text.skipToContent text.skipToNavigation

Low Cost SS Compact Pressure Transmitter

$99.00

Item# PX119-3KGI

 This item is available for quick shipping
Volume discounts available
Volume Discount Schedule
Quantity Price each
1-4 $99.00
5-9 $94.05
10-24 $92.07
25-49 $88.11
50-99 $86.13
100+ $84.15

In stock

Lead Time ( If not in Stock): 4 weeks

Low Cost SS Compact Pressure Transmitter PX119-3KGI PX119-3KGI
Low Cost SS Compact Pressure Transmitter is rated 4.4 out of 5 by 5.
  • y_2020, m_7, d_9, h_15
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.10
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_5
  • loc_en_US, sid_PX119-3KGI, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getAggregateRating, 1ms
  • REVIEWS, PRODUCT
  • Designed to integrate with a variety of industrial and OEM applications with its compact, rugged, and SS body
  • Piezo-resistive ceramic diaphragm provides premium thermal compensation for minimal thermal drift
  • Comes with 20mm Mating DIN Connector
  • Perfect for applications where a 0.5% accuracy is desired
  • No minimum purchase required

Edit Options

View all models

Not all combinations are valid. Options compatible with previous selections will be in bold.

*Highlighted options are not compatible. Please select a different combination.

Pressure Range
Pressure Type
Accuracy Class
Accuracy Value (compensated range)
Output Signal
Electrical Output
Pressure Port Size
Pressure Port Type
Connection/Termination
Operating Temperature Range


Product Specs

  • Accuracy Value 0.50% BFSL Accuracy
  • Maximum Compensation Temperature 0°C (32°F)
  • Minimum Compensation Temperature 0°C (32°F)
  • Vibration 10 g (20 to 2000 Hz) for <58 psi (4 bar)
  • Wetted Materials 304 SS and Ceramic Al2O3

Description

Pressure Without the Pain

Ideally suited for material handling, industrial and mobile equipment applications where a small, yet rugged SS body size is desired at a reasonable price point. The body is machined from a single piece of stainless steel to provide added protection for the internal electronics as well as prevent corrosion from most applications. A piezoresistive ceramic sensor along with ASIC signal conditioning provides an excellent thermally compensated output.
PX119 Low Cost SS Compact Pressure Transmitter
  • SIMPLE
  • MULTIPURPOSE
  • COMPACT
Monitor air brake pressureMonitor air brake pressure
Monitor pressure/height in vehicle suspension
Regulate pneumatic door operation
Monitor excessive load
Monitor lift operation
Monitor compact pressure
Monitor lift operation
  • Great cost: performance ratio
    Accuracy: 0.5% BFSL
  • Large pressure range
    15 to 5000 psi (absolute or gauge)
  • Piezoresistive ceramic diaphragm
    Excellent thermally compensated output
    Operating temp: -40 to 135°C (32 to 185°F)
  • Reliable output with signal conditioning
    Output: 4 to 20 mA / Input: 8 to 30 Vdc
    Response time: 1 ms
  • Rugged form factor
    Shock and vibration resistant
    10g for <58 psi/20g for >58 psi
  • Resists corrosion and water
    304 SS body
    Wetted materials: Ceramic AI2O3, NBR

Rated 4 out of 5 by from Awesome I needed a pressure transmitter and looked everywhere. I found very cheap to very expensive and long ship times. I ordered the Omega. I got it in 2 days and it has worked very well
Date published: 2018-05-14
Rated 4 out of 5 by from Easy to Install and Use We purchased several of these in three different ranges. The first item is the ease of wiring the connector. Previous transducers used required soldering the wires to the connector terminals. There units have a simple screw lug that you simply insert the lead and screw tight in place. The time involved was less than half to complete connections. The transducers themselves work very well. My only minor concern is that the terminals on the transducer are exposed and can be bent easily. However, since there should be minimal need to remove the transducer connector, this is not a big concern.
Date published: 2019-03-06
Rated 5 out of 5 by from Pressure Transmitter This is a rugged little piece of equipment. I'ts accurate enough for what I'm doing, has held up to sub-optimal conditions and the price is unbeatable.
Date published: 2019-02-05
Rated 5 out of 5 by from Great, simple transmitter Great pressure transmitter for the price, included DIN connector makes wiring very straightforward. Has a good resolution and is very compact.
Date published: 2020-04-02
Rated 4 out of 5 by from good value for money: they are good, practical and low cost
Date published: 2018-08-08
  • y_2020, m_7, d_9, h_15
  • bvseo_bulk, prod_bvrr, vn_bulk_3.0.10
  • cp_1, bvpage1
  • co_hasreviews, tv_0, tr_5
  • loc_en_US, sid_PX119-3KGI, prod, sort_[SortEntry(order=HELPFULNESS, direction=DESCENDING), SortEntry(order=POSITIVE_FEEDBACK, direction=DESCENDING), SortEntry(order=SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getReviews, 0ms
  • REVIEWS, PRODUCT

Can NIST traceable calibration documentation be shipped with this product?

Asked by: jon582
Thank you for your inquiry? This part doesn't come with a cert. We do have many other like the px309 series and px409 series that do. hope this was helpful?
Answered by: application engineer je
Date published: 2020-02-12

Are these National Sanitation Foundation (NSF) certified?

Asked by: clau
NIST certification cannot be supplied with this unit.
Answered by: JKengineer
Date published: 2019-12-31

I am using this pressure transducer in conjunction with water, can water flow into the mini DIN connector ? If not, how can I prevent water from flowing into this space and get a pressure reading?

Asked by: Anonymous
Unfortunately, the unit PX119 is not a waterproof unit so the application that you have mentioned (water flowing into the connector) will not work. We do sell submersible units that are great for that application like the PX709 series. All those would be a bigger investment. You could try and RTV the entire PX119 to see of you would give you a waterproof seal? The main issue is trying to keep an electrical connection dry! Thanks for connecting with us, let us know if you have any further questions.
Answered by: Jane
Date published: 2019-05-15

Can this be use for oil?

Asked by: SamIe
The wetted parts for the PX119 are 316 SS, ceramic, and Nitrile rubber (NBR). The wetted parts are the surfaces that will come in contact with the process fluid. While we cannot speak for all oils or fuels. The wetted materials of the PX119 are generally resistant to oil, fuel, and other chemicals. We recommend that users investigate material compatibility for their specific application if they have any concerns.
Answered by: Jane
Date published: 2019-05-02

Can the 1/4 NPT male port be connected into a tee fitting, to which it would measure the pressure of water directly? The rest of the transducer would not be exposed to water or submerged in water, but water will be free to flow into the male port.

Asked by: Reynaldo
Thank you for reaching out to us with your question. Yes, it can. The wetted parts are Ceramic, NBR 304 SS - all are compatible with water.
Answered by: Jane
Date published: 2019-02-22

How is the zero/span adjusted for this transducer?

Asked by: Jimbo C
Thank you for contacting Omega. This transducer does not have any capability to adjust the outputs. The PX509 or PX51 are products that offer trim pots to make these sort of adjustments. Please contact our Tech Support if you need any further assistance. https://www.omega.com/pptst/px51-pxm51-series.html
Answered by: Jane
Date published: 2019-02-19

Would a sensor like this make sense to use to measure vacuum ?

Asked by: Dave B
Hi, thanks for your question. We do not offer PX119 that measures gauge pressures less than zero. I would recommend the PX309, we have vacuum ranges available.
Answered by: Jane
Date published: 2019-01-17

What is the maximum pressure that the PX119-600AI can withstand without damage to the transducer?

Asked by: Djmyersn
Hello, this data can be found on the product spec sheet. Please note, to understand the table there are 2 values overload and burst. Proof is the safe pressure limit for when below the sensors output will not permanently change. Burst is the safe pressure limit, above which the sensor may break-open under pressure. For the PX119-600AI: Proof is 241.7% so 600*2.417= 1450 psi Burst is 2901% so 600*2.417= 1740 psi
Answered by: Jane
Date published: 2019-04-24
  • y_2020, m_7, d_9, h_15CST
  • bvseo_bulk, prod_bvqa, vn_bulk_3.0.10
  • cp_1, bvpage1
  • co_hasquestionsanswers, tq_25
  • loc_en_US, sid_PX119-3KGI, prod, sort_[SortEntry(order=LAST_APPROVED_ANSWER_SUBMISSION_TIME, direction=DESCENDING)]
  • clientName_omega
  • bvseo_sdk, java_sdk, bvseo-4.0.0
  • LOCAL, getContent, 10ms
  • QUESTIONS, PRODUCT

en-US
en
Save Configuration