Configurable, High Accuracy Pressure Transducers
0 to 100 psi, Gauge, 4 to 20 mA, 1/4" NPT Male, MIL-26482-I 10-6P, (-49 to 240 °F)
Quantity | Price each |
---|---|
1-4 | $646.36 |
5-9 | $614.04 |
10-24 | $601.11 |
25-49 | $575.26 |
50-99 | $562.33 |
100+ | $549.41 |
Please add to cart to keep it or exit the configuration
- FAST DELIVERY!
- Fast Response Time
- High ±0.08% BSL Accuracy
- High Precision Performance
- 5-Point NIST Traceable Calibration Included with All Models
- All Stainless-Steel Wetted Parts (IP67/IP65 Ratings)
- Advanced Data Logging/Digital Communication (USB/RS485) Functions
- Wide Selection of Analog Output Signals
- Popular Electrical Termination Options
- Diversified Pressure Ranges for All Pressure Types
- Build/Order Custom Transducers Using Configurator
Edit Options
View all modelsNot all combinations are valid. Options compatible with previous selections will be in bold.
*Highlighted options are not compatible. Please select a different combination or click the CONFIGURE button to build your own.
Product Specs
- Accuracy Value 0.03
- Input Resistance 5000 Ω ±20% typical
- Output Resistance 5000 Ω ±20% typical
- Repeatability ±0.08% BSL maximum
- Vibration 5-2000-5 Hz
- Shock 50 g
- Wetted Materials 316L Stainless Steel
- Zero Balance ±0.5% FS typical 1% maximum (1% typical
The Most Popular Ranges and Configurations are Stocked for Immediate Delivery.
OMEGA’S high accuracy PX409 Series Pressure Transducers have a proven record in high-performance commercial and aerospace applications for over 25 years. A full Wheatstone bridge is diffused into a silicon wafer and then micro-machined to exacting standards to produce a silicon sensor that has excellent stability, linearity, repeatability, and excellent long-term stability. At our state-of-the-art facilities, transducers are calibrated using extremely high accuracy equipment, and a 5-point NIST traceable calibration certificate is included with each model. All Stainless Steel wetted parts, welded construction and premium temperature compensation makes transducers suitable for use in tough industrial environments. OMEGA’s free downloadable Software provides advanced data logging capabilities hence add value and flexibility to your transducer performance.
Build/Order/Ship OMEGA’S MM Series Custom Pressure Transducers to meet your pressure sensing requirements: As a lead pressure transducer manufacturer, Omega has developed a new interactive configuration tool that provides a fast and simple way to build custom transducer suitable for application. MM Series custom transducers allow for over 1-million possible combinations of parameters such as pressure type, range, unit, material, output, accuracy, fitting, temperature compensation range, and electrical termination. At the end of the process, the Configurator will provide a part number, price and delivery time for the transducer. For more information about Configurator, Options Selection and FAQs.
SPECIFICATIONS
Specifications/Model | PX409 Series Standard Pressure Transducers | PX409 Series Hermetically Sealed Gauge (Imperial) | PX409 Series High Speed USB Output Transducers (Imperial/Metric) | PX409 Series RS485 Output Transmitters |
Accuracy | ±0.08% | ±0.08% | ±0.08% | ±0.08% |
Pressure Type | Gauge, Absolute | Sealed Gauge | Gauge, Absolute | Gauge, Absolute |
Output | 0 to 10 Vdc | 0 to 10 Vdc | Digital-USB | RS485 |
Electrical Terminations | Cable | Twist-Lock | Cable (Std USB Connector Termination) | M12 Connector |
Operating Temperature Range | -45 to 121 °C (-49 to 250 °F) or | -45 to 121 °C (-49 to 250 °F) or | -40 to 85 °C (-40 to 185 °F) | -40 to 85 °C (-40 to 185 °F) |
Key Features | 300% or 400% Proof Pressure | Hermetically Sealed for the Harsh Environments | 1000 Reading/Second | Up to 640 Readings/Second |
Data Sheets | PX409 Gauge-Absolute-Vac-CG-Barometric Pressure Transducers | PX409 Hermetically Sealed Gauge Pressure Transducers | PX409 High Speed USB Output Pressure Transducers | PX409-RS485 Output Pressure Transmitter |
* Extra High Accuracy (±0.05% or ±0.03%) Models Available
* Visit Accessories section for compatible Accessories
Some of the most Popular Applications of Pressure Transducers include:
I have a PX409-3.5KGUSBH model transducer that currently reads absolute pressure. Can I calibrate the transducer in house to read relative gauge pressure instead?
Hello, we need to measure up to 20 Bar pressure absolute. You offer a 17.5 Bar and 30 Bar option. Would the 17.5 Bar sensor report up to 20 Bar, and without causing damage?
I need to get accuracy and range on this. Can you please help
I'm trying to locate the free software that is advertised for this product, could you please provide the link?
What do you recommend if we exceed the proof pressure of 300%? Is the equipment still good to use? Would you recommend recalibration?
I am trying to locate the system requirements for the software.
Would the 0 to 350 mbar range transducer be accurate enough to read a 1/10 of a mbar? We are mostly interested in looking at absolute pressures ~1/10 to 10 mbar.
How do I install this sensor in a pipe?
Can the PX409 series be used to measure oil pressure? I cannot find any info stating the acceptable mediums.
CE