LVIT Linear Position Sensors
0 to 100 mm, 0 to 10 Vdc output Output
Volume discounts available
Volume Discount Schedule
Quantity | Price each |
---|---|
1-4 | $499.57 |
5-9 | $474.59 |
10-24 | $464.60 |
25-49 | $444.62 |
50-99 | $434.63 |
100+ | $424.63 |
Added to Your Shopping Cart
Configuration complete.
Please add to cart to keep it or exit the configuration
Please add to cart to keep it or exit the configuration
Failed to Save Configurations, Click on Configure Button Start Again
- Excellent stroke-to-length ratio
- Rugged 19 mm (0.75") Diameter stainless steel housing
- Field adjustable range scaling
- Wide Choice of Range: 15 to 750 mm (⅝” to 30") Full Scale
- Designed to Operate Under Adverse Temperature, Vibration, Shock, and Humidity Conditions
- Applications
- PV Solar Cell Positioner
- Wind Energy Systems
- Packaging Machinery
- Motorsport Vehicles
- Automotive Testing
- Factory Automation
- OEM Test Stands
LDI-619-100-A010S Model Options
View all modelsEdit these specs to order a different model. Not all combinations are valid. Options compatible with previous selections will be in bold.
*Highlighted options are not compatible. Please select a different combination.
Range
Electrical Output
Housing Length
Linearity
Resolution
Rating
Housing Diameter/Width
Features
The LDI-619 Series LVIT (Linear Variable Inductive Transducer) position sensors from OmegaTM are devices designed for factory automation and a variety of industrial and commercial applications such as motor sport vehicles, automotive testing, solar cell positioners, wind turbine prop pitch and brakes, and packing equipment. With their compact device, rugged stainless-steel construction, superior performance, and excellent stroke-to-length ratio, the LDI-619 sensors are ideal for both industrial testing, laboratories, and OEM applications.
LDI-619 sensors are offered in 15 full scale ranges from 15 to 900 mm (⅝ to 36"). Calibration and set-up is simplified with one wire field programming feature, this provides the ability to match the end points of the sensor's analog output with the ends of the range of motion of the assembly to which the sensor is attached. This feature permits a user to optimize the position measuring system's resolution over its full range of motion.
LDI-619 products come with axil exiting cable & a M5 x 0.8 threaded end for installation.
Specifications
Analog I/Os:
0 to 10V output with 12 to 30V input, 35 mA max;
4 to 20 mA (3-wire) output with 18 to 30V input, 60 mA max 75°C (167°F max)
Measuring Range: 2.5 to 900 mm (⅝” to 36") Full Scale
Linearity Error: ±0.15% of Full Scale Output (FSO) typical, ±0.25% max
Resolution: 0.025% of FS
Update Rate: 300 Hz nominal
Operating Temperature: -20 to 85°C (-4 to 185°F)
Temperature Coefficient: 0.015% of FS/°C
Vibration: 5 to 20 Hz, 0.5" p-p; 20 to 2000 Hz, 4.2 g p-p
Shock: 1000 g, 11 ms
Terminations: IEC IP67
Humidity: 95% RH, non-condensing
Housing Material: Stainless steel
LDI-619 sensors are offered in 15 full scale ranges from 15 to 900 mm (⅝ to 36"). Calibration and set-up is simplified with one wire field programming feature, this provides the ability to match the end points of the sensor's analog output with the ends of the range of motion of the assembly to which the sensor is attached. This feature permits a user to optimize the position measuring system's resolution over its full range of motion.
LDI-619 products come with axil exiting cable & a M5 x 0.8 threaded end for installation.
Specifications
Analog I/Os:
0 to 10V output with 12 to 30V input, 35 mA max;
4 to 20 mA (3-wire) output with 18 to 30V input, 60 mA max 75°C (167°F max)
Measuring Range: 2.5 to 900 mm (⅝” to 36") Full Scale
Linearity Error: ±0.15% of Full Scale Output (FSO) typical, ±0.25% max
Resolution: 0.025% of FS
Update Rate: 300 Hz nominal
Operating Temperature: -20 to 85°C (-4 to 185°F)
Temperature Coefficient: 0.015% of FS/°C
Vibration: 5 to 20 Hz, 0.5" p-p; 20 to 2000 Hz, 4.2 g p-p
Shock: 1000 g, 11 ms
Terminations: IEC IP67
Humidity: 95% RH, non-condensing
Housing Material: Stainless steel
Wiring Table | |
---|---|
I/O Function | Color |
+Power Input | Red |
Ground | Black |
Analog output | Green |
Field Programming | White |
Shield/ drain* | Shield |
*Shield unconnected internally |

LDI-619 Range Table | ||
---|---|---|
Nominal Range | Length “A” | |
Inches | mm | mm (Inches) |
≤1 | ≤25 | 35.0 (1.38) |
1.2 | 30 | 41.3 (1.63) |
2 | 50 | 60.5 (2.38) |
3 | 75 | 85.9 (3.38) |
4 | 100 | 111.1 (4.38) |
6 | 150 | 165.1 (6.5) |
8 | 200 | 215.9 (8.50) |
10 | 250 | 266.7 (10.50) |
12 | 300 | 317.5 (12.50) |
15 | 375 | 400.0 (15.75) |
18 | 450 | 476.2 (18.75) |
24 | 600 | 635.0 (25.00) |
30 | 750 | 787.4 (31.00) |