Maximum ConductivityWater and other conductive liquids/ 20 µS/cm
Maximum Liquid Temperature-10 to 60°C (14 to 140°F) (non-freezing)
Maximum Operating Pressure145 psi at 20°C (68°F) 116 psi at 40°C (104°F) 87 psi at 60°C (140°F)
Minimum Ambient Temperature5 {C} (41 {F})
Response Time<100 ms
Supply Voltage24 Vdc ±15%
OMEGA’s FMG90 Series electro-magnetic flow sensor for conductive liquid media was developed for OEM applications and does not contain any moving parts. FMG90 series is the most economic electromagnetic flowmeter due to the cost optimized plastic construction. Its design is compact and lightweight. Six flow ranges are available. Changes in temperature, density, viscosity, concentration or electrical conductivity of the medium do not affect the output signal. The sensor is intended for continuous measurement of flow rates or for dosing/batching of liquids with a minimum conductivity of 20 ?S/cm.
Specifications Materials: Electrodes and Grounding Rings: Stainless steel 316L Measuring Pipe and Process Connections: PVDF O-Rings: EPDM Housing: ABS Accuracy: 1% of reading Repeatability: 1% Minimum Conductivity of Medium: Water and other conductive liquids/ 20 µS/cm Medium Temperature: -10 to 60°C (14 to 140°F) (non-freezing) Ambient Temperature: 5 to 60°C (41 to 140°F) Maximum Working Pressure: 145 psi at 20°C (68°F) 116 psi at 40°C (104°F) 87 psi at 60°C (140°F) Response Time: <100 ms Indications: Red LED = power, green LED = flow Signal Shape: Square wave frequency, can be connected as PNP or NPN open collector pulse duty ratio 50:50, maximum signal current 25 mA Electrical Data: Supply: 24 Vdc ±15% Consumption: 0.6 W Protection Measures: Short-circuit proof and polarity protection Connection: 4 pin plug connector M12 x 1 Class: NEMA 4 (IP65) (with attached cable socket)