Ambient + 5°C to 400°C Temperature Dry Block Calibrator
Portable Dry Block Calibrator
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-4 | $4,000.00 |
5-9 | $3,800.00 |
10-24 | $3,720.00 |
25-49 | $3,560.00 |
50-99 | $3,480.00 |
100+ | $3,400.00 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
- 10 Insert Formats Available
- One Multi-Well Insert Included (1/8, 3/16, 1/4, 5/16, 3/8")
- Maximum Operating Temperature of 400°C (752°F)
- Independent Over- Temperature Cutout
- Temperature Sensor Burnout Protection
- NIST-Traceable Calibration Certificate
- Shoulder Carrying Strap, Mains Cable and Insert Removal Tool
CL-355A-230 Model Options
View all modelsEdit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.
*Highlighted options are not compatible. Please select a different combination.
Supply Voltage
Process Temperature Unit
Process Temperature Min
Process Temperature Max
Process Temperature Range
Accuracy Value
Stability
Style
Communications Protocol
Additional Features
The CL-355A is a small, lightweight, portable dry block calibrator, that offers fast heat-up and cooldown times with excellent performance specifications at a wide operating temperature range. It’s a good choice for standard bench lab work or as a portable field unit. The unit covers the temperature range from 5°C (9ºF) above ambient up to 400°C (752ºF) using a large multi-well machined aluminum insert block as the heat transfer medium to the sensors under test. The CL-355A uses the same aluminum inserts as the CL-740A calibrator. This calibrator is designed to work safely under the following conditions: ambient temperature range: 5 to 40°C (9 to 104°F), up to 95% relative humidity, non-condensing.
SPECIFICATIONS
Minimum Temperature: 5°C (9°F) above ambient
Maximum Temperature: 400°C (752°F)
Cooling Rate,400 to 100°C(752 to 212ºF): 21 min
Heating Rate, 20 to 400°C(68 to 752ºF): 12 min
Independent Over-Temperature Cutout: 450°C (842ºF) approx.
Fan Cooling: Automatic
Display Resolution: 0.1°
Weight: 4 kg (9 lb)
Insert Immersion Depth: 4.5
Dimensions: 222.25 H x 203.2 W x 203.2 D mm(8.8 x 7.9 x 7.9")
Stability After 15 Min:: ±0.15°C (±0.27ºF)
Display Accuracy: : ±0.6°C (±1.1ºF)
Well to Well Uniformity: 0.015 to 0.025°C(32.02 to 32.04ºF)
SPECIFICATIONS
Minimum Temperature: 5°C (9°F) above ambient
Maximum Temperature: 400°C (752°F)
Cooling Rate,400 to 100°C(752 to 212ºF): 21 min
Heating Rate, 20 to 400°C(68 to 752ºF): 12 min
Independent Over-Temperature Cutout: 450°C (842ºF) approx.
Fan Cooling: Automatic
Display Resolution: 0.1°
Weight: 4 kg (9 lb)
Insert Immersion Depth: 4.5
Dimensions: 222.25 H x 203.2 W x 203.2 D mm(8.8 x 7.9 x 7.9")
Stability After 15 Min:: ±0.15°C (±0.27ºF)
Display Accuracy: : ±0.6°C (±1.1ºF)
Well to Well Uniformity: 0.015 to 0.025°C(32.02 to 32.04ºF)


CE Approved

Alarm light is illuminated and I cannot get it to turn off. How can I fix this?
Thank you for your inquiry. Please contact our Temperature Department for tech support, or send email to temp@omega.com
Date published: 2020-08-07
Accessories