Call us at 1-888-826-6342
Fast response thermocouples mounted in a polyimide carrier with a self-adhesive backing for easily measuring surface temperatures up to 260°C. Resistant to oil and chemicals.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Probe Diameter | Minimum Temperature Measurement | Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
T
|
-17 to 150°C (0 to 302°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Not Applicable
|
40 in
|
Not Applicable
|
|
Thermocouple
|
J
|
-17 to 260°C (0 to 500°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Not Applicable
|
40 in
|
Not Applicable
|
|
Thermocouple
|
K
|
-17 to 260°C (0 to 500°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Not Applicable
|
36 in
|
Not Applicable
|
|
Thermocouple
|
J
|
-17 to 260°C (0 to 500°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
1 m
|
IEC
|
Not Applicable
|
40 in
|
IEC Color Code
|
|
Thermocouple
|
K
|
-17 to 260°C (0 to 500°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
1 m
|
IEC
|
Not Applicable
|
40 in
|
Not Applicable
|
General use fast response thermocouples mounted in glass tape & polyimide with a self-adhesive backing for easily measuring surface temperatures up to 175°C.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Mounting Style | Probe Diameter | Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
T
|
0 to 150°C (32 to 302°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Standard
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 175°C (32 to 350°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Standard
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
J
|
0 to 175°C (32 to 350°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Standard
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
K
|
0 to 175°C (32 to 350°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Standard
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 175°C (32 to 350°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
80 in
|
ANSI (Standard)
|
Standard
|
Not Applicable
|
Not Applicable
|
General use fast response RTDs mounted in glass tape & polyimide with a self-adhesive backing for easily measuring surface temperatures up to 290°C. Class B Accuracy.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Number Of Wires | Cable Insulation | Termination Connection Type | Cable Length | Mounting Style | Maximum Temperature Measurement | Minimum Temperature Measurement |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.3°C
|
3
|
PFA
|
Stripped Leads
|
40 in
|
Class B DIN Platinum
|
260°C (500°F)
|
-73°C
|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.3°C
|
4
|
PFA
|
Stripped Leads
|
40 in
|
Class B DIN Platinum
|
260°C (500°F)
|
-73°C
|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.3°C
|
3
|
PFA
|
Stripped Leads
|
80 in
|
Class B DIN Platinum
|
260°C (500°F)
|
-73°C
|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.3°C
|
3
|
PFA
|
Stripped Leads
|
120 in
|
Class B DIN Platinum
|
260°C (500°F)
|
-73°C
|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.3°C
|
3
|
PFA
|
3-Prong Miniature Connector
|
40 in
|
Class B DIN Platinum
|
260°C (500°F)
|
-73°C
|
General use fast response RTDs mounted in glass tape & polyimide with a self-adhesive backing for easily measuring surface temperatures up to 290°C. Class A Accuracy.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Number Of Wires | Cable Insulation | Termination Connection Type | Cable Length | Mounting Style | Maximum Temperature Measurement | Minimum Temperature Measurement |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.15°C
|
3
|
PFA
|
Stripped Leads
|
120 in
|
Class A DIN Platinum
|
260°C (500°F)
|
-73°C
|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.15°C
|
3
|
PFA
|
Stripped Leads
|
40 in
|
Class A DIN Platinum
|
260°C (500°F)
|
-73°C
|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.15°C
|
4
|
PFA
|
Stripped Leads
|
40 in
|
Class A DIN Platinum
|
260°C (500°F)
|
-73°C
|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.15°C
|
3
|
PFA
|
Stripped Leads
|
80 in
|
Class A DIN Platinum
|
260°C (500°F)
|
-73°C
|
|
RTD
|
-73°C to 260°C (-100°F to 500°F)
|
Self-Adhesive
|
100 Ω
|
±0.15°C
|
3
|
PFA with Stainless Steel Overbraid
|
Stripped Leads
|
40 in
|
Class A DIN Platinum
|
260°C (500°F)
|
-73°C
|
The RTD-831 series is designed for use as a surface sensor. It has an aluminum housing for fast transfer of heat to/from the sensing element. Choice of either 100 ohm or 1000 ohm RTD element.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Number of Wires | Cable Insulation | Termination Connection Type | Cable Length | Additional Features |
---|---|---|---|---|---|---|---|---|---|---|
![]() |
RTD
|
-60 to 230°C (-76 to 446°F)
|
Bolt-on
|
100 Ω
|
Class “A” accuracy per IEC 60751
|
3
|
PFA
|
Stripped Ends
|
1 m
|
#3, #4 Screw Size
|
![]() |
RTD
|
-60 to 230°C (-76 to 446°F)
|
Bolt-on
|
100 Ω
|
Class “A” accuracy per IEC 60751
|
3
|
PFA
|
Terminal Lugs
|
1 m
|
#3, #4 Screw Size
|
![]() |
RTD
|
-60 to 230°C (-76 to 446°F)
|
Bolt-on
|
100 Ω
|
Class “A” accuracy per IEC 60751
|
3
|
PFA
|
3-Prong Miniature Connector
|
1 m
|
#3, #4 Screw Size
|
![]() |
RTD
|
-60 to 230°C (-76 to 446°F)
|
Bolt-on
|
100 Ω
|
Class “A” accuracy per IEC 60751
|
3
|
PFA
|
3-Prong Standard Connector
|
1 m
|
#3, #4 Screw Size
|
![]() |
RTD
|
-60 to 230°C (-76 to 446°F)
|
Bolt-on
|
100 Ω
|
Class “B” accuracy per IEC 60751
|
3
|
PFA
|
Stripped Ends
|
1 m
|
#3, #4 Screw Size
|
Thin film thermocouples with extremely fast response times that can be glued, epoxied, or cemented onto surfaces for short or long-term temperature measurement.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Mounting Style | Probe Diameter | Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 260°C (32 to 500°F)
|
Cement-On
|
Fiberglass
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Cement-On
|
Not Applicable
|
Style 3, Welded Bead
|
|
Thermocouple
|
E
|
0 to 260°C (32 to 500°F)
|
Cement-On
|
Fiberglass
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Cement-On
|
Not Applicable
|
Style 1, Butt Weld
|
|
Thermocouple
|
K
|
0 to 260°C (32 to 500°F)
|
Cement-On
|
Fiberglass
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Cement-On
|
Not Applicable
|
Style 1, Butt Weld
|
|
Thermocouple
|
T
|
0 to 150°C (32 to 300°F)
|
Cement-On
|
Fiberglass
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Cement-On
|
Not Applicable
|
Style 1, Butt Weld
|
|
Thermocouple
|
E
|
0 to 425°C (32 to 800°F)
|
Cement-On
|
Thermocouple Alloy
|
Stripped Leads
|
6 in
|
ANSI (Standard)
|
Cement-On
|
Not Applicable
|
Style 2, Butt Weld
|
Spring-loaded thermocouple probes with a powerful single or dual 12lb pull magnet ideal for easily mounting to and measuring the surface temperature of ferrous metals.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Mounting Style | Probe Diameter | Minimum Temperature Measurement | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 370°C (32 to 700°F)
|
Magnetic Mount Single
|
Stainless Steel Overbraiding
|
Miniature Connector
|
40 in
|
ANSI (Standard)
|
Single Magnet Probe
|
Not Applicable
|
40 in
|
Spring Loaded thermocouple
|
|
Thermocouple
|
E
|
0 to 370°C (32 to 700°F)
|
Magnetic Mount Single
|
Not Applicable
|
Miniature Connector
|
40 in
|
ANSI (Standard)
|
Single Magnet Probe
|
Not Applicable
|
40 in
|
Spring Loaded thermocouple
|
|
Thermocouple
|
J
|
0 to 370°C (32 to 700°F)
|
Magnetic Mount Single
|
Stainless Steel Overbraiding
|
Miniature Connector
|
40 in
|
ANSI (Standard)
|
Single Magnet Probe
|
Not Applicable
|
40 in
|
Spring Loaded thermocouple
|
|
Thermocouple
|
T
|
0 to 370°C (32 to 700°F)
|
Magnetic Mount Single
|
Stainless Steel Overbraiding
|
Miniature Connector with Cable Clamp
|
40 in
|
ANSI (Standard)
|
Single Magnet Probe
|
Not Applicable
|
40 in
|
Spring Loaded thermocouple
|
|
Thermocouple
|
E
|
0 to 370°C (32 to 700°F)
|
Magnetic Mount Dual
|
Stainless Steel Overbraiding
|
Miniature Connector
|
40 in
|
ANSI (Standard)
|
Dual Magnet Probe
|
Not Applicable
|
40 in
|
Spring Loaded thermocouple
|
Thermistor sensors encapsulated in a small aluminum heat-conductive housing with a mounting hole. Ideal for bolting to flat surfaces to measure temperatures up to 100°C.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Cable Insulation | Termination Connection Type | Cable Length |
---|---|---|---|---|---|---|---|---|
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Bolt-On
|
3000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
12 in
|
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Bolt-On
|
10,000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
12 in
|
Bolt-on or bolt-mount RTD sensors encapsulated in a small stainless steel #8-32 or M4 threaded housing. Ideal for bolting to objects to measure temperatures up to 230°C.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Number Of Wires | Cable Insulation | Termination Connection Type | Cable Length | Additional Features | Mounting Style | Maximum Temperature Measurement | Minimum Temperature Measurement |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-60 to 230°C (-76 to 446°F)
|
Threaded Mounting
|
100 Ω
|
±0.15°C
|
3
|
PFA
|
3-Prong Miniature Connector
|
40 in
|
None
|
Class A DIN Platinum
|
230°C (446°F)
|
-60°C (-76°F)
|
|
RTD
|
-60 to 230°C (-76 to 446°F)
|
Threaded Mounting
|
100 Ω
|
±0.15°C
|
3
|
PFA
|
3-Prong Miniature Connector
|
40 in
|
M4 threaded tip
|
Class A DIN Platinum
|
230°C (446°F)
|
-60°C (-76°F)
|
|
RTD
|
-60 to 230°C (-76 to 446°F)
|
Threaded Mounting
|
100 Ω
|
±0.15°C
|
3
|
PFA
|
3-Prong Full-Size Connector
|
40 in
|
#8-32 threaded tip
|
Class A DIN Platinum
|
230°C (446°F)
|
-60°C (-76°F)
|
Fast response thermocouples mounted in glass tape & polyimide with a self-adhesive backing and fiberglass lead-wires for easily measuring surface temperatures up to 315°C.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Mounting Style | Probe Diameter | Features |
---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
E
|
0 to 315°C (32 to 600°F)
|
Surface
|
Fiberglass
|
Stripped Leads
|
40 in
|
ANSI (standard)
|
Standard
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
J
|
0 to 315°C (32 to 600°F)
|
Surface
|
Fiberglass
|
Stripped Leads
|
40 in
|
ANSI (standard)
|
Standard
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
K
|
0 to 315°C (32 to 600°F)
|
Surface
|
Fiberglass
|
Stripped Leads
|
40 in
|
ANSI (standard)
|
Standard
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
T
|
0 to 150°C (32 to 302°F)
|
Surface
|
Fiberglass
|
Stripped Leads
|
40 in
|
ANSI (standard)
|
Standard
|
Not Applicable
|
Not Applicable
|
|
Thermocouple
|
J
|
0 to 315°C (32 to 600°F)
|
Surface
|
Fiberglass
|
Stripped Leads
|
1 m
|
IEC
|
Standard
|
Not Applicable
|
IEC standard
|
General use thermocouples molded into silicone rubber with self-adhesive backing for easily measuring the temperatures of curved or flat surfaces up to 200°C.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Additional Features | Mounting Style | Probe Diameter | Probe Length | Minimum Temperature Measurement | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
120 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Curved Surface Mounting
|
Not Applicable
|
Not Applicable
|
120 in
|
Foil backing for fast response
|
|
Thermocouple
|
K
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Curved Surface Mounting
|
Not Applicable
|
Not Applicable
|
40 in
|
Foil backing for fast response
|
|
Thermocouple
|
T
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Curved Surface Mounting
|
Not Applicable
|
Not Applicable
|
36 in
|
Foil backing for fast response
|
|
Thermocouple
|
J
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Flat Surface Mounting
|
Flat Surface Mounting
|
Not Applicable
|
Not Applicable
|
36 in
|
Foil backing for fast response
|
|
Thermocouple
|
K
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
40 in
|
ANSI (Standard)
|
Flat Surface Mounting
|
Flat Surface Mounting
|
Not Applicable
|
Not Applicable
|
40 in
|
Foil backing for fast response
|
The ON-931 series is ideal for surface sensing. It has an aluminum housing for fast transfer of heat to the sensing element. Choice of 2252, 3000, 5000, 10,000 or 30,000 ohm thermistor element.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Cable Insulation | Termination Connection Type | Cable Length |
---|---|---|---|---|---|---|---|---|
![]() |
Thermistor
|
-80 to 100°C (-112 to 212°F)
|
Bolt-On
|
2252 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
40 in
|
![]() |
Thermistor
|
-80 to 100°C (-112 to 212°F)
|
Bolt-On
|
3000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
40 in
|
![]() |
Thermistor
|
-80 to 100°C (-112 to 212°F)
|
Bolt-On
|
3000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
72 in
|
![]() |
Thermistor
|
-80 to 100°C (-112 to 212°F)
|
Bolt-On
|
10,000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
40 in
|
![]() |
Thermistor
|
-80 to 100°C (-112 to 212°F)
|
Bolt-On
|
10,000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
48 in
|
Epoxy encapsulated RTD sensors in small stainless steel disc-shaped housings ideal for measuring surface temperatures up to 230°C. Glue, epoxy, or cement onto a flat surface.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Number Of Wires | Cable Insulation | Termination Connection Type | Cable Length | Mounting Style | Maximum Temperature Measurement | Minimum Temperature Measurement |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
-60 to 230°C (-76 to 446°F)
|
Flat Disc
|
100 Ω
|
±0.15°C
|
3
|
PFA
|
Miniature Connector
|
1 m
|
Class A DIN Platinum
|
230°C (450°F)
|
-50 {C} (-58 {F})
|
Bolt-on or bolt-mount Thermistor sensors encapsulated in a small stainless steel #8-32 or M4 threaded housing. Ideal for bolting to objects to measure temperatures up to 100°C.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Cable Insulation | Termination Connection Type | Cable Length |
---|---|---|---|---|---|---|---|---|
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Threaded Mounting
|
2252 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
12 in
|
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Threaded Mounting
|
3000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
12 in
|
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Threaded Mounting
|
10,000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
12 in
|
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Threaded Mounting
|
5000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
12 in
|
|
Thermistor
|
0 to 100°C (32 to 212°F)
|
Threaded Mounting
|
30,000 Ω
|
±0.2°C
|
PFA
|
Stripped Leads
|
12 in
|
Clamp-type thermocouple sensor ideal for easily measuring the surface temperature of pipes ranging from 0.25" to 1.4" in diameter. Use with a handheld temperature meter.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard |
---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
-50 to 200°C (-58 to 392°F)
|
Pipe Clamp
|
Nylon with Glass Fiber Filling
|
Miniature Connector
|
36 in
|
ANSI (Standard)
|
Thermocouples with mounted inside a stainless steel washer housing. Easily bolt to a variety of surfaces to measure temperature. Available in type J, K, T, or E calibrations.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Additional Features | Mounting Style | Probe Diameter | Minimum Temperature Measurement | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 260°C (32 to 500°F)
|
Bolt-On
|
PFA
|
Miniature Connector
|
24 in
|
ANSI (Standard)
|
#10 Screw Size
|
#10 Screw Size
|
#10 or M4.5 Srew
|
24 in
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 482°C (32 to 900°F)
|
Bolt-On
|
Fiberglass
|
Stripped Leads
|
12 in
|
ANSI (Standard)
|
#6 Screw Size
|
#6 Screw Size
|
# 6 or M3.5 Screw
|
12 in
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 482°C (32 to 900°F)
|
Bolt-On
|
Fiberglass
|
Stripped Leads
|
24 in
|
ANSI (Standard)
|
#6 Screw Size
|
#6 Screw Size
|
# 6 or M3.5 Screw
|
24 in
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 482°C (32 to 900°F)
|
Bolt-On
|
Fiberglass
|
Stripped Leads
|
36 in
|
ANSI (Standard)
|
#6 Screw Size
|
#6 Screw Size
|
# 6 or M3.5 Screw
|
36 in
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 482°C (32 to 900°F)
|
Bolt-On
|
Fiberglass
|
Stripped Leads
|
60 in
|
ANSI (Standard)
|
#6 Screw Size
|
#6 Screw Size
|
# 6 or M3.5 Screw
|
60 in
|
Not Applicable
|
High-temperature abrasion resistant thermocouples with Inconel Overbraiding for measuring temperatures up to 1038°C in rugged applications like profiling ovens and furnaces.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Mounting Style | Probe Diameter | Overbraiding and Fitting | Features |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 980°C (32 to 1800°F)
|
Bolt-On
|
Silica with Inconel Overbraid
|
Stripped Leads
|
120 in
|
ANSI (Standard)
|
Not Applicable
|
# 6 or M3.5 Screw
|
Inconel® 600
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 540°C (32 to 1000°F)
|
Bolt-On
|
Nextel with Inconel Overbraid
|
Ceramic Beaded Leads with Spade Lugs
|
96 in
|
ANSI (Standard)
|
Ceramic Beaded leads
|
# 6 or M3.5 Screw
|
Inconel® 600
|
Bolted to surface
|
|
Thermocouple
|
E
|
0 to 540°C (32 to 1000°F)
|
Bolt-On
|
Nextel with Inconel Overbraid
|
Standard Connector
|
96 in
|
ANSI (Standard)
|
Not Applicable
|
# 6 or M3.5 Screw
|
Inconel® 600
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 540°C (32 to 1000°F)
|
Bolt-On
|
Nextel with Inconel Overbraid
|
Ceramic Standard Connector
|
96 in
|
ANSI (Standard)
|
Not Applicable
|
# 6 or M3.5 Screw
|
Inconel® 600
|
Not Applicable
|
|
Thermocouple
|
E
|
0 to 540°C (32 to 1000°F)
|
Bolt-On
|
Nextel with Inconel Overbraid
|
Spade Lugs
|
96 in
|
ANSI (Standard)
|
Not Applicable
|
# 6 or M3.5 Screw
|
Inconel® 600
|
Not Applicable
|
Spring-loaded thermocouple element in a short housing that plugs directly into most handheld thermometers for easy ad-hoc surface temperature measurements up to 218°C.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Termination Connection Type | Color Code Standard | Probe Diameter | Features |
---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
K
|
0 to 218°C (32 to 425°F)
|
Handheld Meter
|
Miniature Connector
|
ANSI (Standard)
|
Not Applicable
|
Not Applicable
|
The SAP series thermocouple sensors come in curved and flat styles. An adhesive pad holds the sensor onto the measuring surface. These come in types J, K, T and E.
Product Number | Category | Thermocouple Type | Process Temperature Range | Sensor Application | Cable Insulation | Termination Connection Type | Cable Length | Color Code Standard | Mounting Style | Features |
---|---|---|---|---|---|---|---|---|---|---|
|
Thermocouple
|
T
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
36 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Thin backing for fast response
|
|
Thermocouple
|
E
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
36 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Thin backing for fast response
|
|
Thermocouple
|
E
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
72 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Thin backing for fast response
|
|
Thermocouple
|
J
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
36 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Thin backing for fast response
|
|
Thermocouple
|
J
|
-50 to 200°C (-58 to 392°F)
|
Self-Adhesive
|
PFA
|
Stripped Leads
|
72 in
|
ANSI (Standard)
|
Curved Surface Mounting
|
Thin backing for fast response
|
Spring-loaded RTD probes with a powerful 13lb pull magnetic housing ideal for easily mounting to and measuring the surface temperature of ferrous metals up to 400°C.
Product Number | Category | Process Temperature Range | Sensor Application | Nominal Resistance | Accuracy | Number Of Wires | Cable Insulation | Termination Connection Type | Cable Length | Additional Features | Mounting Style | Maximum Temperature Measurement |
---|---|---|---|---|---|---|---|---|---|---|---|---|
|
RTD
|
0 to 400°C (32 to 753°F)
|
Magnetic Mount
|
100 Ω
|
Class A per IEC60751
|
3
|
Fiberglass with Stainless Steel Overbraid
|
Stripped Leads
|
3 m
|
Fiberglass Cable with SST Overbraid
|
Magnetic Mount
|
400°C
|
|
RTD
|
0 to 400°C (32 to 753°F)
|
Magnetic Mount
|
100 Ω
|
Class A per IEC60751
|
3
|
Fiberglass
|
Stripped Leads
|
1 m
|
Fiberglass Cable
|
Magnetic Mount
|
400°C
|
|
RTD
|
0 to 400°C (32 to 753°F)
|
Magnetic Mount
|
100 Ω
|
Class A per IEC60751
|
3
|
Fiberglass
|
Stripped Leads
|
3 m
|
Fiberglass Cable
|
Magnetic Mount
|
400°C
|
|
RTD
|
0 to 100°C (32 to 212°F)
|
Magnetic Mount
|
100 Ω
|
Class A per IEC60751
|
3
|
PVC
|
Stripped Leads
|
1 m
|
PVC Cable
|
Magnetic Mount
|
100°C
|
|
RTD
|
0 to 100°C (32 to 212°F)
|
Magnetic Mount
|
100 Ω
|
Class A per IEC60751
|
3
|
PVC
|
Stripped Leads
|
3 m
|
PVC Cable
|
Magnetic Mount
|
100°C
|