316 SS Turbine Flow Meters w/Pulse or Current Output
Economical Liquid Turbine Flowmeters
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-4 | $1,456.00 |
5-9 | $1,383.20 |
10-24 | $1,354.08 |
25-49 | $1,295.84 |
50-99 | $1,266.72 |
100+ | $1,237.60 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
- ±1% of Actual Flow Accuracy
- Includes 3-point NIST certificate
- Pressure Rating Up to 345 bar (5000 psi)
- Stainless Steel Construction
- Economical
- Easy Maintenance Design
FTB-1304 Model Options
View all modelsEdit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.
*Highlighted options are not compatible. Please select a different combination.
Flow Range
Output Signal
Process Connection Size
Category
Media Type
Accuracy
Max Operating Pressure
Max Process Temperature
Wetted Materials
Process Connection Type
Display
- Accuracy Value ±1% reading
- Maximum Operating Pressure 345 bar (5000 psi)
- Maximum Ambient Temperature 85°C (185°F)
- Output Signal 0.5 Hz
- Minimum Ambient Temperature -40°C (-40°F)
- Power Source 8 mA @ 12 Vdc
- Response time 1/F + 25 msec
- Supply Frequency FTB-1300 Models: 0.5 Hz
- Supply Voltage FTB-1300 Models: 10 to 28 Vdc
The FTB-1300 Series of turbine flow meters are designed for industrial and laboratory measurement of water, solvents and other low viscosity fluids. The FTB-1300 Series turbine flow meters feature a 316 stainless steel body and a tungsten carbide bearing. They offer good accuracy and reliability with very little pressure drop. The standard turbine flow meters feature threaded end connections.
The FTB-1300 series of turbine flow meters is designed with a wear resistant rotor assembly to provide trouble free operation and a long service life. Fluid moving through the flow meter causes the rotor to turn at a speed proportional to the flow rate, and as the rotor blades cut through the magnetic field of the pickup, an electronic pulse is generated. The pulse train is used to represent the actual flow or total amount of fluid passing through the flow meter. The number of electronic pulses generated per unit volume is known as a K-factor. The value is constant over each flow meter’s operating range, and is unique to each meter.
SPECIFICATIONS
Pressure Max: 345 bar (5000 psi)
Wetted Materials: Stainless Steel (316L, 303 and 1.4122) and carbide with nickel binder (be sure that the operating fluid is compatible with these materials)
Outputs
Square Wave (FTB-1300 Models):
Supply Voltage: 10 to 28 Vdc
Supply Current: 8 mA @ 12 Vdc, 12 mA @ 24 Vdc
Duty Signal: 50% ±15%
Minimum Signal: 0.5 Hz
Frequency Output: Flow dependent, up to 2000 Hz
Driving Capacity: 50 mA Max resistive load
Output Impedance: ~40?, analog switch and self-resetting fuse
Temperature Range: -40 to 85°C (-40 to 185°F)
Current (FTB-1310 Models):
Supply Voltage: 10 to 30 Vdc
Input: 0.25 Hz to 5 kHz
Update Time: 1/F + 25 msec
Amplitude: 1V p-p to 40V p-p
Linearity: ±0.01% of reading
Output: 4 to 20 mA
Enclosure Certifications: NEC Class I Groups C, D; Class II Groups E, F, G
Temperature Range: -40 to 85°C (-40 to 185°F)
The FTB-1300 series of turbine flow meters is designed with a wear resistant rotor assembly to provide trouble free operation and a long service life. Fluid moving through the flow meter causes the rotor to turn at a speed proportional to the flow rate, and as the rotor blades cut through the magnetic field of the pickup, an electronic pulse is generated. The pulse train is used to represent the actual flow or total amount of fluid passing through the flow meter. The number of electronic pulses generated per unit volume is known as a K-factor. The value is constant over each flow meter’s operating range, and is unique to each meter.
SPECIFICATIONS
Pressure Max: 345 bar (5000 psi)
Wetted Materials: Stainless Steel (316L, 303 and 1.4122) and carbide with nickel binder (be sure that the operating fluid is compatible with these materials)
Outputs
Square Wave (FTB-1300 Models):
Supply Voltage: 10 to 28 Vdc
Supply Current: 8 mA @ 12 Vdc, 12 mA @ 24 Vdc
Duty Signal: 50% ±15%
Minimum Signal: 0.5 Hz
Frequency Output: Flow dependent, up to 2000 Hz
Driving Capacity: 50 mA Max resistive load
Output Impedance: ~40?, analog switch and self-resetting fuse
Temperature Range: -40 to 85°C (-40 to 185°F)
Current (FTB-1310 Models):
Supply Voltage: 10 to 30 Vdc
Input: 0.25 Hz to 5 kHz
Update Time: 1/F + 25 msec
Amplitude: 1V p-p to 40V p-p
Linearity: ±0.01% of reading
Output: 4 to 20 mA
Enclosure Certifications: NEC Class I Groups C, D; Class II Groups E, F, G
Temperature Range: -40 to 85°C (-40 to 185°F)
Model No. | Fittings | Range LPM | Range GPM | Output/Description |
---|---|---|---|---|
FTB-1301 | ½ NPT | 0.3 to 1.5 | 0.08 to 0.4 | Amplified square wave 60 cm (24") cable |
FTB-1302 | ½ NPT | 1.1 to 11 | 0.3 to 3 | |
FTB-1303 | ½ NPT | 3.4 to 34 | 0.9 to 9 | |
FTB-1304 | ½ NPT | 6 to 60 | 1.6 to 16 | |
FTB-1305 | 1 NPT | 6 to 60 | 1.6 to 16 | |
FTB-1306 | 1 NPT | 11 to 121 | 3 to 32 | |
FTB-1307 | 1½ NPT | 19 to 200 | 5 to 53 | |
FTB-1308 | 2 NPT | 49 to 757 | 13 to 200 | |
FTB-1311 | ½ NPT | 0.3 to 1.5 | 0.08 to 0.4 | 4 to 20 mA, industrial head electronics enclosure |
FTB-1312 | ½ NPT | 1.1 to 11 | 0.3 to 3 | |
FTB-1313 | ½ NPT | 3.4 to 34 | 0.9 to 9 | |
FTB-1314 | ½ NPT | 6 to 60 | 1.6 to 16 | |
FTB-1315 | 1 NPT | 6 to 60 | 1.6 to 16 | |
FTB-1316 | 1 NPT | 11 to 121 | 3 to 32 | |
FTB-1317 | 1½ NPT | 19 to 200 | 5 to 53 | |
FTB-1318 | 2 NPT | 49 to 757 | 13 to 200 |