Call us at 1-888-826-6342
The PX831 series is ATEX, UL, FM, and CSA approved for hazardous locations, particularly oil, gas, and alternative energy applications. Available in ranges from 5 to 7,500 psi
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 5000 psi
|
Gauge
|
> 0.25%
|
±0.4%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable with Conduit
|
-40 to 120 °C (-40 to 248 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Gauge
|
> 0.25%
|
±0.4%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable with Conduit
|
-40 to 120 °C (-40 to 248 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Gauge
|
> 0.25%
|
±0.4%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable with Conduit
|
-40 to 120 °C (-40 to 248 °F)
|
Not Applicable
|
|
0 to 3,000 psi
|
Gauge
|
> 0.25%
|
±0.4%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable with Conduit
|
-40 to 120 °C (-40 to 248 °F)
|
Not Applicable
|
|
0 to 5 psi
|
Gauge
|
> 0.25%
|
±0.4%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable with Conduit
|
-40 to 120 °C (-40 to 248 °F)
|
Not Applicable
|
The PX3005 series are rangeable, with a backlit LCD display, ideal for monitoring pressures in process automation, hydraulic systems, pumps and tank level applications.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 30 psi
|
Absolute
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
-1 to 1 psi
|
Compound Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
-3 to 3 psi
|
Compound Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
0 to 5 psi
|
Absolute
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
-5 to 5 psi
|
Compound Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
The PX2300 series are ideal for measuring pressure drop across filters and/or in corrosive media, with a weatherproof, NEMA 4 enclosure and high ±0.25% accuracy.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 2 psi
|
Differential
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-18 to 80 °C (0 to 176 °F)
|
Not Applicable
|
|
0 to 1 psi
|
Differential
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-18 to 80 °C (0 to 176 °F)
|
Not Applicable
|
|
0 to 5 psi
|
Differential
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-18 to 80 °C (0 to 176 °F)
|
Not Applicable
|
|
0 to 10 psi
|
Differential
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-18 to 80 °C (0 to 176 °F)
|
Not Applicable
|
|
-1 to 1 psi
|
Differential
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-18 to 80 °C (0 to 176 °F)
|
Not Applicable
|
The PX3005-DIFF differential series are rangeable, with a backlit LCD display, ideal for monitoring pressures in process automation, hydraulic, and tank level applications.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
-70 to 150 psi
|
Differential
|
< 0.1%
|
±0.075%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
-1,000 to 1,000 inH2O
|
Differential
|
< 0.1%
|
±0.075%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
-25 to 25 inH2O
|
Differential
|
< 0.1%
|
±0.075%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
-70 to 400 psi
|
Differential
|
< 0.1%
|
±0.075%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
|
-70 to 1,500 psi
|
Differential
|
< 0.1%
|
±0.075%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
M12
|
-20 to 70 °C (-4 to 160 °F)
|
Rangable with 5 digit display
|
Product Number | Pressure Range | Pressure Type | Accuracy Class | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Accuracy Value |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 10 inH2O
|
Differential
|
> 0.25%
|
Current
|
4 to 20 mA
|
1/8"
|
Barbed Fitting
|
Terminal Block
|
-17.8 to 60°C (0 to 140°F)
|
±2%
|
|
0 to 1 inH2O
|
Differential
|
> 0.25%
|
Current
|
4 to 20 mA
|
1/8"
|
Barbed Fitting
|
Terminal Block
|
-17.8 to 60°C (0 to 140°F)
|
±2%
|
|
0 to 2 inH2O
|
Differential
|
> 0.25%
|
Current
|
4 to 20 mA
|
1/8"
|
Barbed Fitting
|
Terminal Block
|
-17.8 to 60°C (0 to 140°F)
|
±2%
|
|
0 to 3 inH2O
|
Differential
|
> 0.25%
|
Current
|
4 to 20 mA
|
1/8"
|
Barbed Fitting
|
Terminal Block
|
-17.8 to 60°C (0 to 140°F)
|
±2%
|
|
0 to 5 inH2O
|
Differential
|
> 0.25%
|
Current
|
4 to 20 mA
|
1/8"
|
Barbed Fitting
|
Terminal Block
|
-17.8 to 60°C (0 to 140°F)
|
±2%
|
The PX509-IS series is FM approved, shock and vibration rated, with a ±0.08% accuracy, ideal for hazardous locations. Available in ranges from 10 inH2O to 5,000 psi.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 500 psi
|
Absolute
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
M12
|
-40 to 75 °C (-40 to 167 °F)
|
Not Applicable
|
|
0 to 1 psi
|
Gauge
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 75 °C (-40 to 167 °F)
|
Not Applicable
|
|
0 to 5 psi
|
Gauge
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 75 °C (-40 to 167 °F)
|
Not Applicable
|
|
0 to 15 psi
|
Absolute
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 75 °C (-40 to 167 °F)
|
Not Applicable
|
|
0 to 15 psi
|
Gauge
|
< 0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 75 °C (-40 to 167 °F)
|
Not Applicable
|
The PX51 series are heavy duty, all stainless steel pressure transducers for harsh environments and pressure ranges up to 30,000 psi.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 10000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Digital
|
USB
|
1/4"
|
High Pressure F-250-C
|
Cable
|
-40 to 85 °C (-40 to 185 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 104 °C (-40 to 220 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 104 °C (-40 to 220 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 104 °C (-40 to 220 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-40 to 104 °C (-40 to 220 °F)
|
Not Applicable
|
The PX880 series is FM and CSA approved for hazardous industrial locations and ideal for use with corrosive media and in hazardous environments. Available from 15 to 3,000 psi.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 15 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Female
|
Conduit
|
-40 to 100 °C (-40 to 212 °F)
|
|
0 to 1000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Female
|
Conduit
|
-40 to 100 °C (-40 to 212 °F)
|
|
0 to 3,000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Female
|
Conduit
|
-40 to 100 °C (-40 to 212 °F)
|
|
0 to 5000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Female
|
Conduit
|
-40 to 100 °C (-40 to 212 °F)
|
|
0 to 30 psi
|
Gauge
|
0.1% to 0.25%
|
±0.2%
|
Current
|
4 to 20 mA
|
1/2"
|
NPT Female
|
Conduit
|
-40 to 100 °C (-40 to 212 °F)
|
The PX2760 is an electric barometer with a rugged capacitive design, fast response time, and 3 field selectable ranges in one unit.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
800 to 1,100 mbar
|
Barometric
|
0.1% to 0.25%
|
±0.25%
|
Voltage
|
0.1 to 5.1 Vdc
|
1/8"
|
Barbed Fitting
|
Cable
|
-20 to 80 °C (-4 to 176 °F)
|
|
0 to 20 psi
|
Absolute
|
0.1% to 0.25%
|
±0.25%
|
Voltage
|
0.1 to 5.1 Vdc
|
1/8"
|
Barbed Fitting
|
Cable
|
-20 to 80 °C (-4 to 176 °F)
|
|
600 to 1,060 mbar
|
Barometric
|
0.1% to 0.25%
|
±0.25%
|
Voltage
|
0.1 to 5.1 Vdc
|
1/8"
|
Barbed Fitting
|
Cable
|
-20 to 80 °C (-4 to 176 °F)
|
PX633 series submersible transmitters are watertight, and temperature error compensation for high precision measurements in most underwater applications.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 5 psi
|
Gauge
|
> 0.25%
|
±0.5%
|
Current
|
4 to 20 mA
|
Submersible
|
Submersible Cable
|
-10 to 70 °C (14 to 158 °F)
|
Surge Protection
|
|
0 to 3 psi
|
Gauge
|
< 0.1%
|
±0.1%
|
Current
|
4 to 20 mA
|
Submersible
|
Submersible Cable
|
-10 to 70 °C (14 to 158 °F)
|
Surge Protection
|
|
0 to 5 psi
|
Gauge
|
< 0.1%
|
±0.1%
|
Current
|
4 to 20 mA
|
Submersible
|
Submersible Cable
|
-10 to 70 °C (14 to 158 °F)
|
Surge Protection
|
|
0 to 15 psi
|
Gauge
|
< 0.1%
|
±0.1%
|
Current
|
4 to 20 mA
|
Submersible
|
Submersible Cable
|
-10 to 70 °C (14 to 158 °F)
|
Surge Protection
|
|
0 to 30 psi
|
Gauge
|
< 0.1%
|
±0.1%
|
Current
|
4 to 20 mA
|
Submersible
|
Submersible Cable
|
-10 to 70 °C (14 to 158 °F)
|
Surge Protection
|
Product Number | Pressure Range | Pressure Type | Accuracy Class | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Accuracy Value | Housing | Options |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 25 psi
|
Differential
|
> 0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
1/2" female NPT conduit
|
-18 to 93°C (0 to 200°F)
|
±0.5%
|
None
|
None
|
|
0 to 10 psi
|
Differential
|
> 0.25%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
1/2" female NPT conduit
|
-18 to 93°C (0 to 200°F)
|
±0.5%
|
None
|
None
|
|
0 to 10 psi
|
Differential
|
> 0.25%
|
Selectable
|
0 to 5, 1 to 5, 0 to 10, or 2 to 10 Vdc
|
1/4"
|
NPT Female
|
1/2" female NPT conduit
|
-18 to 93°C (0 to 200°F)
|
±0.5%
|
None
|
None
|
|
0 to 10 PSID
|
Differential
|
None
|
4-20mA
|
1/2" Female NPT Conduit
|
1/4" NPT Female
|
None
|
None
|
None
|
±0.5%
|
Conduit
|
20 Ft. Shielded Cable
|
|
0 to 10 PSID
|
Differential
|
None
|
4-20mA
|
1/2" Female NPT Conduit
|
1/4" NPT Female
|
None
|
None
|
None
|
±0.5%
|
Conduit
|
20 Ft. Armored Cable
|
The PX165 series measures differential pressure in low and ultra low ranges, down to 0.25 inches of water. Their compact size is also ideal for board mounted applications.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
-5 to 5 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
0.5 to 4.5 Vdc
|
3/32"
|
Tube
|
Pins
|
-20 to 60 °C (-4 to 140 °F)
|
PCB Mountable
|
|
-1 to 1 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
0.5 to 4.5 Vdc
|
3/32"
|
Tube
|
Pins
|
-20 to 60 °C (-4 to 140 °F)
|
PCB Mountable
|
|
0 to 1 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
0.5 to 4.5 Vdc
|
3/32"
|
Tube
|
Pins
|
-20 to 60 °C (-4 to 140 °F)
|
PCB Mountable
|
|
-2 to 2 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
0.5 to 4.5 Vdc
|
3/32"
|
Tube
|
Pins
|
-20 to 60 °C (-4 to 140 °F)
|
PCB Mountable
|
|
0 to 2 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Ratiometric mV/V
|
0.5 to 4.5 Vdc
|
3/32"
|
Tube
|
Pins
|
-20 to 60 °C (-4 to 140 °F)
|
PCB Mountable
|
The PX653 series are well suited for use in clean rooms, HVAC systems, and laboratory fume hoods. They have a 4-20 mA or 1-5 V output in ranges from ± 0.05 to ± 50 inH2O.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
-2.5 to 2.5 inH2O
|
Differential
|
> 0.25%
|
±0.3%
|
Current
|
4 to 20 mA
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-29 to 72 °C (-20 to 160 °F)
|
|
0 to 1 inH2O
|
Differential
|
> 0.25%
|
±0.3%
|
Current
|
4 to 20 mA
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-29 to 72 °C (-20 to 160 °F)
|
|
0 to 2 inH2O
|
Differential
|
> 0.25%
|
±0.3%
|
Current
|
4 to 20 mA
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-29 to 72 °C (-20 to 160 °F)
|
|
0 to 3 inH2O
|
Differential
|
> 0.25%
|
±0.3%
|
Current
|
4 to 20 mA
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-29 to 72 °C (-20 to 160 °F)
|
|
0 to 5 inH2O
|
Differential
|
> 0.25%
|
±0.3%
|
Current
|
4 to 20 mA
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-29 to 72 °C (-20 to 160 °F)
|
The PX2650 series is an economical solution to measure dry gasses in building management, HVAC, or clean rooms with a voltage output in low ranges from ± 0.25 to ±50 inH2O.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 2 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Voltage
|
0.2 to 5.2 Vdc
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-18 to 65 °C (0 to 149 °F)
|
|
0 to 10 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Voltage
|
0.2 to 5.2 Vdc
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-18 to 65 °C (0 to 149 °F)
|
|
-1 to 1 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Voltage
|
0.2 to 5.2 Vdc
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-18 to 65 °C (0 to 149 °F)
|
|
0 to 25 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Voltage
|
0.2 to 5.2 Vdc
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-18 to 65 °C (0 to 149 °F)
|
|
-2 to 2 inH2O
|
Differential
|
> 0.25%
|
±1%
|
Voltage
|
0.2 to 5.2 Vdc
|
1/4"
|
Barbed Fitting
|
Terminal Block
|
-18 to 65 °C (0 to 149 °F)
|
MM Series custom transducers allow for over 1-million possible combinations of parameters such as pressure type, range, unit, material, output, accuracy, fitting, temperature compensation range, and electrical termination.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 170 mbar
|
Compound Gauge
|
0.1% to 0.25%
|
±0.20%
|
Current
|
4 to 20 mA
|
1/4"
|
BSPP Female
|
Mini DIN 43650 C
|
-10 to 93 °C (0 to 200 °F)
|
CE, Max Thermal Shift ±0.5% Z±0.5%S
|
|
880 to 1100 mbar
|
Barometric
|
<0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Conduit
|
-6 to 60 °C (20 to 140 °F)
|
Max Thermal Shift ±0.9% Z±0.6%S
|
|
880 to 1100 mbar
|
Barometric
|
<0.1%
|
±0.08%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Cable
|
-40 to 100°C (-40 to 220 °F)
|
Max Thermal Shift ±0.8% Z±0.3%S
|
|
26 to 32 inHg
|
Barometric
|
<0.1%
|
±0.05%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Conduit
|
-6 to 60 °C (20 to 140 °F)
|
Max Thermal Shift ±0.8% Z±0.3%S
|
|
26 to 32 inHg
|
Barometric
|
<0.1%
|
±0.05%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
M12
|
-40 to 100°C (-40 to 220 °F)
|
Max Thermal Shift ±0.8% Z±0.3%S
|
The PX91 series withstand temperatures up to 218°C(425°F) and are available in pressure ranges up to 200,000 psi. Designed for use in high temperature test chambers.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 5000 psi
|
Gauge
|
> 0.25%
|
±0.4%
|
Ratiometric mV/V
|
1 mV/V
|
1/2"
|
High Pressure NPSM
|
Cable
|
-56 to 204 °C (-70 to 400 °F)
|
Not Applicable
|
|
0 to 5000 psi
|
Gauge
|
> 0.25%
|
±0.4%
|
Current
|
4 to 20 mA
|
1/2"
|
High Pressure NPSM
|
Cable
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
|
0 to 5000 psi
|
Sealed Gauge
|
> 0.25%
|
±0.4%
|
Ratiometric mV/V
|
1 mV/V
|
1/2"
|
High Pressure NPSM
|
Cable
|
-56 to 204 °C (-70 to 400 °F)
|
Not Applicable
|
|
0 to 5000 psi
|
Gauge
|
> 0.25%
|
±0.4%
|
Current
|
4 to 20 mA
|
1/2"
|
High Pressure NPSM
|
Conduit
|
-46 to 121 °C (-50 to 250 °F)
|
Lightening Protected Amplifier Box
|
|
0 to 10000 psi
|
Gauge
|
> 0.25%
|
±0.4%
|
Current
|
4 to 20 mA
|
1/2"
|
High Pressure NPSM
|
Cable
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
The PX5500 series are stable to 0.1% of FSO over an 18-month period and have 10-year MTBF rate to withstand rigorous testing and demanding applications.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 1000 psi
|
Absolute
|
0.1% to 0.25%
|
±0.15%
|
Current
|
4 to 20 mA
|
1/8"
|
NPT Female
|
MIL-26482-I 10-6P
|
-54 to 121 °C (-65 to 250 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.15%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
NPT Male
|
Cable
|
-54 to 150 °C (-65 to 300 °F)
|
Not Applicable
|
|
0 to 3,000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.15%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
NPT Male
|
Cable
|
-54 to 150 °C (-65 to 300 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Absolute
|
0.1% to 0.25%
|
±0.15%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
MIL-26482-I 10-6P
|
-54 to 121 °C (-65 to 250 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.15%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
MIL-26482-I 10-6P
|
-54 to 121 °C (-65 to 250 °F)
|
Not Applicable
|
The PX01 series have a high ±0.09% accuracy and rugged, hermetically sealed housing that makes them suitable for harsh industrial and hydraulic environments.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
0 to 1000 psi
|
Gauge
|
< 0.1%
|
±0.09%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Gauge
|
< 0.1%
|
±0.09%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
MIL-26482-I 10-6P
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Gauge
|
< 0.1%
|
±0.09%
|
Ratiometric mV/V
|
3 mV/V
|
1/4"
|
NPT Male
|
MIL-26482-I 10-6P
|
-73 to 163 °C (-100 to 325 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Absolute
|
< 0.1%
|
±0.09%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
MIL-26482-I 10-6P
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Gauge
|
< 0.1%
|
±0.09%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
MIL-26482-I 10-6P
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
The PX654 series are well suited for use in clean rooms, HVAC systems, and laboratory fume hoods. They have a 4-20 mA or 1-5 V output in ranges from ± 0.05 to +± 100 inH2O.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range |
---|---|---|---|---|---|---|---|---|---|---|
|
0 to 1 inH2O
|
Differential
|
0.1% to 0.25%
|
±0.15%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-29 to 85 °C (-20 to 185 °F)
|
|
0 to 2 inH2O
|
Differential
|
0.1% to 0.25%
|
±0.15%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-29 to 85 °C (-20 to 185 °F)
|
|
0 to 3 inH2O
|
Differential
|
0.1% to 0.25%
|
±0.15%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-29 to 85 °C (-20 to 185 °F)
|
|
0 to 5 inH2O
|
Differential
|
0.1% to 0.25%
|
±0.15%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-29 to 85 °C (-20 to 185 °F)
|
|
0 to 1 inH2O
|
Differential
|
> 0.25%
|
±0.3%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Female
|
Conduit
|
-29 to 85 °C (-20 to 185 °F)
|
The PX02 series has an accessible shunt resistor for quick, convenient calibration checks along with a hermetically sealed double diaphragm for harsh environments.
Product Number | Pressure Range | Pressure Type | Accuracy Class | Accuracy Value(compensated range) | Output Signal | Electrical Output | Pressure Port Size | Pressure Port Type | Connection/Termination | Operating Temperature Range | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
16 to 32 inHg
|
Barometric
|
0.1% to 0.25%
|
±0.19%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
|
0 to 1000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.19%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
|
26 to 32 inHg
|
Barometric
|
0.1% to 0.25%
|
±0.19%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
|
0 to 2,000 psi
|
Sealed Gauge
|
0.1% to 0.25%
|
±0.19%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|
|
0 to 5000 psi
|
Gauge
|
0.1% to 0.25%
|
±0.19%
|
Current
|
4 to 20 mA
|
1/4"
|
NPT Male
|
Cable
|
-46 to 121 °C (-50 to 250 °F)
|
Not Applicable
|