  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • Models Available for Thermocouples, RTD’s, DC Voltage and Current Inputs
  • Isolated and Linearized
  • 24 Vdc Power
  • 0 to 10 V or 4 to 20 mA Outputs
  • Slim Housing Mounts on DIN Rail

Edit Options

View all models

Not all combinations are valid. Options compatible with previous selections will be in bold.

*Highlighted options are not compatible. Please select a different combination.

Input Type
Input Class
Input Ranges
Output Type
Output Class
Supply Voltage Type
Isolation
Programability


Product Specs

  • Accuracy Value ±0.1% of fs
  • Form Factor DIN Rail
  • Maximum Ambient Temperature 55 {C} (131 {F})
  • Minimum Ambient Temperature 0 {C} (32 {F})
  • Maximum Storage Temperature 80 {C} (176 {F})
  • Minimum Storage Temperature -40 {C} (-40 {F})
  • RTD Connection 2-Wire or 3-Wire
  • RTD Curves Supported alpha = 0.00385
  • Form Factor DIN Rail
  • Accuracy Value ±0.1% of fs
  • Maximum Storage Temperature 80 {C} (176 {F})
  • Maximum Ambient Temperature 55 {C} (131 {F})
  • Minimum Ambient Temperature 0 {C} (32 {F})
  • Minimum Storage Temperature -40 {C} (-40 {F})
  • RTD Connection 2-Wire or 3-Wire
  • RTD Curves Supported alpha = 0.00385

The DRC-8900 Series DIN rail mount signal conditioners are ideal for a wide range of process monitoring applications. Models are available for a many different input types including thermocouples, RTDs, and process voltage or current. All models isolate and linearize. The thermocouple input models also have cold junction compensation. These signal conditioners have three way isolation … input to output, input to power and output to power. All models are powered by 24 Vdc and are housed in a plastic case with a built-in DIN rail mounting foot. Connections are made to easily accessible screw terminals.

  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getReviews, 0ms
  • REVIEWS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 1ms
  • QUESTIONS, PRODUCT
  • bvseo-msg: The resource to the URL or file is currently unavailable.;
Accessories
35 mm (1.4") DIN rail, 1 m (3.3') length
$11.40
30 In Stock
2m (6.5') section 35 mm DIN rail
$21.51
15 In Stock

en-US
en
Save Configuration