text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

Ceramic Wire Wound Platinum RTD Elements - Class A, Class 1/3B and Class 1/10B

Item# 1PT100KN1510CL1/3

Ceramic Wire Wound Platinum RTD Elements - Class A, Class 1/3B and Class 1/10B Ceramic Wire Wound Platinum RTD Elements - Class A, Class 1/3B and Class 1/10B

These "KN" Series wire wound platinum sensing elements are available in three tolerance classes:


Class A, Temperature Range -100 to 450°C, Tolerance = ± 0.15+(.002 * t) °C
Class 1/3B, Temperature Range -100 to 350°C, Tolerance = ± 0.10+(.0017 * t) °C
Class 1/10B, Temperature Range 0 to 100°C, Tolerance = ± 1/10*( 0.30+(.005 * t)) °C
with t = temperature in °C regardless of sign.

Note: These elements are capable of being exposed to temperatures between -196 and 600°C, however the tolerances apply only within the temperature ranges shown for each class.

These elements are made with wire wound platinum coils, ceramic housings and palladium-gold alloy lead wires. The small size of the sensor body allows for easy installation in protective tubes or custom housings. Applications include a variety of processes and equipment.
1PT100KN1510CL1/3
  • Available in three tolerance classes:
  • Class A (IEC 60751 Class W0.15)

  • Class 1/3B (IEC 60751 Class W0.1)

  • Class 1/10B

  • Note: See applicable temperature range listed for each tolerance class below
  • Temperature Coefficient of Resistance (Alpha): 0.00385Ω/Ω/°C Nominal
  • Available in Single and Dual Element Styles in Some Sizes
  • Operating Temperature Range -196 to 600°C with Tolerances Assured Over the Specified Temperature Range for Each Class
  • Ceramic Body with Palladium-Gold Alloy Lead Wires
  • Suggested Operating Current: 1 milliamp max.
Application
Resistance or Output Type
Temperature Accuracy
Number of Wires
Probe Diameter
Probe Length
Maximum Temperature Measurement
Minimum Temperature Measurement
See All Options
Quantity Price each
1-9 $33.87
10-24 $32.18
25-49 $31.50
50-99 $30.14
100-199 $29.47
200+ $28.79

In stock

Lead Time ( If not in Stock): 4 weeks

Product Specs

These "KN" Series wire wound platinum sensing elements are available in three tolerance classes:


Class A, Temperature Range -100 to 450°C, Tolerance = ± 0.15+(.002 * t) °C
Class 1/3B, Temperature Range -100 to 350°C, Tolerance = ± 0.10+(.0017 * t) °C
Class 1/10B, Temperature Range 0 to 100°C, Tolerance = ± 1/10*( 0.30+(.005 * t)) °C
with t = temperature in °C regardless of sign.

Note: These elements are capable of being exposed to temperatures between -196 and 600°C, however the tolerances apply only within the temperature ranges shown for each class.

These elements are made with wire wound platinum coils, ceramic housings and palladium-gold alloy lead wires. The small size of the sensor body allows for easy installation in protective tubes or custom housings. Applications include a variety of processes and equipment.