass and stainless steel models withstand a variety of conditions.
Product Number | Category | Velocity Range | Accuracy | Max Operating Pressure | Max Process Temperature | Wetted Materials | Media Type | Output Signal | Supply Power | Display | Compatible Fittings | Pipe Size Range |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
0.28 to 20 FPS
|
±1%
|
200 psi
|
93 °C (200 °F)
|
Brass, Hastelloy, PVDF, EPDM
|
Conductive Fluids
|
Amplified Square Wave
|
12 to 24 Vdc
|
No Display
|
Standard 1 1/2" NPT Tee Adaptors, Customer Supplied
|
3 to 10"
|
|
Meter
|
0.28 to 20 FPS
|
±1%
|
200 psi
|
93 °C (200 °F)
|
Brass, Hastelloy, PVDF, EPDM
|
Conductive Fluids
|
Amplified Square Wave
|
12 to 24 Vdc
|
No Display
|
Standard 1 1/2" NPT Tee Adaptors, Customer Supplied
|
10 to 48"
|
|
Meter
|
0.28 to 20 FPS
|
±1%
|
200 psi
|
93 °C (200 °F)
|
316 SS, Hastelloy, PVDF, EPDM
|
Conductive Fluids
|
Amplified Square Wave
|
12 to 24 Vdc
|
No Display
|
Standard 1 1/2" NPT Tee Adaptors, Customer Supplied
|
3 to 10"
|
|
Meter
|
0.28 to 20 FPS
|
±1%
|
200 psi
|
93 °C (200 °F)
|
316 SS, Hastelloy, PVDF, EPDM
|
Conductive Fluids
|
Amplified Square Wave
|
12 to 24 Vdc
|
No Display
|
Standard 1 1/2" NPT Tee Adaptors, Customer Supplied
|
10 to 48"
|
|
Meter
|
0.28 to 20 FPS
|
±1%
|
200 psi
|
93 °C (200 °F)
|
Brass, Bronze, Hastelloy, PVDF, EPDM
|
Conductive Fluids
|
Amplified Square Wave
|
12 to 24 Vdc
|
No Display
|
Standard 2" NPT Tee Adaptors, Customer Supplied
|
3 to 10"
|
The FMG480 Series is used in municipal or industrial water, waste and reclaimed water, pump stations, and packaged plant applications.
Product Number | Category | Flow Range | Velocity Range | Accuracy | Max Operating Pressure | Max Process Temperature | Wetted Materials | Media Type | Output Signal | Supply Power | Display | Process Connection Type | Process Connection Size | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
723 GPM (46 LPS)
|
10 MPS
|
±0.75%
|
150 psi
|
60C (140F)
|
316 SS, Noryl, EPDM
|
Conductive Fluids
|
Current sinking pulse, 4 to 20 mA
|
85 to 264 Vac, 50/60 Hz
|
LCD
|
ANSI Flange
|
3"
|
Must Select 8 Conductor Output Cable From Accessories
|
|
Meter
|
723 GPM (46 LPS)
|
10 MPS
|
±0.75%
|
150 psi
|
60C (140F)
|
316 SS, Noryl, EPDM
|
Conductive Fluids
|
Current sinking pulse, 4 to 20 mA
|
85 to 264 Vac, 50/60 Hz
|
LCD
|
ANSI Flange
|
3"
|
Must Select 8 Conductor Output Cable From Accessories
|
|
Meter
|
723 GPM (46 LPS)
|
10 MPS
|
±0.75%
|
150 psi
|
60C (140F)
|
316 SS, Noryl, EPDM
|
Conductive Fluids
|
Current sinking pulse, 4 to 20 mA
|
9 to 36 Vdc / 50 Hz
|
LCD
|
ANSI Flange
|
3"
|
Must Select 8 Conductor Output Cable From Accessories
|
|
Meter
|
723 GPM (46 LPS)
|
10 MPS
|
±0.75%
|
150 psi
|
60C (140F)
|
316 SS, Noryl, EPDM
|
Conductive Fluids
|
Current sinking pulse, 4 to 20 mA
|
9 to 36 Vdc / 60 Hz
|
LCD
|
ANSI Flange
|
3"
|
Must Select 8 Conductor Output Cable From Accessories
|
|
Meter
|
1285 GPM (81 LPS)
|
10 MPS
|
±0.75%
|
150 psi
|
60C (140F)
|
316 SS, Polypropylene, EPDM
|
Conductive Fluids
|
Current sinking pulse, 4 to 20 mA
|
85 to 264 Vac, 50/60 Hz
|
LCD
|
ANSI Flange
|
4"
|
Must Select 8 Conductor Output Cable From Accessories
|
The FMG600 Series electromagnetic flow meters are designed for measurement of conductive liquids. The FMG600 magmeters have no moving parts and a PTFE lining.
Product Number | Category | Flow Range | Accuracy | Max Operating Pressure | Max Process Temperature | Wetted Materials | Media Type | Output Signal | Communication Protocol | Supply Power | Display | Process Connection Type | Process Connection Size | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
5.2 to 52 GPM
|
±0.5%
|
145 psi
|
50 °C (122 °F)
|
Hastelloy, PTFE
|
Conductive Fluids
|
4 to 20 mA, Amplified Square Wave
|
RS485
|
24 Vdc
|
LCD
|
ANSI Flange
|
3/4"
|
Not Applicable
|
|
Meter
|
7.9 to 79 GPM
|
±0.5%
|
145 psi
|
50 °C (122 °F)
|
Hastelloy, PTFE
|
Conductive Fluids
|
4 to 20 mA, Amplified Square Wave
|
RS485
|
24 Vdc
|
LCD
|
ANSI Flange
|
1"
|
NIST Calibration
|
|
Meter
|
13.2 to 132 GPM
|
±0.5%
|
145 psi
|
50 °C (122 °F)
|
Hastelloy, PTFE
|
Conductive Fluids
|
4 to 20 mA, Amplified Square Wave
|
RS485
|
24 Vdc
|
LCD
|
ANSI Flange
|
1 1/4"
|
NIST Calibration
|
|
Meter
|
19.8 to 198 GPM
|
±0.5%
|
145 psi
|
50 °C (122 °F)
|
Hastelloy, PTFE
|
Conductive Fluids
|
4 to 20 mA, Amplified Square Wave
|
RS485
|
24 Vdc
|
LCD
|
ANSI Flange
|
1 1/2"
|
NIST Calibration
|
|
Meter
|
31.7 to 317 GPM
|
±0.5%
|
145 psi
|
50 °C (122 °F)
|
Hastelloy, PTFE
|
Conductive Fluids
|
4 to 20 mA, Amplified Square Wave
|
RS485
|
24 Vdc
|
LCD
|
ANSI Flange
|
2"
|
NIST Calibration
|
The FMG800 Series is a full-bore, plastic-bodied electromagnetic flow meter designed for flow and usage monitoring applications in 1, 2 and 3 inch pipe.
Product Number | Category | Flow Range | Accuracy | Max Operating Pressure | Max Process Temperature | Wetted Materials | Media Type | Output Signal | Supply Power | Display | Process Connection Type | Process Connection Size |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
2.3 to 110 GPM
|
±1%
|
150 psi
|
54 °C (130 °F)
|
316 SS, PP, Glass
|
Conductive Fluids
|
Not Applicable
|
Battery Power (6AA)
|
LCD
|
NPT Female
|
1"
|
|
Meter
|
6 to 300 GPM
|
±1%
|
150 psi
|
54 °C (130 °F)
|
316 SS, PP, Glass
|
Conductive Fluids
|
Not Applicable
|
Battery Power (6AA)
|
LCD
|
NPT Female
|
2"
|
|
Meter
|
14 to 670 GPM
|
±1%
|
150 psi
|
54 °C (130 °F)
|
316 SS, PP, Glass
|
Conductive Fluids
|
Not Applicable
|
Battery Power (6AA)
|
LCD
|
NPT Female
|
3"
|
|
Meter
|
2.3 to 110 GPM
|
±1%
|
150 psi
|
54 °C (130 °F)
|
316 SS, PP, Glass
|
Conductive Fluids
|
Amplified Square Wave
|
10 to 30 Vdc
|
LCD
|
NPT Female
|
1"
|
|
Meter
|
6 to 300 GPM
|
±1%
|
150 psi
|
54 °C (130 °F)
|
316 SS, PP, Glass
|
Conductive Fluids
|
Amplified Square Wave
|
10 to 30 Vdc
|
LCD
|
NPT Female
|
2"
|
The FMG490 Series has a remote display that can be mounted up to 200 FT from the flow meter. With electrodes designed to discourage fouling, it is available in 3" to 12" sizes.
Product Number | Category | Flow Range | Velocity Range | Accuracy | Max Operating Pressure | Max Process Temperature | Wetted Materials | Media Type | Output Signal | Supply Power | Display | Process Connection Type | Process Connection Size | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
723 GPM (46 LPS)
|
10 MPS
|
±0.75%
|
150 psi
|
60C (140F)
|
316 SS, Noryl, EPDM
|
Conductive Fluids
|
Current sinking pulse, 4 to 20 mA
|
85 to 264 Vac / 50 Hz
|
LCD
|
ANSI Flange
|
3"
|
Must Select 6 Conductor Output Cable From Accessories
|
|
Meter
|
723 GPM (46 LPS)
|
10 MPS
|
±0.75%
|
150 psi
|
60C (140F)
|
316 SS, Noryl, EPDM
|
Conductive Fluids
|
Current sinking pulse
|
85 to 264 Vac / 50 Hz
|
LCD
|
ANSI Flange
|
3"
|
Must Select 6 Conductor Output Cable From Accessories
|
|
Meter
|
723 GPM (46 LPS)
|
10 MPS
|
±0.75%
|
150 psi
|
60C (140F)
|
316 SS, Noryl, EPDM
|
Conductive Fluids
|
Current sinking pulse, 4 to 20 mA
|
86 to 264 Vac / 60 Hz
|
LCD
|
ANSI Flange
|
3"
|
Must Select 6 Conductor Output Cable From Accessories
|
|
Meter
|
723 GPM (46 LPS)
|
10 MPS
|
±0.75%
|
150 psi
|
60C (140F)
|
316 SS, Noryl, EPDM
|
Conductive Fluids
|
Current sinking pulse
|
86 to 264 Vac / 60 Hz
|
LCD
|
ANSI Flange
|
3"
|
Must Select 6 Conductor Output Cable From Accessories
|
|
Meter
|
723 GPM (46 LPS)
|
10 MPS
|
±0.75%
|
150 psi
|
60C (140F)
|
316 SS, Noryl, EPDM
|
Conductive Fluids
|
Current sinking pulse, 4 to 20 mA
|
9 to 36 Vdc / 50 Hz
|
LCD
|
ANSI Flange
|
3"
|
Must Select 6 Conductor Output Cable From Accessories
|
The FMG80A Series magmeter is designed for low-flow chemical injection or difficult-to-meter applications with pulsating metering pumps in ¼" to ¾" pipe/tube.
Product Number | Category | Flow Range | Accuracy | Max Operating Pressure | Max Process Temperature | Wetted Materials | Media Type | Output Signal | Supply Power | Display | Process Connection Type | Process Connection Size | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
0.03 to 3 GPM
|
±1%
|
150 psi
|
93 °C (200 °F)
|
PVDF
|
Conductive Fluids
|
4 to 20 mA, Amplified Square Wave
|
10 to 15 Vdc
|
No Display
|
NPT Male
|
1/4"
|
NEMA 4X, IP66
|
|
Meter
|
0.03 to 3 GPM
|
±1%
|
150 psi
|
93 °C (200 °F)
|
PVDF
|
Conductive Fluids
|
4 to 20 mA, Amplified Square Wave
|
10 to 15 Vdc
|
No Display
|
NPT Male
|
3/8"
|
NEMA 4X, IP66
|
|
Meter
|
0.2 to 20 GPM
|
±1%
|
150 psi
|
93 °C (200 °F)
|
PVDF
|
Conductive Fluids
|
4 to 20 mA, Amplified Square Wave
|
10 to 15 Vdc
|
No Display
|
NPT Male
|
1/2"
|
NEMA 4X, IP66
|
|
Meter
|
0.2 to 20 GPM
|
±1%
|
150 psi
|
93 °C (200 °F)
|
PVDF
|
Conductive Fluids
|
4 to 20 mA, Amplified Square Wave
|
10 to 15 Vdc
|
No Display
|
NPT Male
|
3/4"
|
NEMA 4X, IP66
|
The FMG70B Series from OMEGA is a trio of extremely compact, low cost, inductive magnetic flow sensors. The output signal frequency (or current) is proportional to the flow.
Product Number | Category | Flow Range | Accuracy | Max Operating Pressure | Max Process Temperature | Wetted Materials | Media Type | Output Signal | Supply Power | Display | Process Connection Type | Process Connection Size | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
0.13 to 7.93 GPM
|
±1.5%
|
232 psi
|
90 °C (194 °F)
|
316 SS, EPDM
|
Conductive Fluids
|
Amplified Square Wave
|
24 Vdc
|
No Display
|
NPT Male
|
1/2"
|
NEMA 4X, IP67
|
|
Meter
|
0.26 to 15.85 GPM
|
±1.5%
|
232 psi
|
90 °C (194 °F)
|
316 SS, EPDM
|
Conductive Fluids
|
Amplified Square Wave
|
24 Vdc
|
No Display
|
NPT Male
|
1/2"
|
NEMA 4X, IP67
|
|
Meter
|
1.32 to 66 GPM
|
±1.5%
|
232 psi
|
90 °C (194 °F)
|
316 SS, EPDM
|
Conductive Fluids
|
Amplified Square Wave
|
24 Vdc
|
No Display
|
NPT Male
|
1"
|
NEMA 4X, IP67
|
|
Meter
|
0.13 to 7.93 GPM
|
±1.5%
|
232 psi
|
90 °C (194 °F)
|
316 SS, EPDM
|
Conductive Fluids
|
4 to 20 mA
|
24 Vdc
|
No Display
|
NPT Male
|
1/2"
|
NEMA 4X, IP67
|
|
Meter
|
0.26 to 15.85 GPM
|
±1.5%
|
232 psi
|
90 °C (194 °F)
|
316 SS, EPDM
|
Conductive Fluids
|
4 to 20 mA
|
24 Vdc
|
No Display
|
NPT Male
|
1/2"
|
NEMA 4X, IP67
|
The FMG980 is highly suitable for difficult applications with changing viscosities and pulsating flows, such as air-driven diaphragm pumps.
Product Number | Category | Velocity Range | Accuracy | Max Operating Pressure | Max Process Temperature | Wetted Materials | Media Type | Output Signal | Supply Power | Display | Compatible Fittings | Pipe Size Range | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Meter
|
0.28 to 20 FPS
|
±1%
|
200 psi
|
93 °C (200 °F)
|
Brass, Hastelloy, PVDF, EPDM
|
Conductive Fluids
|
Amplified Square Wave
|
12 to 25 Vdc
|
No Display
|
FP980 Sensor Installation Fittings, User Must Select
|
1 to 3"
|
Empty Pipe Detection
|
|
Meter
|
0.28 to 20 FPS
|
±1%
|
150 psi
|
54 °C (130 °F)
|
PVC, Hastelloy, PVDF, EPDM
|
Conductive Fluids
|
Amplified Square Wave
|
12 to 25 Vdc
|
No Display
|
FP980 Sensor Installation Fittings, User Must Select
|
1 to 3"
|
Empty Pipe Detection
|
|
Meter
|
0.28 to 20 FPS
|
±1%
|
200 psi
|
93 °C (200 °F)
|
316 SS, Hastelloy, PVDF, EPDM
|
Conductive Fluids
|
Amplified Square Wave
|
12 to 25 Vdc
|
No Display
|
FP980 Sensor Installation Fittings, User Must Select
|
1 to 3"
|
Empty Pipe Detection
|
|
Meter
|
0.28 to 20 FPS
|
±1%
|
200 psi
|
93 °C (200 °F)
|
Brass, Hastelloy, PVDF, EPDM
|
Conductive Fluids
|
Amplified Square Wave
|
12 to 25 Vdc
|
No Display
|
FP980 Sensor Installation Fittings, User Must Select
|
4 to 10"
|
Empty Pipe Detection
|
|
Meter
|
0.28 to 20 FPS
|
±1%
|
150 psi
|
54 °C (130 °F)
|
PVC, Hastelloy, PVDF, EPDM
|
Conductive Fluids
|
Amplified Square Wave
|
12 to 25 Vdc
|
No Display
|
FP980 Sensor Installation Fittings, User Must Select
|
4 to 10"
|
Empty Pipe Detection
|