text.skipToContent text.skipToNavigation

If you have previously used the Omega Website, you will need to Reset your Password on the new site.
Resetting your password is required one time only.

Configure Product
Saved Configuration
View Configuration
Terms and Conditions
Saved Addresses
Your card information was not accepted. Please contact the issuing bank for details.
Payment submission timed out. The server might be busy.
There was an error processing your request.
Please verify there are no missing or invalid fields.
Please enter a card number
Please select a card type
Please enter a value for this field
Please enter an expiry month
Please enter an expiry year
Please enter an issue number
Please enter a start month
Please enter a start year
The card number is not valid
The card type is not supported
The card verification code is not valid
The expiry month is not valid
The expiry year is not valid
The issue number is not valid
The start month is not valid
The start year is not valid
This field is required
Errors were found with the address you provided. Please verify your address.
Date should be in MM/DD/YYYY format
Please enter valid values
Please enter future date
Please enter the shipping date
Shipment date is updated

General Purpose RTD (PT100) Probes with No Transition Junction Between Leads and Sheath

Item# PR-10-1-100-1/4-15-E-SB

General Purpose RTD (PT100) Probes with No Transition Junction Between Leads and Sheath General Purpose RTD (PT100) Probes with No Transition Junction Between Leads and Sheath

This general purpose RTD probe transitions directly to 36" lead wires without the use of a metal transition fitting. This design makes for a more compact probe when space limitations are a factor. Note that the point where the lead wire exits the probe sheath will not be as durable as on the PR-11 probe, which uses the metal transition and spring as strain relief.


 
PR-10-1-100-1/4-15-E-SB
  • Temperature Range -200 to 600°C
  • Three Lead Configuration Standard
  • Two Black Leads Connected to Same Side of RTD Element
  • Leads Terminate with 3 Stripped Wires
  • Alpha = .00385 Standard
  • Accuracy: Class A Per IEC 60751
  • 6, 12, 18, and 24 inch Probe Lengths Standard
  • Ro = 100Ω @ 0°C

Application
Resistance or Output Type
Temperature Accuracy
Number of Wire
Probe Diameter
Probe Length
Mounting Style
Electrical Connection Type
Maximum Temperature Measurement
Minimum Temperature Measurement
Cable Length
Additional Features
See All Options
Quantity Price each
1-9 $88.58
10-24 $84.15
25-99 $79.72
100-499 $75.29
500-999 $70.86
1000+ $66.44

In stock

Lead Time ( If not in Stock): 3 weeks

Product Specs

  • Measurement Type Temperture
  • Probe Material Stainless Steel

This general purpose RTD probe transitions directly to 36" lead wires without the use of a metal transition fitting. This design makes for a more compact probe when space limitations are a factor. Note that the point where the lead wire exits the probe sheath will not be as durable as on the PR-11 probe, which uses the metal transition and spring as strain relief.


 

en-US
en
Save Configuration