PST joins DwyerOmega. Read more>
The Cutler-Hammer® iProx Series senses up to three times further than typical sensors in its class. The ideal choice for the most demanding inductive sensing applications.
Product Number | Sensor Type | Sensing Range | Supply Voltage | Shielding | Connection Type | Diameter |
---|---|---|---|---|---|---|
|
2-Wire, N.O. Output
|
4 mm
|
20 to 132 Vac
|
Shielded
|
2 m Cable
|
12 mm
|
|
3-Wire, N.O. Output
|
4 mm
|
6 to 48 Vdc
|
Shielded
|
2 m Cable
|
12 mm
|
|
2-Wire, N.O. Output
|
10 mm
|
20 to 132 Vac
|
Unshielded
|
2 m Cable
|
12 mm
|
|
3-Wire, N.O. Output
|
10 mm
|
6 to 48 Vdc
|
Unshielded
|
2 m Cable
|
12 mm
|
|
3-Wire, N.O. Output
|
8 mm
|
6 to 48 Vdc
|
Shielded
|
2 m Cable
|
18 mm
|
Cutler-Hammer® E58 Series can withstand the harshest physical, chemical and optical environments. Built to withstand heavy shock and vibration in almost any application.
Product Number | Sensor Type | Sensing Range | Supply Voltage | Connection Type | Field of View | Diameter | Features |
---|---|---|---|---|---|---|---|
|
3-, 4-Wire, N.O. Output, Light/Dark Operate
|
250 m
|
20 to 132 Vac, 15 to 30 Vdc
|
2 m Cable
|
830 mm Dia @ 7.6m
|
30 mm
|
Source Thru-Beam
|
|
3-, 4-Wire, N.O. Output, Dark Operate
|
10 m
|
20 to 132 Vac, 15 to 30 Vdc
|
2 m Cable
|
150 mm Dia @ 6 m
|
30 mm
|
Polarized Reflex
|
|
2-Wire, N.O. Output, Light Operate
|
100 mm
|
90 to 132 Vac, 18 to 50 Vdc
|
2 m Cable
|
10 mm Dia @ 100 mm
|
18 mm
|
Perfect Prox
|
|
3-, 4-Wire, N.O. Output, Dark Operate
|
250 m
|
20 to 132 Vac, 15 to 30 Vdc
|
2 m Cable
|
830 mm Dia @ 7.6m
|
30 mm
|
Detector Thru-Beam
|
|
2-Wire, N.O. Output, Light Operate
|
280 mm
|
90 to 132 Vac, 18 to 50 Vdc
|
2 m Cable
|
26 mm Dia @ 280 mm
|
30 mm
|
Perfect Prox
|
The Cutler-Hammer® Premium+ Series inductive proximity sensors feature a rugged stainless steel body, shock resistant front caps and impact absorbing potting compound.
Product Number | Sensor Type | Sensing Range | Supply Voltage | Shielding | Connection Type | Diameter |
---|---|---|---|---|---|---|
|
2-Wire, N.O. Output
|
2 mm
|
24 to 240 Vac, 20 to 240 Vdc
|
Shielded
|
2 m Cable
|
12 mm
|
|
2-Wire, N.O. Output
|
5 mm
|
24 to 240 Vac, 20 to 240 Vdc
|
Shielded
|
2 m Cable
|
18 mm
|
|
2-Wire, N.O. Output
|
10 mm
|
24 to 240 Vac, 20 to 240 Vdc
|
Shielded
|
2 m Cable
|
30 mm
|
|
2-Wire, N.O. Output
|
4 mm
|
24 to 240 Vac, 20 to 240 Vdc
|
Unshielded
|
2 m Cable
|
12 mm
|
|
2-Wire, N.O. Output
|
8 mm
|
24 to 240 Vac, 20 to 240 Vdc
|
Unshielded
|
2 m Cable
|
18 mm
|
These unique Cutler-Hammer® Inductive Proximity Sensors are designed to be used in extremely small spaces. Available in housing diameters of 8 mm (0.31') and 5 mm (0.20').
Product Number | Sensor Type | Sensing Range | Supply Voltage | Shielding | Connection Type | Diameter |
---|---|---|---|---|---|---|
|
3-Wire, N.O. Output, NPN
|
3 mm
|
10 to 30 Vdc
|
Shielded
|
2 m Cable
|
8 mm
|
|
3-Wire, N.O. Output, PNP
|
3 mm
|
10 to 30 Vdc
|
Shielded
|
2 m Cable
|
8 mm
|
|
3-Wire, N.O. Output, NPN
|
1 mm
|
10 to 30 Vdc
|
Shielded
|
2 m Cable
|
8 mm
|
|
3-Wire, N.O. Output, PNP
|
1 mm
|
10 to 30 Vdc
|
Shielded
|
2 m Cable
|
8 mm
|
|
3-Wire, N.O. Output, NPN
|
2 mm
|
10 to 30 Vdc
|
Shielded
|
2 m Cable
|
8 mm
|
The Series DT Detector Position Sensors are reliable, magnetically actuated, SS, completely interchangeable with competitive units. AC or DC for user friendly operation. They have no moving parts, eliminate costly seal fittings and offer enhanced reliability by eliminating arcing.
Product Number | Media Type | Measurement Type | Switch Type | Electrical Rating | Temperature Limits | Sensing Distance | Response Time | Repeatability | Hysteresis | Electrical Connection | Enclosure Rating | Agency Approvals |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Position monitoring & indication
|
Magnetic Point Sensor
|
Tungsten, SDPT, form C
|
3A @ 125 VAC, 3A @ 30 VDC
|
-40 to 163F (-40 to 73C)
|
0.1" Sensing Distance
|
3.0 ms
|
0.005" (.01 cm)
|
0.030" (.08 cm)
|
Factory sealed leads, 18" min, 4 Conductor, PVC insulated 18 AWG
|
Weatherproof and explosion proof
|
CSA, cULus
|
|
Position monitoring & indication
|
Magnetic Point Sensor
|
Tungsten, SDPT, form C
|
3A @ 125 VAC, 3A @ 30 VDC
|
-40 to 163F (-40 to 73C)
|
0.5" Sensing Distance
|
3.0 ms
|
0.005" (.01 cm)
|
0.030" (.08 cm)
|
Factory sealed leads, 18" min, 4 Conductor, PVC insulated 18 AWG
|
Weatherproof and explosion proof
|
CSA, cULus
|