text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

Inline RTD Temperature Transmitter for 100Ω PT RTDs

Item# M12TX-PT100

Inline RTD Temperature Transmitter for 100Ω PT RTDs Inline RTD Temperature Transmitter for 100Ω PT RTDs

Description

The M12TX RTD transmitter is easily ranged and programmable by a computer.The configuration kit required forprogramming is M12TX-CONFIG.This unique transmitter is idealfor areas with space limitationswhere traditional headconnections are too large to fit.The M12 thread design offers asecure industrial connection. Theintegrated connection allows thetransmitter to be mounted directlyon to the sensor.

Specifications
Body: Thermoplastic material
Connection:
    M12x1 Male: In accordance to VDE0627 (output connection)
    M12x1 Female: In accordance to VDE0627 (input connection Pt100)
Sensor: RTD Pt100 (alpha symbol 0.00385) 3-wire connection
Range: -50 to 500°C (-58 to 932°F)
Sensor Break Monitoring:
    Selectable: Upscale (>21.0 mA) or downscale (<3.6 mA) action
    Sensor Short-Circuit: Fixed to downscale (<3.6 mA) action
OutputSignal: 4 to 20 mA
Factory Scaling: 4 to 20 mA Output = 0 to 150°C Default Setting
Permissible Load: 700 @ 24Vdc [RLo= (Vsupply-8,5)/0,020]
Response Time (90%): <50 ms
Isolation In-Out: Non-isolated
Power Supply: 8.5 to 32 Vdc (polarity protected)
Environment Conditions
Temperature: -40 to 80°C (-40 to 176°F) (for plastic body)
Relative Humidity: 0 to 100%
EMC: In accordance to EN 61326
Degree of Protection: IP65 and IP67 in accordance to IEC60529
Accuracy
Transmitter: Maximum of ±0,2°C or ±0.2% of span
Sensor: Class A in accordance to IEC751
Temperature Influence [Deviation from 20°C (68°F)]: Maximum of ±0.3°C/25°C (77°F) or ±0.3% of span/25°C (77°F)
Supply Voltage Influence: Negligible
Range Configurations: It is possible set the input temperature range (span) by the M12TX-CONFIG configuration kit (PC with OS Windows® required)
Zero Adjustments: Any value between -50 to 50°C (-58 to 122°F)
Minimum Span: 50°C (122°F) [if the zero value is set between one of these values: -40°C (-40°F), -20°C (-4°F), 0°C (32°F), 20°C (68°F), 40°C (104°F), the minimum span is 20°C (68°F) rather than 50°C (122°F)]
Sensor Error Compensation: Over 2 points (maximum 1% of span)
Factory Setting: 0 to 150°C (32 to 302°F)/sensor break >21 mA (upscale)


*The M12TX-PT100 is compatible with all sensors with a "-2" European wiring option.
For example: PR-26A-3-100-A-1/4-1200-M12-2, the -2 at the end of the part number specifies the wiring.
The PR-22 probes have standard european wiring.



M12TX-PT100
  • Programmable Inline Transmitter for RTDs
  • Water Resistant Molded M12 Connector (IP67)
  • Secure M12 Connection
  • User Programmable Software Available
  • -50 to 500°C (-58 to 932°F) Full Programmable Range
Application
Resistance or Output Type
Temperature Accuracy
Number of Wires
Electrical Connection Type
Maximum Temperature Measurement
Minimum Temperature Measurement
 This item is available for quick shipping
See All Options
Quantity Price each
1-9 $93.22
10-24 $88.56
25-49 $86.69
50-99 $82.97
100-199 $81.10
200+ $79.24

In stock

Lead Time ( If not in Stock): 8 weeks

Product Specs

Description

The M12TX RTD transmitter is easily ranged and programmable by a computer.The configuration kit required forprogramming is M12TX-CONFIG.This unique transmitter is idealfor areas with space limitationswhere traditional headconnections are too large to fit.The M12 thread design offers asecure industrial connection. Theintegrated connection allows thetransmitter to be mounted directlyon to the sensor.

Specifications
Body: Thermoplastic material
Connection:
    M12x1 Male: In accordance to VDE0627 (output connection)
    M12x1 Female: In accordance to VDE0627 (input connection Pt100)
Sensor: RTD Pt100 (alpha symbol 0.00385) 3-wire connection
Range: -50 to 500°C (-58 to 932°F)
Sensor Break Monitoring:
    Selectable: Upscale (>21.0 mA) or downscale (<3.6 mA) action
    Sensor Short-Circuit: Fixed to downscale (<3.6 mA) action
OutputSignal: 4 to 20 mA
Factory Scaling: 4 to 20 mA Output = 0 to 150°C Default Setting
Permissible Load: 700 @ 24Vdc [RLo= (Vsupply-8,5)/0,020]
Response Time (90%): <50 ms
Isolation In-Out: Non-isolated
Power Supply: 8.5 to 32 Vdc (polarity protected)
Environment Conditions
Temperature: -40 to 80°C (-40 to 176°F) (for plastic body)
Relative Humidity: 0 to 100%
EMC: In accordance to EN 61326
Degree of Protection: IP65 and IP67 in accordance to IEC60529
Accuracy
Transmitter: Maximum of ±0,2°C or ±0.2% of span
Sensor: Class A in accordance to IEC751
Temperature Influence [Deviation from 20°C (68°F)]: Maximum of ±0.3°C/25°C (77°F) or ±0.3% of span/25°C (77°F)
Supply Voltage Influence: Negligible
Range Configurations: It is possible set the input temperature range (span) by the M12TX-CONFIG configuration kit (PC with OS Windows® required)
Zero Adjustments: Any value between -50 to 50°C (-58 to 122°F)
Minimum Span: 50°C (122°F) [if the zero value is set between one of these values: -40°C (-40°F), -20°C (-4°F), 0°C (32°F), 20°C (68°F), 40°C (104°F), the minimum span is 20°C (68°F) rather than 50°C (122°F)]
Sensor Error Compensation: Over 2 points (maximum 1% of span)
Factory Setting: 0 to 150°C (32 to 302°F)/sensor break >21 mA (upscale)


*The M12TX-PT100 is compatible with all sensors with a "-2" European wiring option.
For example: PR-26A-3-100-A-1/4-1200-M12-2, the -2 at the end of the part number specifies the wiring.
The PR-22 probes have standard european wiring.