Loop Powered Ultrasonic Level Transmitter
Non-Contact Loop Powered Ultrasonic Level Transmitter
Quantity | Price each |
---|---|
1-4 | $780.65 |
5-9 | $741.62 |
10-24 | $726.00 |
25-49 | $694.78 |
50-99 | $679.17 |
100+ | $663.55 |
Please add to cart to keep it or exit the configuration
- Simple, Fast Setup with Pushbutton Calibration and LCD Display
- Four Measurement Ranges Available up to 10 m (32')
- 6-segment LCD Display Indicates Air Gap or Liquid Level (Inch or Centimeter Units)
- 5 cm (2") Minimum Beam Width for Applications with Restricted Space
- NEMA 4X (IP65) Enclosure with Rugged PVDF Transducer
- Fail-Safe Intelligence with Diagnostic Feedback for Easy Troubleshooting
Edit Options
View all modelsNot all combinations are valid. Options compatible with previous selections will be in bold.
*Highlighted options are not compatible. Please select a different combination.
Product Specs
The LVU800 Series general purpose 2-wire ultrasonic transmitter provides non-contact level measurement up to 10 m (32'), and is ideally suited for challenging ultrapure, corrosive or waste liquids. Pushbutton calibrated, the transmitter is broadly selected for atmospheric bulk storage, day tank and waste sump applications. Media examples include wastewater and sodium hydroxide.
SPECIFICATIONS
Range:
LVU809: 10 cm to 3 m (4" to 9.8')
LVU816: 20 cm to 5.5 m(8" to 18')
LVU826: 20 cm to 8 m(8" to 26.2')
LVU832: 30 cm to 10 m(12" to 32.8')
Accuracy: ±0.2% of span
Resolution:
LVU809: 0.5 mm (0.019")
LVU816/826: 1 mm (0.039")
LVU832: 2 mm (0.078")
Beam Width:
LVU809: 5 cm (2") dia.
LVU816/LVU826/LVU832: 7.6 cm (3") dia.
Deadband:
LVU809: 10 cm (4")
LVU816: 20 cm (8")
LVU826: 20 cm (8")
LVU832: 30 cm (12")
Display Type: LCD, 6-digit
Display Units: Inch, cm or percent
Display Mode: Air gap or liquid height
Memory: Non-volatile
Supply Voltage: 12 to 28 Vdc
Loop Resistance: 500 O @ 24 Vdc
Signal Output: 4 to 20 mA, 2-wire
Signal Invert: 4 to 20 mA or 20 to 4 mA
Calibration: Push button
Fail-Safety: Selectable 4 mA, 20 mA, 21 mA, 22 mA or hold
Process Temperature: -20 to 60°C (-7 to 140°F)
Temperature Compensation: Automatic
Electronics Temperature:n -40 to 71°C (-40 to 160°F)
Pressure: 30 psi (2 bar) @ 25°C, derated @ 1.667 psi (0.113 bar) per above 25°C
Enclosure Rating: NEMA 4X (IP65)
Enclosure Vent: Watertight membrane
Enclosure Material: PC/ABS FR
Transducer Material: PVDF
Process Mount:
LVU809: 1 NPT or 1"G
LVU816/LVU826/LVU832: 2 NPT or 2" G
Mounting Gasket: FKM
Conduit Entrance: Dual, 1/2 NPT
Classification: General purpose CE compliance EN 61326 EMC
you · a few seconds ago we want to purchase level transmitter for use on caustic closed tank and HNO3 Closed tanks. please suggest us the model which is compatible to these liquids. range of tanks are upto 5meters.
CE